Repair of a Bilobed Descending Aortic Aneurysm

By Daniel J. Torrent, MD, and Michael C. Stoner, MD, RVT, FACS
 

An 80-year-old woman with multiple medical comorbidities, including chronic obstructive pulmonary disease requiring home oxygen, was being followed for a bilobed descending aortic aneurysm. The thoracic portion was saccular and increased in size on serial imaging to 6 cm. Her comorbidities prohibited open repair, and on CT scan, it was noted that her iliac arteries were very bilaterally tortuous, making access difficult.

The patient was admitted for elective repair and taken to the operating room. Percutaneous access was achieved through the right common femoral artery. A left common femoral artery cutdown was performed for access on that side. Catheters were advanced through the femoral arteries into the aortic arch, and systemic heparin was administered. Angiography was performed to show the saccular aneurysm (Figure 1). A 42 X 150 mm Relay device (Bolton Medical, Inc., Sunrise, FL) was selected based on prior measurements. Initially, attempts were made to pass the graft up a Lunderquist wire through the left common femoral artery. Because of her very tortuous iliac artery (Figure 2), the graft could not be passed even after using an Amplatz buddy wire to help straighten the course.

A right femoral cutdown around the 5 F sheath was then performed, and the device was passed through the femoral artery and a very tortuous right iliac artery over a wire. With the device in place, a thoracic aortic angiogram showed that the graft was in a good location, and the stent was deployed. Completion angiography showed appropriate deployment and opposition against the aortic wall with exclusion of the aneurysm sac (Figure 3). The catheters, wires, and sheaths were removed with fluoroscopic guidance. The arteriotomies were repaired, and the groins were closed in layers.

She was discharged to home on postoperative day 3 after weaning back to her home oxygen requirements.

At 1-year follow-up, the patient was doing well. She was eating and getting exercise. A CT of her chest showed that the stent was in position and patent without endoleak. The aneurysm shrank to 4.6 cm with a 37 mm neck proximally (46 mm distally).

The design of the Relay graft facilitates advancement through tortuous iliac arteries. Device trackability was key in facilitation of endovascular repair.

Daniel J. Torrent, MD, is a surgical resident with East Carolina University, Brody School of Medicine, Department of Surgery in Greenville, North Carolina. He has disclosed that he has no financial interests related to this article.

Michael C. Stoner, MD, RVT, FACS, is Chief of Vascular Surgery, University of Rochester Medical Center, Rochester, New York. He has disclosed that he is a speaker for Bolton Medical. Dr. Stoner may be reached at (585) 275-6772; michael_stoner@urmc.rochester.edu.

 

Contact Info

For advertising rates and opportunities, contact:
Craig McChesney
484-581-1816
cmcchesney@bmctoday.com

Stephen Hoerst
484-581-1817
shoerst@bmctoday.com

Charles Philip
484-581-1873
cphillip@bmctoday.com

About Endovascular Today

Endovascular Today is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field. Our Editorial Advisory Board is composed of the top endovascular specialists, including interventional cardiologists, interventional radiologists, vascular surgeons, neurologists, and vascular medicine practitioners, and our publication is read by an audience of more than 22,000 members of the endovascular community.