Utility of the FLEX Dynamic Scoring Catheter® in Peripheral Interventions

Dynamic scoring technology to improve outcomes in lower extremity intervention.

By Thomas Zeller, MD; Mehdi H. Shishehbor, DO, MPH, PhD; Frank R. Arko III, MD; and John Pigott, MD
 

The prevalence of peripheral artery disease (PAD) is increasing and is estimated to affect more than 200 million people worldwide.1,2 The safety and efficacy of peripheral interventions compared to surgical revascularization have been established.3

Standard practice for the treatment of PAD is balloon angioplasty, at times accompanied by adjunctive therapies to provide the optimal acute result for the patient. However, balloon angioplasty alone may result in flow-limiting dissection and increase the need for bailout stenting.4 Additionally, there is concern for restenosis requiring repeat interventions. Dynamic scoring can be used to prepare a vessel and create an optimal environment for balloon angioplasty, decreasing the occurrence of dissections and the need for stenting.

CASE REPORT: CHRONIC TOTAL OCCLUSION IN THE SFA

A 72-year-old woman with Rutherford class 3 symptoms presented with a 410-mm chronic total occlusion (CTO) in the left superficial femoral artery (SFA). The lesion was accessed via a contralateral approach, and the vessel was prepped with the FLEX Dynamic Scoring Catheter® device (VentureMed Group, Inc.). Four retrograde pullbacks with the device were utilized with a 30° rotation between passes. Angiographic evaluation after treatment with FLEX alone noted recanalization of the SFA (Figure 1). The lesion was then treated with a 5- X 150-mm drug-coated balloon (DCB), with an opening pressure of 4 atm. The final angiogram revealed a widely patent SFA without recoil or dissection.

Figure 1. Initial angiogram. Arrows indicate a CTO in the SFA (A). Post-FLEX recanalization (B). Final angiographic result (C).

Courtesy of Dr. Oriowo, Promedica/Jobst Vascular Institute, OH.

Figure 2. The FLEX Dynamic Scoring Catheter deployed with the scoring basket fully expanded (A). The FLEX scoring basket flexing to the contour of the vessel walls at the site of a high-grade stenosis (B).

FLEX DYNAMIC SCORING CATHETER DEVICE

The FLEX Dynamic Scoring Catheter device was purposely engineered to enable vessel preparation prior to angioplasty. The FLEX is composed of a novel, sheathed, three-strut scoring basket that “flexes” to follow the contours of the diseased vessel wall, creating controlled depth microincisions. Laser-welded to each of the three scoring elements is a surgical atherotome, 0.010 inches in height, mounted perpendicular on a protective skid. The skids allow for the device to follow the vessel walls during retrograde pullback, controlling the depth of the atherotome incisions. Visualization of the device under x-ray is excellent, as the scoring basket is constructed from stainless steel (Figure 2). The FLEX can also be rotationally controlled to create multiple linear scores around the vessel circumference with repeated passes in a single insertion. A braided shaft provides a high degree of torqueability. The handle contains two actuators—one to retract the sheath and the other to expand the scoring basket (Figure 3). The FLEX Scoring Catheter is 6-F compatible, can be used with a 0.014- or 0.018-inch guidewire, and is available in two working lengths: 40 and 120 cm. The device has a 2-mm crossing profile. CE Mark approval was received in November 2015 and US Food and Drug Administration clearance was granted in June 2016. The FLEX is indicated for use to facilitate dilations of stenoses in the femoral and popliteal arteries.

Figure 3. FLEX Dynamic Scoring Catheter schematic.

Mechanism of Action

Scoring balloons and angioplasty balloons use static or focused force to treat the lesions, requiring high pressures to engage the scoring elements.5 Additionally, balloon-based devices require multiple inflations to treat long lesions, increasing the risk of dissections.6 The FLEX Dynamic Scoring Catheter has a bimodal mechanism of action. First, the FLEX scoring elements exert approximately 1 atm of constant pressure against the vessel wall to gently predilate the stenosis or CTO. Second, the active movement of the blade across the vessel surface (Dynamic Scoring Technology®) allows the atherotome to incise the plaque at pressures much lower than balloon-based devices using static or focused force.

The FLEX Dynamic Scoring Catheter device creates parallel microincisions at a precisely controlled depth during retrograde pullback. Prepping the vessel with the FLEX device also allows the angioplasty balloon to fully efface stenoses or CTOs at significantly lower pressures as compared to vessels undergoing standard plain old balloon angioplasty (POBA). Human cadaveric SFA reveals consistent depth of microincisions in both histologic specimens as well as optical coherence tomographic (OCT) imaging (Figure 4).

Figure 4. OCT image. Yellow arrows indicate microincisions, the red arrow indicates a calcium cleft, and blue arrows identify area of elastic lamina (A). Histology of microincision created by the FLEX Catheter in a human cadaver SFA (B).

Postmarket Clinical Results

Postmarket surveillance data have been collected from 352 real-world cases by 88 physicians in 57 health systems since December 2015 (Table 1). The average lesion length treated was 134.3 mm (range, 2–410 mm), with 218 (61.9%) cases longer than 80 mm. The average initial stenosis was 91.2% (range, 50%–100%); CTOs accounted for 160 (45.5%) cases. Moderate to severe calcification was recorded in 54% (191) of the cases. The FLEX Catheter alone prior to balloon angioplasty created an average luminal gain of 27.4%. There have been no flow-limiting dissections, perforations, or embolizations reported with use of the FLEX Dynamic Scoring Catheter.

Operators opted to use DCB in 258 (73.3%) cases, validating the FLEX Catheter as a vessel prep device prior to DCB. The opening pressure, defined as the lowest pressure required to achieve full lesion effacement, averaged 4.4 atm, which is significantly below nominal pressure. Improved vessel compliance is suggested in the low balloon opening pressures and is likely responsible for the low percentage of observed dissections. There have been no flow-limiting dissections, and 17 minor dissections (14 type A and three type B dissections per the National Heart, Lung, and Blood Institute classification system)7 reported post-FLEX and angioplasty. No adverse events have been reported to date, and the resulting residual stenosis after FLEX and any adjunctive treatment averaged 9.8% (range, 0%–60%).

Additional data from the FLEX Dynamic Scoring Catheter in real-world patients support that the device is effective in facilitating treatment in lesions with differing degrees of stenosis, lesion lengths, and severity of calcification.8-11

Vessel Preparation

Other devices are being investigated for use in vessel preparation, including atherectomy devices. Atherectomy devices currently lack a method of depth control to minimize the impact to deeper vessel wall layers. There is a growing body of evidence that disruption of the elastic lamina and the accompanying inflammatory response of the vessel leads to restenosis.12,13 Directional atherectomy was studied in 116 patients, and histologic analysis identified adventitial injury in 53% of the patients. Comparison of 1-year outcomes for patients without and with adventitial injury reported a significantly higher rate of restenosis in the latter group.14 Additionally, atherectomy devices are costly and can require a multitude of sizes. The FLEX device provides a cost-effective vessel prep alternative and is a one-size-fits-most platform, decreasing inventory carrying cost (budget and shelf space) and requiring only one SKU.

CASE REPORT: SFA PREPPED WITH THE FLEX DYNAMIC SCORING CATHETER

A 68-year-old woman with Rutherford class 3 symptoms (ankle-brachial index, 0.6) presented with a hemodynamically significant 30-mm-long stenosis at the origin of the left SFA. The lesion was accessed via a contralateral approach, and an initial angiogram confirmed a high-grade stenosis (Figure 5). The lesion was prepped with the FLEX Dynamic Scoring Catheter device with three passes rotated 30°. There was significant luminal gain noted post-FLEX treatment. A 6- X 40-mm DCB was subsequently used to treat the lesion at an opening pressure of 3 atm (maximum inflation pressure, 6 atm), resulting in a widely patent artery and restoration of pedal pulses.

Figure 5. Preprocedure angiogram of a left femoral bifurcation stenosis (A). Post- FLEX recanalization (B). Postprocedure angiogram (C).

Courtesy of Dr. Ice, Deborah Heart and Lung, NJ.

CONCLUSION

The FLEX Dynamic Scoring Catheter is a vessel preparation device for endovascular intervention. Clinical data support that the device is safe and effective in creating luminal gain, increasing vessel compliance, and improving the overall results of balloon angioplasty. Physicians often use the FLEX device prior to a DCB, recognizing it as a vessel prep device. Vessel preparation with the FLEX Catheter creates an improved acute result, lowering the rates of dissection, and subsequently lessening the need for stents. This improvement may impact the long-term results of POBA and DCB use and will need to be further investigated.

1. Tadwalkar RM, Lee MS. The current state of endovascular intervention for peripheral arterial disease. Vascular Disease Management. 2015;12:E190-E203.

2. Criqui MH, Aboyans V. Epidemiology of peripheral artery disease. Circ Res. 2015;116:1509-1526.

3. Adam DJ, Beard JD, Cleveland T, et al. Bypass versus angioplasty in severe ischaemia of the leg (BASIL): multicentre, randomised controlled trial. Lancet. 2005;366:1925-1934.

4. Shammas NW, Coiner D, Shammas G, Jerin M. Predictors of provisional stenting in patients undergoing lower extremity arterial interventions. Int J Angiol. 2011;20:95-100.

5. Canaud LM, Alric PM, PhD, Berthet JM, et al. Infrainguinal cutting balloon angioplasty in de novo arterial lesions. J Vasc Surg. 2008;48:1182-1188.

6. Tan M, Urasawa K, Koshida R, et al. Comparison of angiographic dissection patterns caused by long vs short balloons during balloon angioplasty of chronic femoropopliteal occlusions. J Endovasc Ther. 2018;25:192-200.

7. Huber MS, Mooney JF, Madison J, Mooney MR. Use of a morphologic classification to predict clinical outcome after dissection from coronary angioplasty. Am J Cardiol. 1991;68:467-471.

8. Abstracts from the International Symposium on Endovascular Therapy (ISET) 2018. J Vasc Interv Radiol. 2018;29:e1-e26.

9. Pigott JP. Real world results of a dynamic scoring device in calcified femoropopliteal vessels. Presented at Charing Cross International Symposium; April 24–27, 2018; London, United Kingdom.

10. Yoho J, Lopez L, Pigott JP. A comparative review of the FLEX Catheter in the treatment of femoropopliteal lesions of differing lengths. Presented at New Cardiovascular Horizons; May 30–June 1, 2018; New Orleans, LA.

11. Zeller T, Lopez L, Pigott JP. Early clinical results utilizing the FLEX Catheter in 100 femoropopliteal chronic total occlusions. Presented at the International Symposium on Endovascular Therapy (ISET); February 2–7, 2018; Hollywood, FL.

12. Krishnan P, Martinsen BJ, Tarricone A, et al. Minimal medial injury after orbital atherectomy. J Endovasc Ther. 2017;24:167-168.

13. Kuku KO, Garcia-Garcia HM, Koifman E, et al. Intravascular ultrasound assessment of the effect of laser energy on the arterial wall during the treatment of femoro-popliteal lesions: a CliRpath excimer laser system to enlarge lumen openings (CELLO) registry study. Int J Cardiovasc Imaging. 2018;34:345-352.

14. Tarricone A, Ali Z, Rajamanickam A, et al. Histopathological evidence of adventitial or medial injury is a strong predictor of restenosis during directional atherectomy for peripheral artery disease. J Endovasc Ther. 2015;22:712-715.

Thomas Zeller, MD
Department of Angiology
Universitäts-Herzzentrum
Freiburg-Bad Krozingen
Bad Krozingen, Germany
Disclosures: None.

Mehdi H. Shishehbor, DO, MPH, PhD
Professor of Medicine
Case Western Reserve University
Cardiovascular Interventional Center
Harrington Heart & Vascular Institute
Cleveland, Ohio
Disclosures: None.

Frank R. Arko III, MD
Chief, Vascular and Endovascular Surgery
Professor, Cardiovascular Surgery
Co-Director, Aortic Institute
Sanger Heart and Vascular Institute
Carolinas Health Care System
Charlotte, North Carolina
Disclosures: None.

John Pigott, MD
Founder and Chief Science Officer
VentureMed Group
Jobst Vascular Institute
Promedica Health System
Toledo, Ohio

 

Contact Info

For advertising rates and opportunities, contact:
Craig McChesney
484-581-1816
cmcchesney@bmctoday.com

Stephen Hoerst
484-581-1817
shoerst@bmctoday.com

Charles Philip
484-581-1873
cphillip@bmctoday.com

About Endovascular Today

Endovascular Today is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field. Our Editorial Advisory Board is composed of the top endovascular specialists, including interventional cardiologists, interventional radiologists, vascular surgeons, neurologists, and vascular medicine practitioners, and our publication is read by an audience of more than 22,000 members of the endovascular community.