DEVICE GUIDE > Endograft Fixation Systems

Company Name Product Name Components Sizes Description Footnotes
Medtronic Heli-FX EndoAnchor System EndoAnchor Cassette (contains 10 EndoAnchors) 0.5-mm round wire; 3-mm diameter X 4.5-mm length helix Implants are designed to provide independent transmural sealing and fixation of an endograft to the aortic wall Indicated for use in patients whose endografts have exhibited migration or endoleak, or are at risk of such complications, in whom augmented fixation and/or sealing is required to regain or maintain adequate aneurysm exclusion; the EndoAnchor and Heli-FX System have been evaluated via in vitro testing and determined to be compatible with the Cook Zenith, Gore Excluder, Medtronic AneuRx, Medtronic Endurant, and Medtronic Talent endografts; use with other endografts has not been evaluated
Medtronic Heli-FX EndoAnchor System Ancillary EndoAnchor Cassette (contains five EndoAnchors) 0.5-mm round wire; 3-mm diameter X 4.5-mm length helix Implants are designed to provide independent transmural sealing and fixation of an endograft to the aortic wall Indicated for use in patients whose endografts have exhibited migration or endoleak, or are at risk of such complications, in whom augmented fixation and/or sealing is required to regain or maintain adequate aneurysm exclusion; the EndoAnchor and Heli-FX System have been evaluated via in vitro testing and determined to be compatible with the Cook Zenith, Gore Excluder, Medtronic AneuRx, Medtronic Endurant, and Medtronic Talent endografts; use with other endografts has not been evaluated
Medtronic Heli-FX EndoAnchor System Heli-FX Guide Deflecting tip lengths: 22, 28 mm; 16-F OD; 62-cm working length; 0.035-inch wire compatible Deflecting guide catheter used to position Heli-FX Applier to implant EndoAnchors Indicated for use in patients whose endografts have exhibited migration or endoleak, or are at risk of such complications, in whom augmented fixation and/or sealing is required to regain or maintain adequate aneurysm exclusion; the EndoAnchor and Heli-FX System have been evaluated via in vitro testing and determined to be compatible with the Cook Zenith, Gore Excluder, Medtronic AneuRx, Medtronic Endurant, and Medtronic Talent endografts; use with other endografts has not been evaluated
Medtronic Heli-FX EndoAnchor System Heli-FX Applier 12-F OD; 86-cm working length Battery operated delivery system with two-stage EndoAnchor deployment with repositioning capability Indicated for use in patients whose endografts have exhibited migration or endoleak, or are at risk of such complications, in whom augmented fixation and/or sealing is required to regain or maintain adequate aneurysm exclusion; the EndoAnchor and Heli-FX System have been evaluated via in vitro testing and determined to be compatible with the Cook Zenith, Gore Excluder, Medtronic AneuRx, Medtronic Endurant, and Medtronic Talent endografts; use with other endografts has not been evaluated

Contact Info

For advertising rates and opportunities, contact:
Craig McChesney
484-581-1816
cmcchesney@bmctoday.com

Stephen Hoerst
484-581-1817
shoerst@bmctoday.com

Charles Philip
484-581-1873
cphillip@bmctoday.com

About Endovascular Today

Endovascular Today is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field. Our Editorial Advisory Board is composed of the top endovascular specialists, including interventional cardiologists, interventional radiologists, vascular surgeons, neurologists, and vascular medicine practitioners, and our publication is read by an audience of more than 22,000 members of the endovascular community.