Group 7 Copy 3 Created with Sketch.
News Issue Archive Device Guide Calendar Subscribe Advertising

MENU

Centers

Carotid Dialysis EVAR Embolization HTN Limb Salvage Neurointervention Oncology PE Radial Regulatory Renal SFA TEVAR Venous

News Current Issue Archive Device Guide Calendar Subscribe Advertising About Contact Privacy Submissions
Carotid Dialysis EVAR Embolization HTN Limb Salvage Neurointervention Oncology PE Radial Regulatory Renal SFA TEVAR Venous

Back to Top

Advertisement

Advertisement

DIAGNOSTIC-WIRES-1 Company Directory


WallabyPhenox

,

down-arrow Created with Sketch.
down-arrow Created with Sketch.

Balloons / PTA Balloons

View Chart
Company Name Product Name Nominal Pressure (atm) Rated Burst Pressure (atm) Guidewire Compatibility (inch) Shaft Length (cm) Sheath Compatibility (F) Balloon Diameters (mm) Balloon Lengths (cm)
WallabyPhenox pITA Rapid Exchange Neurovascular PTA Balloon Catheter 6, 10 14, 18 0.016 160 > 4.2 1.25, 1.5, 2, 2.25, 2.5, 2.75, 3, 3.5, 4 1, 1.5, 2, 2.5, 3, 3.5, 4

Advertisement

Advertisement

Embolization / Embolization Coils

View Chart
Company Name Product Name Type (Detachable, Pushable) Material Coil Diameter (mm) Coil Length (cm) Recommended Delivery Catheter Sizes (ID) (inch) CE Mark Indications
WallabyPhenox Avenir Embolic Coil System Detachable Platinum (1-25) 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 18, 20, 22, 25 (1-60) 1, 2, 3, 4, 5, 6, 8, 10, 11, 13, 15, 16, 17, 19, 20, 23, 24, 27, 30, 34, 37, 40, 43, 47, 50, 60 0.017 Intended for endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistula; also intended for arterial and venous embolization in the peripheral vasculature

Wires / Hydrophilic Guidewires

View Chart
Company Name Product Name Type Diameter (inch) Length (cm) Tip Type
WallabyPhenox pORTAL Steerable Hydrophilic Guidewire Steerable hydrophilic guidewire 0.014 205 Straight, shapeable

Other Devices / Aneurysm Neck Bridging Devices (Continued)

View Chart
Company Name Product Name Shaft Diameter (mm) Shaft Length (mm) Crown Diameter (mm) Minimum Microcatheter (inch) Parent Vessel Diameter (mm)
WallabyPhenox pCANVAS Bifurcation Aneurysm Flow Modulating Implant 4 20, 25 5, 6, 8, 10 0.027 2.5 (minimum), 3.5 (maximum)
WallabyPhenox pCONUS 2 Bifurcation Aneurysm Implant 4 15 5, 6, 7, 8, 10, 12, 15 0.021 2.5 (minimum), 3.7 (maximum)
WallabyPhenox pCONUS Bifurcation Aneurysm Implant 3, 4 20, 25 4, 5, 6, 8, 10, 12, 15 0.021 2.2 (minimum), 3.9 (maximum)

Other Devices / Mechanical Thrombectomy (Neurovascular)

View Chart
Company Name Product Name Sheath Compatibility (F) Guidewire Compatibility (inch) Working Length (cm) Mode of Operation CE Mark Indications
WallabyPhenox Preset Lite Thrombectomy Device 0.0165 inch (ID) – 180 (insertion wire) Introduced into the target vessel through a suitable microcatheter and deployed inside the thrombus or distal to the thrombus; after complete deployment the slow withdrawal of the instrument occurs under continuous aspiration via the guiding catheter or aspiration catheter Designed for mechanical clot retrieval from intracranial arteries as acute ischemic stroke treatment for patients who are ineligible for intravenous thrombolysis or for patients who failed thrombolysis therapy and as a supplement treatment of an initiated thrombolysis therapy
WallabyPhenox Preset Thrombectomy Device 0.021 inch (ID) – 180 (insertion wire) Introduced into the target vessel through a suitable microcatheter and deployed inside the thrombus or distal to the thrombus; after complete deployment the slow withdrawal of the instrument occurs under continuous aspiration via the guiding catheter or aspiration catheter Designed for mechanical clot retrieval from intracranial arteries as acute ischemic stroke treatment for patients who are ineligible for intravenous thrombolysis or for patients who failed thrombolysis therapy and as a supplement treatment of an initiated thrombolysis therapy

More Categories:

Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View All

Advertisement

Latest News


September 22, 2026

Mölnlycke Launches Biogel Radiation Protection Gloves

September 18, 2026

Piraeus Medical Launches FDA-Cleared 6-F 70 NeuGlide Catheter

September 18, 2026

Radiation Protection Device Developer Texray Appoints Dr. Ziv Haskal to Advisory Board

Most Read Articles


Navigating the 2026 Lower Extremity CPT Code Restructure

By Jeffrey G. Carr, MD

Improving PAD Awareness, Access, and Amputation Prevention

With Eric A. Secemsky, MD, MSc, RPVI, FACC, FAHA, FSCAI, FSVM

SEISMIQ™ IVL System as a Next-Generation Technology Offering for Complex PAD

With Jaafer Golzar, MD, FACC, FSCAI, and Gregory A. Stanley, MD, FACS

Back to Top
Carotid Dialysis EVAR Embolization HTN Limb Salvage Neurointervention Oncology PE Radial Regulatory Renal SFA TEVAR Venous
Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Pulmonary Embolism Radial Regulatory Renal SFA TEVAR Venous

News• Current Issue• Archive• Device Guide• Advertising• About Calendar• Contact• Privacy• Submissions• Subscriptions


Endovascular Today (ISSN 1551-1944 print and ISSN 2689-792X online) is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field.



magazine Created with Sketch.

Free Print Subscriptions

Fill 1 Created with Sketch.

Email Newsletter



twitter-icon LinkedIn Created with Sketch. instagram BlueSky-Circle
Cardiac Interventions Today
Group 7 Copy 3 Created with Sketch.
bmc-secondary-mark-color copy Created with Sketch.

© 2026 Bryn Mawr Communications II, LLC.  
All Rights Reserved   •   Privacy Policy

one-trust-button