Advertisement
Advertisement
Rapid Medical
P.O.B. 337, Carmel building, Yokneam 2069205 Israel
PHONE: 972-72-250-3331
Wires / Hydrophilic Guidewires
View Chart| Company Name | Product Name | Type | Diameter (inch) | Length (cm) | Tip Type |
|---|---|---|---|---|---|
| Rapid Medical | Drivewire 24 Guidewire | Stainless steel with an inner nitinol braided flexible coil and hydrophilic coating on the distal segment of the wire | 0.024 | 202 | Steerable |
Advertisement
Advertisement
Other Devices / Mechanical Thrombectomy (Neurovascular)
View Chart| Company Name | Product Name | Sheath Compatibility (F) | Guidewire Compatibility (inch) | Working Length (cm) | Mode of Operation | CE Mark Indications |
|---|---|---|---|---|---|---|
| Rapid Medical | Tigertriever XL | 0.021 inch (ID) | – | 220 | Incorporates a manually expandable braided distal segment designed to conform to vessel anatomy and thrombus morphology, enabling atraumatic engagement; controlled expansion via the handle allows precise thrombus capture while relieving vascular tension prior to retrieval, promoting safe and effective clot removal | Designed for use in flow restoration of patients with ischemic stroke due to large intracranial vessel occlusion; patients who are ineligible for intravenous tissue plasminogen activator (IV t-PA) or who fail IV t-PA therapy are candidates for treatment |
| Rapid Medical | Tigertriever 13 | 0.0165/0.013 inch (ID) | – | 230 | Adjusts to the vasculature and clot providing an atraumatic approach; precise control to capture the thrombus and remove the tension from the vasculature before removal leading to safe and effective procedure; the user can control the manual expansion of the braided distal portion into the clot using the handle component of the device | Designed for use in flow restoration of patients with ischemic stroke due to large intracranial vessel occlusion; patients who are ineligible for intravenous tissue plasminogen activator (IV t-PA) or who fail IV t-PA therapy are candidates for treatment; designed for use in flow restoration of patients with ischemic stroke due to distal vessel occlusions with a diameter of 1-2 mm |
| Rapid Medical | Tigertriever 17 | 0.017 inch (ID) | – | 220 | Adjusts to the vasculature and clot providing an atraumatic approach; unique operation changes these procedures from a passive to an active user approach that accelerates clot capture and potentially reduces the risk of vascular injury during removal; the user can control the manual expansion of the braided distal portion into the clot using the handle component of the device | Designed for use in flow restoration of patients with ischemic stroke due to large intracranial vessel occlusion; patients who are ineligible for intravenous tissue plasminogen activator (IV t-PA) or who fail IV t-PA therapy are candidates for treatment |
| Rapid Medical | Tigertriever 25 | 0.025 inch (ID) | – | 220 | Incorporates a manually expandable braided distal segment designed to conform to vessel anatomy and thrombus morphology, enabling atraumatic engagement; controlled expansion via the handle allows precise thrombus capture while relieving vascular tension prior to retrieval, promoting safe and effective clot removal | Designed for use in flow restoration of patients with ischemic stroke due to large intracranial vessel occlusion; patients who are ineligible for intravenous tissue plasminogen activator (IV t-PA) or who fail IV t-PA therapy are candidates for treatment |
| Rapid Medical | Tigertriever | 0.021 inch (ID) | – | 220 | Incorporates a manually expandable braided distal segment designed to conform to vessel anatomy and thrombus morphology, enabling atraumatic engagement; controlled expansion via the handle allows precise thrombus capture while relieving vascular tension prior to retrieval, promoting safe and effective clot removal | Designed for use in flow restoration of patients with ischemic stroke due to large intracranial vessel occlusion; patients who are ineligible for intravenous tissue plasminogen activator (IV t-PA) or who fail IV t-PA therapy are candidates for treatment |
Other Devices / Assist Devices
View Chart| Company Name | Product Name | Assisting/Supporting Part Diameter (mm) | Assisting/Supporting Part Length (mm) | Distal Tip Length (mm) | Minimum Microcatheter ID Compatibility (inch) | Total Length (cm) |
|---|---|---|---|---|---|---|
| Rapid Medical | Comaneci | 2.3 | 32 | 7 | 0.021 | 224 |
| Rapid Medical | Comaneci Petit | 1.9 | 24 | 7 | 0.021 | 223 |
| Rapid Medical | Comaneci 17 | 1.85 | 223 cm | 7 | 0.017 | 223 |
More Categories:
Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View AllAdvertisement