EUROPE DEVICE GUIDE > CTO Crossing Devices

Company Name Product Name Catheter Size (F) Wire Size (inch) Working Length (cm) Minimum Guiding Catheter ID (inch) Comments
Avinger, Inc. Kittycat 2 5 0.014 150 0.065 Peripheral OTW CTO crossing catheter; catheter shaft is preshaped for better steerability in the most tortuous anatomy; Juicebox compatible
Avinger, Inc. Ocelot 6 0.014 110 0.079 Peripheral OTW CTO crossing catheter with onboard real-time OCT intravascular imaging for precise catheter navigation
Avinger, Inc. Ocelot Pixl 5 0.014 135 0.067 Peripheral OTW CTO crossing catheter with onboard real-time OCT intravascular imaging for precise catheter navigation
Avinger, Inc. Wildcat 6 0.035 110 0.079 Peripheral OTW CTO crossing catheter with three different modes of operation to cross any lesion; Juicebox compatible
Bard Peripheral Vascular, Inc. Crosser 5 0.014 (no wire for S6 Catheter) 106, 146 (Crosser S6: 106, 154) High-frequency mechanical vibration, hydrophilic coating; available as OTW, no-wire, and rapid-exchange; needs Crosser Generator System and FlowMate Injector
Bard Peripheral Vascular, Inc. Microsheath XL 7 0.014 130 0.067 Support catheter; for use with peripheral Crosser CTO recanalization catheter
Bard Peripheral Vascular, Inc. Usher 7 0.014 70, 110 Support catheter; for use with peripheral Crosser CTO recanalization catheter
Boston Scientific Corporation OffRoad Re-Entry Catheter System 5 (1.75 mm) 6 F (2 mm) 70, 100 5 F (1.75 mm) Designed for true lumen reentry from subintimal space of the artery; the 5.4-mm articulating positioning balloon directs the system, creating a path for the Micro-Catheter Lancet to reenter the vessel with precision and ease
Boston Scientific Corporation TruePath CTO Device 0.017 (0.43 mm) 0.018 (0.46 mm) compatible catheter 165 0.018 (0.46 mm) Intraluminal treatment of CTOs: 0.018-inch (0.46-mm) guidewire with diamond-coated, rotating distal tip; shaping tool allows for 15° angle; extension capability to 335 cm; compatible with any 0.018-inch (0.46-mm) compatible catheters ≤ 135 cm
Control Medical Technology Spinr 0.014–0.035 Up to 200 High-performance guidewire and catheter controller to torque, spin, and oscillate during diagnostic and interventional procedures
Cordis, a Cardinal Health company Frontrunner XP 6 90, 140 0.039 Atraumatic actuating distal blunt tip is designed to minimize risk of vessel perforation
Cordis, a Cardinal Health company Outback Elite 6 0.014 80, 120 Enables reentry of a guidewire from the subintimal space back into the true lumen via reentry cannula and highly visible L and T markers
Cordis, a Cardinal Health company Outback LTD 6 0.014 120 Enables reentry of a guidewire from the subintimal space back into the true lumen via reentry cannula and highly visible L and T markers
EndoCross Enabler-P Catheter System 5 0.035 107 0.070 Peripheral OTW balloon catheter system enabling true luminal crossing of peripheral CTOs; the Enabler-P catheter system provides increased tip force, distal pushability, and controlled advancement of a standard guidewire
Medtronic Enteer Re-entry System, Catheter 5 0.018 135, 150 0.066 Reentry catheter designed with a unique flat balloon to self-orient in the subintimal space and easily target the true lumen using the Enteer Guidewire; catheter available in two sizes for above- and BTK use
Medtronic Enteer Re-entry System, Guidewire 0.014 300 Specialized guidewire designed to target Enteer catheter exit ports and engage and penetrate tissue for re-entry into the true lumen from a subintimal position; available in three levels of stiffness (flexible, standard, stiff) for use across a range of peripheral vessels
Medtronic Viance Crossing Catheter 5 0.014 150 0.066 Low-profile peripheral CTO crossing catheter with atraumatic distal tip; device operates via physician-controlled torque handle for fast manual spinning; the spinning motion created by the torque device allows the catheter tip to find its way through the lesion; available in flexible and standard stiffness
Philips Pioneer Plus Intravascular Ultrasound Guided Re-entry Catheter 6 0.014 120 0.087 Peripheral re-entry catheter that utilizes IVUS guidance to precisely target re-entry into the true lumen
Reflow Medical, Inc Wingman14 Crossing Catheter 2.7 0.014 65, 135, 150 0.035
Reflow Medical, Inc Wingman18 Crossing Catheter 3.8 0.018 90, 135, 150 0.050
Reflow Medical, Inc Wingman35 Crossing Catheter 4.6 0.035 65, 90, 135 0.060
Spectranetics Corporation Quick-Access Needle Holder 23 Up to 0.035 Simplifies distal punctures for retrograde punctures, increases control and precision, and provides quick loading of guidewire into the vessel
Spectranetics Corporation Quick-Cross 1.8 distal tip (0.018-inch wire) 90, 135, 150 0.044 Low-profile, hydrophilic-coated, tapered-tip catheter provides seamless catheter-to-guidewire transition to facilitate crossing of challenging lesions and tracking through tortuous anatomy
Spectranetics Corporation Quick-Cross 1.5 distal tip (0.014-inch wire) 135, 150 0.039 Low-profile, hydrophilic-coated, tapered-tip catheter provides seamless catheter-to-guidewire transition to facilitate crossing of challenging lesions and tracking through tortuous anatomy
Spectranetics Corporation Quick-Cross 3.1 distal tip (0.035-inch wire) 65, 90, 135, 150 0.063 Low-profile, hydrophilic-coated, tapered-tip catheter provides seamless catheter-to-guidewire transition to facilitate crossing of challenging lesions and tracking through tortuous anatomy
Spectranetics Corporation Quick-Cross Capture 110 Up to 0.035 The funnel makes guidewire retrieval and exchange easy, reliable, and safe especially during complex retrograde procedures
Spectranetics Corporation Quick-Cross Extreme 3.2 distal tip (0.035-tip wire) 65, 90, 135, 150 0.059 Low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, and pushability to track through complex anatomy
Spectranetics Corporation Quick-Cross Extreme 2.1 distal tip (0.018-inch wire) 90, 135, 150 0.044 Low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, and pushability to track through complex anatomy
Spectranetics Corporation Quick-Cross Extreme 1.9 distal tip (0.014-inch wire) 135, 150 0.042 Low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, and pushability to track through complex anatomy
Spectranetics Corporation Quick-Cross Select 3.2 distal tip (0.035-inch wire) 65, 90, 135, 150 0.059 Angled and low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, pushability, and allows the ability to navigate through complex anatomy
Spectranetics Corporation Quick-Cross Select 2.1 distal tip (0.018-inch wire) 90, 135, 150 0.044 Angled and low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, pushability, and allows the ability to navigate through complex anatomy
Spectranetics Corporation Quick-Cross Select 1.9 distal tip (0.014-inch wire) 135, 150 0.042 Angled and low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, pushability, and allows the ability to navigate through complex anatomy

Contact Info

For advertising rates and opportunities, contact:
Craig McChesney
484-581-1816
cmcchesney@bmctoday.com

Stephen Hoerst
484-581-1817
shoerst@bmctoday.com

Charles Philip
484-581-1873
cphillip@bmctoday.com

About Endovascular Today

Endovascular Today is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field. Our Editorial Advisory Board is composed of the top endovascular specialists, including interventional cardiologists, interventional radiologists, vascular surgeons, neurologists, and vascular medicine practitioners, and our publication is read by an audience of more than 22,000 members of the endovascular community.