Advertisement
Advertisement
Penumbra, Inc. (Peripheral Vascular)
1351 Harbor Bay Parkway, Alameda, CA 94502
PHONE: (510) 748-3200 | FAX: (510) 748-3232
Catheters / Microcatheters
View Chart| Company Name | Product Name | Type of Catheter Construction | Proximal Size (F) | Middle Size (F) | Distal Size (F) | Catheter Working Length (cm) | Catheter Endhole Diameter ID (inch) | Recommended Guidewire Size (inch) | Radiopaque Tip (Yes/No) | Hydrophilic Coating (Yes/No) |
|---|---|---|---|---|---|---|---|---|---|---|
| Penumbra, Inc. (Peripheral Vascular) | Lantern Delivery Microcatheter | Nitinol coil reinforced; eight extrusion zones; three tip shapes: straight, 45°, and 90° | 2.95 | – | 2.6 | 115, 135, 150 | 0.025 | ≤ 0.023 | Yes; two markerbands, radiopaque 3 cm | Yes |
Advertisement
Advertisement
Embolization / Embolization Coils
View Chart| Company Name | Product Name | Type (Detachable, Pushable) | Material | Coil Diameter (mm) | Coil Length (cm) | Recommended Delivery Catheter Sizes (ID) (inch) | CE Mark Indications |
|---|---|---|---|---|---|---|---|
| Penumbra, Inc. (Peripheral Vascular) | Packing Coil | Detachable | Platinum | Shapeless | 5, 15, 30, 45, 60 | 0.025–0.027 high-flow microcatheters (Lantern) | Indicated for arterial and venous embolizations in the peripheral vasculature |
| Penumbra, Inc. (Peripheral Vascular) | POD | Detachable with dedicated anchor segment for high flow vessel sacrifice | Platinum | 3–14 mm | 20–60 | 0.025–0.027 high-flow microcatheters (Lantern) | Indicated for arterial and venous embolizations in the peripheral vasculature |
| Penumbra, Inc. (Peripheral Vascular) | Ruby Coil | Detachable | Platinum | 2–40 mm (3D complex shape, multiple softness levels) | 1–60 | 0.025–0.027 high-flow microcatheters (Lantern) | Indicated for arterial and venous vessel embolizations in the peripheral vasculature |
| Penumbra, Inc. (Peripheral Vascular) | Packing Coil LP | Detachable | Platinum | Wave shape conforms to vessel diameter | 3, 6, 10, 15, 30, 45, 60 | 0.0165–0.021 (low-profile microcatheter) | LP Coil is indicated for arterial and venous embolizations in the peripheral vasculature |
| Penumbra, Inc. (Peripheral Vascular) | Ruby Coil LP | Detachable | Platinum | 1–10 (3D complex shape) | 1–70 | 0.0165–0.021 (low-profile microcatheter) | LP Coil is indicated for arterial and venous embolizations in the peripheral vasculature |
Sheaths / Special Access Sheaths
View Chart| Company Name | Product Name | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Curved or Straight | Radiopaque Tip | Type of Special Access |
|---|---|---|---|---|---|---|---|
| Penumbra, Inc. (Peripheral Vascular) | Element Vascular Access System | 17 | 13, 33, 45, 65, 80 | 0.038 | Straight | Yes | Laser-cut hypotube sheath designed for VTE |
Sheaths / Standard Sheaths
View Chart| Company Name | Product Name | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Curved or Straight | Radiopaque Tip |
|---|---|---|---|---|---|---|
| Penumbra, Inc. (Peripheral Vascular) | Element Vascular Access System | 17 | 12, 33, 45, 65, 80 | 0.038 | Straight | Yes |
Other Devices / Mechanical Thrombectomy/Thrombolysis (Peripheral/Venous)
View Chart| Company Name | Product Name | Sheath Compatibility (F) | Guidewire Compatibility (inch) | Working Length (cm) | Mode of Operation | CE Mark Indications |
|---|---|---|---|---|---|---|
| Penumbra, Inc. (Peripheral Vascular) | Indigo System Catheters: CAT8, CAT7D, CAT6, CAT RX | 8 (CAT8), 7 (CAT7D), 6 (CAT6), 6-F guide catheter (CAT RX) | 0.014–0.038 | 50–160 | The Indigo System Catheters are paired with Penumbra ENGINE for continuous, powerful aspiration | As part of the Indigo Aspiration System, the Indigo aspiration catheters and separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems; as part of the Indigo Aspiration System, the Indigo CAT RX Aspiration Catheters and Indigo Separator 4 are indicated for the removal of fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature |
| Penumbra, Inc. (Peripheral Vascular) | Indigo System Separator: SEP12, SEP7, SEP7D, SEP8, SEP6, SEP5, and SEPC4 | – | – | 90–200 | The device is advanced and retracted through the Indigo catheter at the proximal margin of the primary occlusion to facilitate clearing of the thrombus from the catheter tip, as needed | As part of the Indigo Aspiration System, the Indigo aspiration catheters and separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems, and for the treatment of pulmonary embolism |
| Penumbra, Inc. (Peripheral Vascular) | Indigo System Catheters: Lightning Flash 2.0 | 16 | 0.014-0.038 | 80-115 | Lightning Flash Aspiration Tubing facilitates the transfer of vacuum between INDIGO Flash Aspiration Catheter and Penumbra Aspiration Pump while providing intermittent or continuous aspiration | The Indigo Aspiration Catheters and Separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems and for the treatment of pulmonary embolism; as part of the INDIGO Aspiration System, the INDIGO Sterile Aspiration Tubing is indicated to connect the INDIGO Aspiration Catheters to the Penumbra Aspiration Pump |
| Penumbra, Inc. (Peripheral Vascular) | Indigo System Catheters: Lightning Bolt 7, Bolt 6X, Bolt 12 | 6 (Lightning Bolt 6X), 7 (Lightning Bolt 7), 12 (Lightning Bolt 12) | 0.014–0.038 | 100–132 | Lightning Bolt Aspiration Tubing is designed to serve as a conduit to assist in thrombus removal, facilitating transfer of vacuum between the Penumbra Aspiration Pump and the INDIGO Aspiration Catheter while providing intermittent, continuous, or modulated aspiration; modulated aspiration is provided when the Lightning Bolt Aspiration Tubing alternates between connecting the INDIGO Aspiration Catheter to the Penumbra Aspiration Pump and a sterile saline intravenous (IV) bag at ambient pressure | The Indigo Aspiration Catheters and Separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems and for the treatment of pulmonary embolism; as part of the INDIGO Aspiration System, the INDIGO Sterile Aspiration Tubing is indicated to connect the INDIGO Aspiration Catheters to the Penumbra Aspiration Pump |
| Penumbra, Inc. (Peripheral Vascular) | Indigo System Catheters: Lightning 7 and 12 | 7 (Lightning 7), 12 (Lightning 12) | 0.014–0.038 | 100–130 | The Indigo System with Lightning Aspiration Tubing is computer aided mechanical aspiration powered by the Penumbra ENGINE which utilizes a unique mechanism of action to help optimize thrombus removal procedures by differentiating between thrombus and blood; Lightning comes packaged as Lightning 7 and Lightning 12 | As part of the INDIGO Aspiration System, the INDIGO Aspiration Catheters and Separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems, and for the treatment of pulmonary embolism |
Other Devices / Occlusion Devices
View Chart| Company Name | Product Name | Type | Position | CE Mark Indications |
|---|---|---|---|---|
| Penumbra, Inc. (Peripheral Vascular) | Packing Coil LP | Detachable | Low-profile microcatheter deliverable | LP Coil is indicated for arterial and venous embolizations in the peripheral vasculature |
| Penumbra, Inc. (Peripheral Vascular) | Ruby Coil | Detachable | High-flow microcatheter deliverable | Indicated for arterial and venous vessel embolizations in the peripheral vasculature |
| Penumbra, Inc. (Peripheral Vascular) | POD | Detachable with dedicated anchor segment for high flow vessel sacrifice | High-flow microcatheter deliverable | Indicated for arterial and venous embolizations in the peripheral vasculature |
| Penumbra, Inc. (Peripheral Vascular) | Packing Coil | Detachable | High-flow microcatheter deliverable | Indicated for arterial and venous embolizations in the peripheral vasculature |
More Categories:
Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View AllAdvertisement