Inert Technology: Actively Making a Difference in Drug-Eluting Stent Designs

 

QualiMed’s sirolimus-eluting coronary stent is available under CE Mark only and is not approved in the United States.

First-generation drug-eluting stents (DESs) deliver high clinical efficacy at the collateral cost of delayed healing of the stented arterial segment.1 Although DESs and their respective technology have been extensively documented, the discussion has often centered around the type of drug and not necessarily the technical theory behind the stent design.

Figure 1. High-speed bombardment of C+ ions under vacuum onto alloy’s surface.

INERT CARBON TECHNOLOGY

The QualiMed DES is a laser-cut slotted tube with a multicellular design implanted with a unique carbon-ion layer (C+ ion). The carbon-ion layer is incorporated within the metal lattice to a maximum depth of 0.05 µm (Figure 1) and successfully prevents leakage of heavy metal ions such as nickel and molybdenum. This inert carbon technology is a refinement of the alloy surface, which creates a barrier for migrating heavy metal ions. Studies have shown a positive effect on minimizing the rate of restenosis and thrombosis.2

The carbon ions are shot onto the stent’s surface with high energy under vacuum and subsequently penetrate it. This methodology allows the carbon ions to occupy free spaces or displace heavy metal ions such as nickel or molybdenum within the lattice itself. Due to their high electronegative force, surrounding atoms become attracted to the C+ ions. Because carbon is highly biocompatible and easily incorporated, these features are conferred to the alloy.

RAPID POLYMER ABSORPTION

The QualiMed DES is coated in a 5-µm layer of a rapidly absorbing polymer that is designed to resorb within approximately 8 weeks. This rapid absorption of the drug has been shown to help promote earlier neointimal healing as compared to permanent polymer–based DESs3 and may contribute to shortening the duration of dual antiplatelet therapies subsequently following DES implantation.4

Shorter-release kinetics and the biodegradable polymers of DESs have been shown to allow earlier endothelialization expressed by a higher degree of stent strut coverage.5,6

PRELIMINARY DATA

The QualiMed DES is a novel stent with unique material technology and has been shown to have lower rates of stent thrombosis and comparable safety and efficacy statistics (ie, death, myocardial infarction, and target vessel revascularization) compared to treatment groups utilizing durable polymer everolimus-eluting stents (Table 1).7

CONCLUSION

As DES technology continues to evolve, we must be critical not only of eluted drugs provided on the stents, but also the physical properties of the alloys and coatings and their effect on vascular healing.

1. Byrne RA, Sarafoff N, Kastrati A, Schömig A. Drug-eluting stents in percutaneous coronary intervention: a benefit-risk assessment. Drug Saf. 2009;32:749-770.

2. Köster R, Vieluf D, Kiehn M, et al. et al. Nickel and molybdenum contact allergies in patients with coronary in-

stent restenosis [published erratum appears in Lancet. 2001;357:316]. Lancet. 2000;356:1895-1897.

3. Joner M, Nakazawa G, Finn AV, et al. Endothelial cell recovery between comparator polymer-based drug-eluting stents. J Am Coll Cardiol. 2008;52:333-342.

4. Angioplaty.org. Abbott’s XIENCE PRIME™ and Xience V® drug eluting stents receive indication in Europe for minimum 3-month duration of dual anti-platelet therapy [news release]. Published May 15, 2012. http://www.ptca.org/news/2012/0515_XIENCE.html. Accessed November 13, 2017.

5. Templin C, Meyer M, Müller MF, et al. Coronary optical frequency domain imaging (OFDI) for in vivo evaluation of stent healing: comparison with light and electron microscopy. Eur Heart J. 2010;31:1792-1801.

6. Murata A, Wallace-Bradley D, Tellez A, et al. Accuracy of optical coherence tomography in the evaluation of neointimal coverage after stent implantation. JACC Cardiovasc Imaging. 2010;3;76-84.

7. Data on file, QualiMed Innovative Medizinprodukte GmbH.

 

Contact Info

For advertising rates and opportunities, contact:
Craig McChesney
484-581-1816
cmcchesney@bmctoday.com

Stephen Hoerst
484-581-1817
shoerst@bmctoday.com

Charles Philip
484-581-1873
cphillip@bmctoday.com

About Endovascular Today

Endovascular Today is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field. Our Editorial Advisory Board is composed of the top endovascular specialists, including interventional cardiologists, interventional radiologists, vascular surgeons, neurologists, and vascular medicine practitioners, and our publication is read by an audience of more than 22,000 members of the endovascular community.