Indicated for the treatment of patients diagnosed with renal artery stenosis and/or aortoiliac occlusive disease, including lesions at the aortic bifurcation, when endovascular therapy is required; for the treatment of patients with aneurysmal disease, when fenestrated endovascular aortic repair (FEVAR) or branched endovascular aortic repair (BEVAR) is required; for the treatment of patients with iliac artery aneurysmal disease, requiring treatment with an iliac branch device (IBD); use in renal arteries is limited to 5 mm, 6 mm, and 7 mm diameter sizes; use in EVAR and IBD is limited to 5-10 mm diameter sizes
Getinge
Advanta V12 Balloon-Expandable Covered Stent
316 L stainless steel, PTFE encapsulated
0.035
9
12
29, 41, 61
80, 120
Restoring and improving the patency of the iliac arteries
Bentley InnoMed GmbH
BeFlared FEVAR
CoCr (L-605), ePTFE covering folded inside and clamped on both ends
0.035
6, 7
5/8, 6/8, 7/10, 8/10, 9/11
22–37
120
Indicated for use as a bridging stent graft in patients requiring endovascular abdominal aortic aneurysm repair with a fenestrated aortic endovascular graft to keep the visceral arteries perfused
Bentley InnoMed GmbH
BeFlow iliac
CoCr (L-605)m ePTFE covering folded inside and clamped on both ends
0.035
6, 7
7, 8, 9, 10
37, 57
75
Indicated for permanent intraluminal placement in iliac arteries for restoring and improving the patency impaired by arteriosclerosis or other stenoses that may be treated by stenting
Bentley InnoMed GmbH
BeGraft
Cobalt chromium (L605), ePTFE
0.035
6 (diameter: 5–8 mm), 7 (diameter: 9–10 mm)
5, 6, 7, 8, 9, 10
18, ~23, ~28, ~38, ~58
75, 120
Indicated for permanent intraluminal placement in iliac and renal arteries for restoring and improving the patency impaired by arteriosclerosis or other stenoses that may be treated by stenting; sealing aneurysms, acute perforations, acute ruptures and fistulas; as a bridging stent graft in patients requiring endovascular abdominal aortic aneurysm repair with a fenestrated aortic endovascular graft to keep the visceral arteries perfused; sizes approved when used for permanent intraluminal placement in iliac and renal arteries: Ø 5 mm and 6 mm in lengths of 18 mm, 22 mm, 28 mm, 38 mm, and 58 mm; Ø 7 mm in lengths of 18 mm, 23 mm, 27 mm, 37 mm, and 57 mm; Ø 8 mm - 10 mm in lengths of 27 mm, 37 mm, and 57 mm; sizes approved when used as a bridging stent graft for FEVAR: Ø 5 mm and 6 mm in lengths of 22 mm, 28 mm, and 38 mm; Ø 7 mm in lengths of 23 mm, 27 mm, and 37 mm; Ø 8 mm -10 mm in lengths of 27 mm and 37 mm
Indicated for implantation in the native and/or recurrent coarctation of the aorta on adolescent or adult patients; restoring and improving the patency of the iliac arteries
Bentley InnoMed GmbH
BeGraft Coronary
Cobalt chromium (L605); ePTFE
0.014
5 (guide catheter)
2.5, 2.75, 3, 3.5, 4, 4.5, 5
8, 12, 16, 18, 21, 24
144, 154
Indicated for transluminal implantation in coronary arteries or aortocoronary bypass grafts for the treatment of (1) acute perforation or rupture of coronary arteries; and (2) aneurysm of coronary arteries or coronary bypass-vein graft
7/8 F for Ø 5 - 7 mm (depending on indication and access site), 8 F for Ø 8 mm, 8/9/10 F for Ø 9 and 10 mm (depending on indication and access site)
5, 6, 7, 8, 9, 10
~28, ~38, ~58, ~78
120
Indicated for permanent intraluminal placement in iliac and renal arteries for restoring and improving the patency impaired by arteriosclerosis or other stenoses that may be treated by stenting, sealing aneurysms, acute perforations, acute ruptures, and fistulas, as bridging stent graft in patients requiring endovascular abdominal aortic aneurysm repair with a branched aortic endovascular graft to keep the visceral arteries perfused; sizes approved when used for permanent intraluminal placement in iliac and renal arteries: Ø 5 mm and 6 mm in lengths of 28 mm, 38 mm, and 58 mm; Ø 7 mm - 10 mm in lengths of 27 mm, 37 mm, and 57 mm; sizes approved when used as a bridging stent graft for BEVAR: Ø 5 mm and 6 mm in lengths of 38 mm, 58 mm, and 78 mm; Ø 7 mm - 10 mm in lengths of 37 mm, 57 mm and 77 mm
Artivion, Inc.
E-ventus BX
Cobalt chromium ePTFE covered stent
0.035
6 (5–6-mm diameter), 7 (7–10-mm diameter)
5–10
18, 22, 23, 27, 28, 37, 38, 57, 58
120
Indicated for intraluminal chronic placement in iliac and renal arteries for restoring and improving vessel patency and treatment of aneurysms, acute perforations, acute ruptures, and fistulas
Gore & Associates
Gore Viabahn VBX Balloon-Expandable Endoprosthesis
Stainless steel stent/fluoropolymer graft
0.035
7, 8
5, 6, 7, 8, 8L, 9, 10, 11
15, 19, 29, 39, 59, 79
135
De novo or restenotic lesions in the iliac arteries, including lesions at the aortic bifurcation; de novo or restenotic lesions in the visceral arteries; isolated visceral, iliac, and subclavian artery aneurysms; or traumatic or iatrogenic vessel injuries in arteries that are located in the chest cavity, abdominal cavity, or pelvis (except for aorta, coronary, innominate, carotid, vertebral, and pulmonary arteries)
iVascular
iCover
CoCr L605 and ePTFE
0.035
6 (up to 8 mm diameter and 17 mm length), 7
5, 6, 7, 8, 9, 10
17, 27, 37, 57
80, 140
Indicated for restoring atherosclerotic lesions of the common and external iliac arteries and the renal arteries; treatment of aneurysms and perforations, ruptures and
acute fistulas