Group 7 Copy 3 Created with Sketch.
News Issue Archive Device Guide Calendar Subscribe Advertising

MENU

Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

News Current Issue Archive Device Guide Calendar Subscribe Advertising About Contact Privacy Submissions
Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

Back to Top

Advertisement

Advertisement

EURO Company Directory


Inari Medical

6001 Oak Canyon, Suite 100, Irvine, CA 92618

PHONE: (877) 923-4747

down-arrow Created with Sketch.
down-arrow Created with Sketch.

Other Devices / Mechanical Thrombectomy/Thrombolysis (Peripheral/Venous)

View Chart
Company Name Product Name Sheath Compatibility (F) Guidewire Compatibility (inch) Working Length (cm) Mode of Operation CE Mark Indications
Inari Medical ClotTriever Thrombectomy System 13, 16 0.035 80 Mechanical coring, collection, and retrieval of emboli and thrombi The nonsurgical removal of thrombi and emboli from blood vessels; injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel; intended for use in the peripheral vasculature including deep vein thrombosis
Inari Medical FlowTriever Catheter (disks) - FlowTriever Retrieval/Aspiration System 20, 22 0.035 115 Mechanical and aspirational disruption, fragmentation, maceration, and retrieval of emboli and thrombi The nonsurgical removal of emboli and thrombi from blood vessels, and injection, infusion and/or aspiration of contrast media and other fluids into or from a blood vessel; the FlowTriever System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism; Triever catheters are intended for use in treating clot in transit in the right atrium, but not in conjunction with FlowTriever catheters
Inari Medical FlowTriever2 Catheter (disks) - FlowTriever Retrieval/Aspiration System 20, 22, 24, 26 0.035 120 Mechanical and aspirational disruption, fragmentation, maceration, and retrieval of emboli and thrombi The nonsurgical removal of emboli and thrombi from blood vessels, and injection, infusion and/or aspiration of contrast media and other fluids into or from a blood vessel; FlowTriever2 is intended for use in the peripheral vasculature
Inari Medical Triever16 - FlowTriever Retrieval/Aspiration System 20, 22, 24 0.035 113 Mechanical and aspirational disruption, fragmentation, maceration, and retrieval of emboli and thrombi The nonsurgical removal of emboli and thrombi from blood vessels, and injection, infusion and/or aspiration of contrast media and other fluids into or from a blood vessel; the FlowTriever System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism; Triever catheters are intended for use in treating clot in transit in the right atrium, but not in conjunction with FlowTriever catheters
Inari Medical Triever20 - FlowTriever Retrieval/Aspiration System 20, 22, 24 0.035 90 Mechanical and aspirational disruption, fragmentation, maceration, and retrieval of emboli and thrombi The nonsurgical removal of emboli and thrombi from blood vessels, and injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel; the FlowTriever System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism; Triever catheters are intended for use in treating clot in transit in the right atrium but not in conjunction with FlowTriever catheters
Inari Medical Triever24 - FlowTriever Retrieval/Aspiration System 24, 26 0.035 90 Mechanical and aspirational disruption, fragmentation, maceration, and retrieval of emboli and thrombi The nonsurgical removal of emboli and thrombi from blood vessels, and injection, infusion and/or aspiration of contrast media and other fluids into or from a blood vessel; the FlowTriever System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism; Triever Catheters are intended for use in treating clot in transit in the right atrium, but not in conjunction with FlowTriever catheters

More Categories:

Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View All

Advertisement

Latest News


April 17, 2026

Bayer’s Asundexian FXIa Inhibitor Demonstrates Reduction in Ischemic Stroke in OCEANIC-STROKE Study

April 16, 2026

Rapid Medical’s Tigertriever 25 Cleared by FDA to Treat LVO Stroke

April 15, 2026

Stereotaxis to Acquire Robocath

Most Read Articles


A Private Practice Physician’s Experience Treating Chronic Venous Insufficiency

By Robert A. Edwards, DO

Update on Modern Complex Abdominal Aortic Repair Options

With Jason T. Lee, MD; Steven Maximus, MD, FACS; Gustavo Oderich, MD, FACS; Benjamin W. Starnes, MD, FACS; Carlos Timaran, MD; Kak Khee Yeung, MD, PhD, FEBVS; and Javairiah Fatima, MD, FACS, DFSVS

Transforming the Future of PE Care: Expanding Mechanical Thrombectomy Through Innovation

By Mehdi Shishehbor, DO, MPH, PhD

Back to Top
Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous
Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

News• Current Issue• Archive• Device Guide• Advertising• About Calendar• Contact• Privacy• Submissions• Subscriptions


Endovascular Today (ISSN 1551-1944 print and ISSN 2689-792X online) is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field.



magazine Created with Sketch.

Free Print Subscriptions

Fill 1 Created with Sketch.

Email Newsletter



twitter-icon LinkedIn Created with Sketch. instagram BlueSky-Circle
Cardiac Interventions Today
Group 7 Copy 3 Created with Sketch.
bmc-secondary-mark-color copy Created with Sketch.

© 2026 Bryn Mawr Communications II, LLC.  
All Rights Reserved   •   Privacy Policy

one-trust-button