Catheters / Microcatheters
View Chart| Company Name | Product Name | Type of Catheter Construction | Proximal Size (F) | Middle Size (F) | Distal Size (F) | Catheter Working Length (cm) | Catheter Endhole Diameter ID (inch) | Recommended Guidewire Size (inch) | Radiopaque Tip (Yes/No) | Hydrophilic Coating (Yes/No) |
|---|---|---|---|---|---|---|---|---|---|---|
| Acandis GmbH & Co. KG | NeuroSlider 17 | Stainless steel braiding with inner PTFE liner | 2.1 | – | 1.9 | 155 | 0.0165 | 0.014 (maximum) | Yes, two markers | Yes |
| Acandis GmbH & Co. KG | NeuroSlider 21 | Stainless steel braiding with inner PTFE liner | 2.5 | – | 2.4 | 155 | 0.021 | 0.018 (maximum) | Yes, two markers | Yes |
| Acandis GmbH & Co. KG | NeuroSlider 27 | Stainless steel braiding with inner PTFE liner | 3.6 | – | 3 | 155 | 0.027 | 0.021 (maximum) | Yes, one marker | Yes |
Advertisement
Advertisement
Stents / Cerebral Stents
View Chart| Company Name | Product Name | Materials Used | Stent Diameters (mm) | Stent Lengths (mm) | Recommended Guidewire Size (inch) | Recommended Guide Catheter Size (inch) |
|---|---|---|---|---|---|---|
| Acandis GmbH & Co. KG | Acclino Stent System | Nitinol; laser-cut, closed-cell design | 3.5, 4.5 | 15, 25, 35 | 0.010–0.014 | 1.9-F microcatheter (ID: 0.0165) included |
Other Devices / Mechanical Thrombectomy (Neurovascular)
View Chart| Company Name | Product Name | Sheath Compatibility (F) | Guidewire Compatibility (inch) | Working Length (cm) | Mode of Operation | CE Mark Indications |
|---|---|---|---|---|---|---|
| Acandis GmbH & Co. KG | Aperio 1.9 F Thrombectomy Device | – | 0.010–0.014 | 30 mm | Thrombectomy device for the mechanical extraction of clots from cerebral vessels with a diameter > 2 and ≤ 4 mm | Intended for use of restoration of the arterial flow for patients diagnosed with ischemic stroke due to large intracranial vessel occlusion (ie, internal carotid artery, M1 and M2 segments of the MCA); patients who fail intravenous thrombolytic therapy or who are ineligible for thrombolysis may be suited for treatment with the Aperio device |
| Acandis GmbH & Co. KG | Aperio 3 F Thrombectomy System | – | 0.010–0.014 | 40 mm | Thrombectomy system (includes microcatheter) for the mechanical extraction of clots from cerebral vessels with a diameter > 2 and ≤ 4 mm | Intended for use of restoration of the arterial flow for patients diagnosed with ischemic stroke due to large intracranial vessel occlusion (ie, internal carotid artery, M1 and M2 segments of the MCA); patients who fail intravenous thrombolytic therapy or who are ineligible for thrombolysis may be suited for treatment with the Aperio device |