Group 7 Copy 3 Created with Sketch.
News Issue Archive Device Guide Calendar Subscribe Advertising

MENU

Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

News Current Issue Archive Device Guide Calendar Subscribe Advertising About Contact Privacy Submissions
Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

Back to Top

Advertisement

Advertisement

EURO Company Directory


phenox GmbH

Lise-Meitner-Allee 31, 44801 Bochum, Germany

PHONE: +49 (0) 234-36 919-0

down-arrow Created with Sketch.
down-arrow Created with Sketch.

Balloons / PTA Balloons

View Chart
Company Name Product Name Nominal Pressure (atm) Rated Burst Pressure (atm) Guidewire Compatibility (inch) Shaft Length (cm) Sheath Compatibility (F) Balloon Diameters (mm) Balloon Lengths (cm)
phenox GmbH pITA Rapid Exchange Neurovascular PTA Balloon Catheter 6, 10 14, 18 0.016 160 > 4.2 1.25, 1.5, 2, 2.25, 2.5, 2.75, 3, 3.5, 4 1, 1.5, 2, 2.5, 3, 3.5, 4

Advertisement

Advertisement

Wires / Hydrophilic Guidewires

View Chart
Company Name Product Name Type Diameter (inch) Length (cm) Tip Type
phenox GmbH pORTAL Steerable Hydrophilic Guidewire Steerable hydrophilic guidewire 0.014 205 Straight, shapeable

Other Devices / Aneurysm Neck Bridging Devices (Continued)

View Chart
Company Name Product Name Shaft Diameter (mm) Shaft Length (mm) Crown Diameter (mm) Minimum Microcatheter (inch) Parent Vessel Diameter (mm)
phenox GmbH pCANVAS Bifurcation Aneurysm Flow Modulating Implant 4 20, 25 5, 6, 8, 10 0.027 2.5 (minimum), 3.5 (maximum)
phenox GmbH pCONUS 2 Bifurcation Aneurysm Implant 4 15 5, 6, 7, 8, 10, 12, 15 0.021 2.5 (minimum), 3.7 (maximum)
phenox GmbH pCONUS Bifurcation Aneurysm Implant 3, 4 20, 25 4, 5, 6, 8, 10, 12, 15 0.021 2.2 (minimum), 3.9 (maximum)

Other Devices / Mechanical Thrombectomy (Neurovascular)

View Chart
Company Name Product Name Sheath Compatibility (F) Guidewire Compatibility (inch) Working Length (cm) Mode of Operation CE Mark Indications
phenox GmbH Preset Lite Thrombectomy Device 0.0165 inch (ID) – 180 (insertion wire) Introduced into the target vessel through a suitable microcatheter and deployed inside the thrombus or distal to the thrombus; after complete deployment the slow withdrawal of the instrument occurs under continuous aspiration via the guiding catheter or aspiration catheter Designed for mechanical clot retrieval from intracranial arteries as acute ischemic stroke treatment for patients who are ineligible for intravenous thrombolysis or for patients who failed thrombolysis therapy and as a supplement treatment of an initiated thrombolysis therapy
phenox GmbH Preset Thrombectomy Device 0.021 inch (ID) – 180 (insertion wire) Introduced into the target vessel through a suitable microcatheter and deployed inside the thrombus or distal to the thrombus; after complete deployment the slow withdrawal of the instrument occurs under continuous aspiration via the guiding catheter or aspiration catheter Designed for mechanical clot retrieval from intracranial arteries as acute ischemic stroke treatment for patients who are ineligible for intravenous thrombolysis or for patients who failed thrombolysis therapy and as a supplement treatment of an initiated thrombolysis therapy

More Categories:

Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View All

Advertisement

Latest News


April 17, 2026

Bayer’s Asundexian FXIa Inhibitor Demonstrates Reduction in Ischemic Stroke in OCEANIC-STROKE Study

April 16, 2026

Rapid Medical’s Tigertriever 25 Cleared by FDA to Treat LVO Stroke

April 15, 2026

Stereotaxis to Acquire Robocath

Most Read Articles


A Private Practice Physician’s Experience Treating Chronic Venous Insufficiency

By Robert A. Edwards, DO

Update on Modern Complex Abdominal Aortic Repair Options

With Jason T. Lee, MD; Steven Maximus, MD, FACS; Gustavo Oderich, MD, FACS; Benjamin W. Starnes, MD, FACS; Carlos Timaran, MD; Kak Khee Yeung, MD, PhD, FEBVS; and Javairiah Fatima, MD, FACS, DFSVS

Transforming the Future of PE Care: Expanding Mechanical Thrombectomy Through Innovation

By Mehdi Shishehbor, DO, MPH, PhD

Back to Top
Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous
Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

News• Current Issue• Archive• Device Guide• Advertising• About Calendar• Contact• Privacy• Submissions• Subscriptions


Endovascular Today (ISSN 1551-1944 print and ISSN 2689-792X online) is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field.



magazine Created with Sketch.

Free Print Subscriptions

Fill 1 Created with Sketch.

Email Newsletter



twitter-icon LinkedIn Created with Sketch. instagram BlueSky-Circle
Cardiac Interventions Today
Group 7 Copy 3 Created with Sketch.
bmc-secondary-mark-color copy Created with Sketch.

© 2026 Bryn Mawr Communications II, LLC.  
All Rights Reserved   •   Privacy Policy

one-trust-button