Group 7 Copy 3 Created with Sketch.
News Issue Archive Device Guide Calendar Subscribe Advertising

MENU

Centers

Carotid Dialysis EVAR Embolization HTN Limb Salvage Neurointervention Oncology PE Radial Regulatory Renal SFA TEVAR Venous

News Current Issue Archive Device Guide Calendar Subscribe Advertising About Contact Privacy Submissions
Carotid Dialysis EVAR Embolization HTN Limb Salvage Neurointervention Oncology PE Radial Regulatory Renal SFA TEVAR Venous

Back to Top

Advertisement

Advertisement

EUROPE Company Directory


Penumbra, Inc. (Peripheral Vascular)

1351 Harbor Bay Parkway, Alameda, CA 94502

PHONE: (510) 748-3200 | FAX: (510) 748-3232

down-arrow Created with Sketch.
down-arrow Created with Sketch.

Catheters / Microcatheters

View Chart
Company Name Product Name Type of Catheter Construction Proximal Size (F) Middle Size (F) Distal Size (F) Catheter Working Length (cm) Catheter Endhole Diameter ID (inch) Recommended Guidewire Size (inch) Radiopaque Tip (Yes/No) Hydrophilic Coating (Yes/No)
Penumbra, Inc. (Peripheral Vascular) Lantern Delivery Microcatheter Nitinol coil reinforced; eight extrusion zones; three tip shapes: straight, 45°, and 90° 2.95 – 2.6 115, 135, 150 0.025 ≤ 0.023 Yes; two markerbands, radiopaque 3 cm Yes

Advertisement

Advertisement

Embolization / Embolization Coils

View Chart
Company Name Product Name Type (Detachable, Pushable) Material Coil Diameter (mm) Coil Length (cm) Recommended Delivery Catheter Sizes (ID) (inch) CE Mark Indications
Penumbra, Inc. (Peripheral Vascular) Packing Coil Detachable Platinum Shapeless 5, 15, 30, 45, 60 0.025–0.027 high-flow microcatheters (Lantern) Indicated for arterial and venous embolizations in the peripheral vasculature
Penumbra, Inc. (Peripheral Vascular) POD Detachable with dedicated anchor segment for high flow vessel sacrifice Platinum 3–14 mm 20–60 0.025–0.027 high-flow microcatheters (Lantern) Indicated for arterial and venous embolizations in the peripheral vasculature
Penumbra, Inc. (Peripheral Vascular) Ruby Coil Detachable Platinum 2–40 mm (3D complex shape, multiple softness levels) 1–60 0.025–0.027 high-flow microcatheters (Lantern) Indicated for arterial and venous vessel embolizations in the peripheral vasculature
Penumbra, Inc. (Peripheral Vascular) Packing Coil LP Detachable Platinum Wave shape conforms to vessel diameter 3, 6, 10, 15, 30, 45, 60 0.0165–0.021 (low-profile microcatheter) LP Coil is indicated for arterial and venous embolizations in the peripheral vasculature
Penumbra, Inc. (Peripheral Vascular) Ruby Coil LP Detachable Platinum 1–10 (3D complex shape) 1–70 0.0165–0.021 (low-profile microcatheter) LP Coil is indicated for arterial and venous embolizations in the peripheral vasculature

Sheaths / Special Access Sheaths

View Chart
Company Name Product Name Size (F) Length (cm) Guidewire Compatibility (inch) Curved or Straight Radiopaque Tip Type of Special Access
Penumbra, Inc. (Peripheral Vascular) Element Vascular Access System 17 13, 33, 45, 65, 80 0.038 Straight Yes Laser-cut hypotube sheath designed for VTE

Sheaths / Standard Sheaths

View Chart
Company Name Product Name Size (F) Length (cm) Guidewire Compatibility (inch) Curved or Straight Radiopaque Tip
Penumbra, Inc. (Peripheral Vascular) Element Vascular Access System 17 12, 33, 45, 65, 80 0.038 Straight Yes

Other Devices / Mechanical Thrombectomy/Thrombolysis (Peripheral/Venous)

View Chart
Company Name Product Name Sheath Compatibility (F) Guidewire Compatibility (inch) Working Length (cm) Mode of Operation CE Mark Indications
Penumbra, Inc. (Peripheral Vascular) Indigo System Catheters: CAT8, CAT7D, CAT6, CAT RX 8 (CAT8), 7 (CAT7D), 6 (CAT6), 6-F guide catheter (CAT RX) 0.014–0.038 50–160 The Indigo System Catheters are paired with Penumbra ENGINE for continuous, powerful aspiration As part of the Indigo Aspiration System, the Indigo aspiration catheters and separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems; as part of the Indigo Aspiration System, the Indigo CAT RX Aspiration Catheters and Indigo Separator 4 are indicated for the removal of fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature
Penumbra, Inc. (Peripheral Vascular) Indigo System Separator: SEP12, SEP7, SEP7D, SEP8, SEP6, SEP5, and SEPC4 – – 90–200 The device is advanced and retracted through the Indigo catheter at the proximal margin of the primary occlusion to facilitate clearing of the thrombus from the catheter tip, as needed As part of the Indigo Aspiration System, the Indigo aspiration catheters and separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems, and for the treatment of pulmonary embolism
Penumbra, Inc. (Peripheral Vascular) Indigo System Catheters: Lightning Flash 2.0 16 0.014-0.038 80-115 Lightning Flash Aspiration Tubing facilitates the transfer of vacuum between INDIGO Flash Aspiration Catheter and Penumbra Aspiration Pump while providing intermittent or continuous aspiration The Indigo Aspiration Catheters and Separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems and for the treatment of pulmonary embolism; as part of the INDIGO Aspiration System, the INDIGO Sterile Aspiration Tubing is indicated to connect the INDIGO Aspiration Catheters to the Penumbra Aspiration Pump
Penumbra, Inc. (Peripheral Vascular) Indigo System Catheters: Lightning Bolt 7, Bolt 6X, Bolt 12 6 (Lightning Bolt 6X), 7 (Lightning Bolt 7), 12 (Lightning Bolt 12) 0.014–0.038 100–132 Lightning Bolt Aspiration Tubing is designed to serve as a conduit to assist in thrombus removal, facilitating transfer of vacuum between the Penumbra Aspiration Pump and the INDIGO Aspiration Catheter while providing intermittent, continuous, or modulated aspiration; modulated aspiration is provided when the Lightning Bolt Aspiration Tubing alternates between connecting the INDIGO Aspiration Catheter to the Penumbra Aspiration Pump and a sterile saline intravenous (IV) bag at ambient pressure The Indigo Aspiration Catheters and Separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems and for the treatment of pulmonary embolism; as part of the INDIGO Aspiration System, the INDIGO Sterile Aspiration Tubing is indicated to connect the INDIGO Aspiration Catheters to the Penumbra Aspiration Pump
Penumbra, Inc. (Peripheral Vascular) Indigo System Catheters: Lightning 7 and 12 7 (Lightning 7), 12 (Lightning 12) 0.014–0.038 100–130 The Indigo System with Lightning Aspiration Tubing is computer aided mechanical aspiration powered by the Penumbra ENGINE which utilizes a unique mechanism of action to help optimize thrombus removal procedures by differentiating between thrombus and blood; Lightning comes packaged as Lightning 7 and Lightning 12 As part of the INDIGO Aspiration System, the INDIGO Aspiration Catheters and Separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems, and for the treatment of pulmonary embolism

Other Devices / Occlusion Devices

View Chart
Company Name Product Name Type Position CE Mark Indications
Penumbra, Inc. (Peripheral Vascular) Packing Coil LP Detachable Low-profile microcatheter deliverable LP Coil is indicated for arterial and venous embolizations in the peripheral vasculature
Penumbra, Inc. (Peripheral Vascular) Ruby Coil Detachable High-flow microcatheter deliverable Indicated for arterial and venous vessel embolizations in the peripheral vasculature
Penumbra, Inc. (Peripheral Vascular) POD Detachable with dedicated anchor segment for high flow vessel sacrifice High-flow microcatheter deliverable Indicated for arterial and venous embolizations in the peripheral vasculature
Penumbra, Inc. (Peripheral Vascular) Packing Coil Detachable High-flow microcatheter deliverable Indicated for arterial and venous embolizations in the peripheral vasculature

More Categories:

Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View All

Advertisement

Latest News


October 13, 2026

InterVene’s Recana Thrombectomy System Studied for Venous ISR and RVO

October 13, 2026

Early Data Presented From Real-World Registry of Medtronic’s Abre Venous Stent System

October 13, 2026

Thrombolex Device for Mechanically Channeled Thrombolysis Evaluated in RAPID-PE

Most Read Articles


Improving PAD Awareness, Access, and Amputation Prevention

With Eric A. Secemsky, MD, MSc, RPVI, FACC, FAHA, FSCAI, FSVM

Expanding Neurovascular Applications of the Swift™ Coil System

With Mohsen Nouri, MD; Robert M. Starke, MD; Allison E. Strickland, MD; and Nitin Goyal, MD

SEISMIQ™ IVL System as a Next-Generation Technology Offering for Complex PAD

With Jaafer Golzar, MD, FACC, FSCAI, and Gregory A. Stanley, MD, FACS

Back to Top
Carotid Dialysis EVAR Embolization HTN Limb Salvage Neurointervention Oncology PE Radial Regulatory Renal SFA TEVAR Venous
Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Pulmonary Embolism Radial Regulatory Renal SFA TEVAR Venous

News• Current Issue• Archive• Device Guide• Advertising• About Calendar• Contact• Privacy• Submissions• Subscriptions


Endovascular Today (ISSN 1551-1944 print and ISSN 2689-792X online) is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field.



magazine Created with Sketch.

Free Print Subscriptions

Fill 1 Created with Sketch.

Email Newsletter



twitter-icon LinkedIn Created with Sketch. instagram BlueSky-Circle
Cardiac Interventions Today
Group 7 Copy 3 Created with Sketch.
bmc-secondary-mark-color copy Created with Sketch.

© 2026 Bryn Mawr Communications II, LLC.  
All Rights Reserved   •   Privacy Policy

one-trust-button