Sponsored by Cook Medical

An Overview of Superficial Femoral Artery Stenting

The history, data, and latest advancements in stenting of the SFA and popliteal arteries.

By John R. Laird, MD, and Ehrin J. Armstrong, MD
 

During the past decade, multiple technologies have been developed for treatment of superficial femoral artery (SFA) atherosclerotic disease, including balloon angioplasty, bare nitinol self-expanding stents, drug-eluting nitinol stents, and drug-coated balloons. Although many endovascular treatment options exist, nitinol stents remain a mainstay of SFA therapy.1 This article reviews the historical development of SFA stent technologies, with an emphasis on recent advances and data supporting the use of stents in the SFA and popliteal arteries.

SUPERIORITY OF SFA STENTS OVER BALLOON ANGIOPLASTY

The Vienna Absolute study was the first randomized study to show superiority of primary stenting over balloon angioplasty for the treatment of moderate-length SFA lesions.2 In that study, patients were randomized 1:1 to a Dynalink* or Absolute* stent (Abbott Vascular) versus balloon angioplasty. At 1 year, primary patency was significantly higher for patients treated with a stent (63% vs 37%). However, other randomized studies conducted with the Luminexx stent (Bard Peripheral Vascular) failed to show a benefit of stent placement for shorter-length (mean, 40 mm) SFA lesions.3 At the same time, concerns regarding a high prevalence of stent fracture in the SFA using early generation self-expanding stents limited the broad application of stents to the femoropopliteal segment.4

The RESILIENT trial was the second major randomized trial to show superiority of primary stent placement over balloon angioplasty for the treatment of moderate-length SFA lesions.5 Patients were randomized 2:1 to placement of a LifeStent (Bard Peripheral Vascular) versus balloon angioplasty. At 12 months, the primary patency rate was significantly higher for patients randomized to primary stent placement based on both intention-to-treat analysis (81% vs 36%) and as-treated analysis (80% vs 61%). The stent fracture rate was only 3% at 1 year. At 3-year follow-up, patients randomized to primary stent placement also had significantly higher freedom from target lesion revascularization (TLR) in the intention-to-treat group (75.5% vs 41.8%).6 These results provided significant evidence in support of primary stenting to treat moderate-length SFA lesions with modern stent designs.

REGISTRY STUDIES OF SFA STENTS

After completion of early, randomized studies of nitinol self-expanding stents versus balloon angioplasty, the majority of subsequent studies have consisted of registry data supporting the incremental improvement of new-generation stents. These studies have, in general, been based on the VIVA objective performance goals in the SFA and have shown excellent rates of primary patency, as well as extremely low stent fracture rates when compared to earlier stent designs.7 In most cases, reports of these registries have led to US Food and Drug Administration approval of an SFA-specific indication for these stents (Table 1).

Two of the more recent registries highlight improvements in outcomes with newer-generation self-expanding stents. The SUMMIT study was a prospective, multicenter registry of the Epic* stent (Boston Scientific Corporation), which is a laser-cut nitinol self-expanding stent that contains radiopaque tantalum markers at the proximal and distal ends.8 At 1-year of follow-up, the binary restenosis rate was 15.7%, with a freedom from TLR rate of 92%. Among patients with available x-rays, there were no stent fractures at follow-up.

The COMPLETE SE multicenter trial studied use of the Complete SE stent (Medtronic, Inc.), which has an offset crown design that may minimize crown interaction during flexion.9 At 1 year, the primary patency rate was 72.6%, with a clinically driven TLR rate of only 8.4%. No fractures were observed, although determination was difficult in some cases due to deployment in heavily calcified lesions.

Based on these recent registry studies, current-generation nitinol self-expanding stents have improved rates of primary patency, with low to zero rates of stent fractures and improved patient-reported outcomes.

RECENT DEVELOPMENTS IN SFA STENTS

SFA stent technologies continue to undergo significant improvement with a goal toward increased durability and conformability in the SFA and popliteal arteries with better long-term patency. The Supera stent (Abbott Vascular) is a recently approved stent with a novel woven design that results in improved flexibility, increased radial strength, and resistance to fracture. The SUPERB study reported a primary patency rate of 86% in the pivotal registry data submitted for US Food and Drug Administration approval.10

Other stent designs under investigation include the Tigris* stent (Gore & Associates), which has a nitinol wire frame with ePTFE coating and interconnecting ePTFE linking regions; the SMART Flex* stent (Flexible Stenting Solutions, acquired by Cordis Corporation), which has helical strut bands and flex bridges that provide flexibility while maintaining longitudinal integrity; and the BioMimics 3D* stent (Veryan Medical), which has a helical design that may promote laminar flow. This new generation of flexible stents may provide increased conformability and continue to improve outcomes of femoropopliteal stenting.

DRUG-ELUTING STENTS IN THE SFA

Initial studies of drug-eluting stents (DES) in the SFA were hampered by lack of clinical benefit compared to non-DES. These early DES included both sirolimus-eluting and everolimus-eluting designs using an earlier-generation stent platform.11,12 Subsequently, a paclitaxel-eluting stent has shown significant benefit in the SFA in comparison to both balloon angioplasty and placement of a bare-nitinol self-expanding stent. The Zilver PTX (Cook Medical) is a nitinol scaffold stent with a polymer-free coating that elutes paclitaxel. In the ZILVER PTX study, patients were randomized to placement of a paclitaxel-eluting Zilver stent versus balloon angioplasty; a second arm of the study randomized patients to Zilver PTX versus bare-metal stenting in cases of acute failure of balloon angioplasty.13 At 1 year, the primary patency rate was 83% in the DES group and 32% for the PTA group. In the secondary randomization, 12-month primary patency with Zilver PTX was superior to Zilver BMS (89.9% vs 73%). These results support the superiority of the Zilver PTX stent over balloon angioplasty and an additional benefit of drug elution compared to Zilver without the drug coating.

Based on these results, DES provide significant promise for improving patency and long-term outcomes among patients with femoropopliteal occlusive disease. Further refinement of drug-eluting technology and application to new stent scaffolds and balloon technologies will significantly improve the outcomes of endovascular interventions in the SFA.

John R. Laird, MD, is Professor of Medicine and Medical Director of the Vascular Center, University of California Davis Medical Center in Sacramento, California. He has disclosed that he is a consultant/advisory board member for Abbott Vascular, Bard Peripheral Vascular, Boston Scientific, Covidien, and Medtronic, and receives research support from W.L. Gore. Additionally, he is paid by Cook Medical for speaking. Dr. Laird may be reached at (916) 734-2028; john.laird@ucdmc.ucdavis.edu.

Ehrin J. Armstrong, MD, is Associate Professor of Medicine at the Division of Cardiology, University of Colorado School of Medicine in Aurora, Colorado. He has disclosed that he is a consultant/advisory board member for Spectranetics, Abbott Vascular, and Pfizer. Dr. Armstrong may be reached at ehrin.armstrong@gmail.com.

Neither Dr. Laird nor Dr. Armstrong were paid for writing this article.

*These devices are investigational or not indicated for use in the SFA in the United States.

  1. Aghel A, Armstrong EJ. Recent advances in self-expanding stents for use in the superficial femoral and popliteal arteries. Exp Rev Cardiovasc Ther, 2014;12:833-842.
  2. Schillinger M, Sabeti S, Loewe C, et al. Balloon angioplasty versus implantation of nitinol stents in the superficial femoral artery. New Engl J Med. 2006;354:1879-1888.
  3. Krankenberg H, Schluter M, Steinkamp HJ, et al. Nitinol stent implantation versus percutaneous transluminal angioplasty in superficial femoral artery lesions up to 10 cm in length: the Femoral Artery Stenting Trial (FAST). Circulation. 2007;116:285-292.
  4. Schlager O, Dick P, Sabeti S, et al. Long segmental SFA stenting – the dark sides: in-stent restenosis, clinical deterioration, and stent fractures. J Endovasc Ther. 2005;12:676-684.
  5. Laird JR, Katzen BT, Scheinert D, et al. Nitinol stent implantation versus balloon angioplasty for lesions in the superficial femoral artery and proximal popliteal artery: twelve-month results from the RESILIENT randomized trial. Circ: Cardiovasc Interv. 2010;3:267-276.
  6. Laird JR, Katzen BT, Scheinert D, et al. Nitinol stent implantation vs balloon angioplasty for lesions in the superficial femoral and proximal popliteal arteries of patients with claudication: three-year follow-up from the RESILIENT randomized trial. J Endovasc Ther. 2012;19;1-9.
  7. Rocha-Singh K, Jaff MR, Crabtree TR, et al. Performance goals and endpoint assessments for clinical trials of femoropopliteal bare nitinol stents in patients with symptomatic peripheral arterial disease. Cathet Cardiovasc Interv. 2007;69;910-919.
  8. Werner M, Piorkowski M, Thieme M, et al. SUMMIT registry: one-year outcomes after implantation of the EPIC self-expanding nitinol stent in the femoropopliteal segment. J Endovasc Ther. 2013;20:759-766.
  9. Laird JR, Jain A, Zeller T, et al. Nitinol stent implantation in the superficial femoral artery and proximal popliteal artery: twelve-month results from the Complete SE multicenter trial. J Endovasc Therapy. 2014;21:202-212.
  10. Supera Periperal Stent System. Available at http://www.abbottvascular.com/static/cms_workspace/pdf/ifu/ peripheral_intervention/eIFU_Supera.pdf. Accessed September 23, 2014.
  11. Duda SH, Bosiers M, Lammer J, et al. Drug-eluting and bare nitinol stents for the treatment of atherosclerotic lesions in the superficial femoral artery: long-term results from the SIROCCO trial. J Endovasc Therapy. 2006;13;701- 710.
  12. Lammer J, Bosiers M, Zeller T, et al. First clinical trial of nitinol self-expanding everolimus-eluting stent implantation for peripheral arterial occlusive disease. J Vasc Surg. 2011;54:394-401.
  13. Dake MD, Ansel GM, Jaff MR, et al. Paclitaxel-eluting stents show superiority to balloon angioplasty and bare metal stents in femoropopliteal disease: twelve-month Zilver PTX randomized study results. Circ: Cardiovasc Interv. 2011;4:495-504.
 

Contact Info

For advertising rates and opportunities, contact:
Craig McChesney
484-581-1816
cmcchesney@bmctoday.com

Stephen Hoerst
484-581-1817
shoerst@bmctoday.com

Charles Philip
484-581-1873
cphillip@bmctoday.com

About Endovascular Today

Endovascular Today is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field. Our Editorial Advisory Board is composed of the top endovascular specialists, including interventional cardiologists, interventional radiologists, vascular surgeons, neurologists, and vascular medicine practitioners, and our publication is read by an audience of more than 22,000 members of the endovascular community.