A low-profile support catheter that has a crossing and targeted re-entry capability due to the steerable nitinol needle at the tip; a radiopaque marker indicates the direction in which the curved needle will protrude from the catheter’s tip; antegrade, retrograde, and crossover are possible for intraluminal and subintimal approach on 0.014- and 0.018-inch wire platform
EndoCross
Enabler-P Catheter System
5
0.035
107
0.070
Peripheral OTW balloon catheter system enabling true luminal crossing of peripheral CTOs; the Enabler-P catheter system provides increased tip force, distal pushability, and controlled advancement of a standard guidewire
Medtronic
Enteer Re-entry System, Catheter
5
0.018
135, 150
0.066
Re-entry catheter designed with a unique flat balloon to self-orient in the subintimal space and easily target the true lumen using the Enteer Guidewire; catheter available in two sizes for above- and below-the-knee use
Medtronic
Enteer Re-entry System, Guidewire
–
0.014
300
–
Specialized guidewire designed to target Enteer catheter exit ports and engage and penetrate tissue for re-entry into the true lumen from a subintimal position; available in three levels of stiffness (flexible, standard, stiff) for use across a range of peripheral vessels
Avinger, Inc.
Kittycat 2
5
0.014
150
0.065
Peripheral OTW CTO crossing catheter; catheter shaft is preshaped for better steerability in the most tortuous anatomy; Juicebox compatible
Avinger, Inc.
Ocelot
6
0.014
110
0.079
Peripheral OTW CTO crossing catheter with onboard real-time OCT intravascular imaging for precise catheter navigation
Avinger, Inc.
Ocelot Pixl
5
0.014
135
0.067
Peripheral OTW CTO crossing catheter with onboard real-time OCT intravascular imaging for precise catheter navigation
Cordis
Outback Elite Re-Entry Catheter
6
0.014
80, 120
–
Enables re-entry of a guidewire from the subintimal space back into the true lumen via re-entry cannula and highly visible L and T markers
Philips
Pioneer Plus IVUS-Guided Re-Entry Catheter
6
0.014
120
–
Peripheral re-entry catheter that utilizes IVUS guidance to precisely target re-entry into the true lumen
Philips
Quick-Cross Extreme Support Catheter
5
–
65, 90, 135, 150
–
Low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, and pushability to track through complex anatomy
Philips
Quick-Cross Extreme Support Catheter
4
–
135, 150
–
Low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, and pushability to track through complex anatomy
Philips
Quick-Cross Extreme Support Catheter
4
–
90, 135, 150
–
Low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, and pushability to track through complex anatomy
Philips
Quick-Cross Select Support Catheter
4
–
90, 135, 150
–
Angled and low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, pushability, and allows the ability to navigate through complex anatomy
Philips
Quick-Cross Select Support Catheter
4
–
135, 150
–
Angled and low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, pushability, and allows the ability to navigate through complex anatomy
Philips
Quick-Cross Select Support Catheter
5
–
65, 90, 135, 150
–
Angled and low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, pushability, and allows the ability to navigate through complex anatomy
Philips
Quick-Cross Support Catheter
5
–
65, 90, 135, 150
–
Low-profile, hydrophilic-coated, tapered-tip catheter provides seamless catheter-to-guidewire transition to facilitate crossing of challenging lesions and tracking through tortuous anatomy
Philips
Quick-Cross Support Catheter
4
–
90, 135, 150
–
Low-profile, hydrophilic-coated, tapered-tip catheter provides seamless catheter-to-guidewire transition to facilitate crossing of challenging lesions and tracking through tortuous anatomy
Philips
Quick-Cross Support Catheter
4
–
135, 150
–
Low-profile, hydrophilic-coated, tapered-tip catheter provides seamless catheter-to-guidewire transition to facilitate crossing of challenging lesions and tracking through tortuous anatomy
Merit Medical Systems, Inc.
Spinr High-Performance Guidewire Controller
–
0.014–0.038
–
0.014
Used to maneuver guidewires in the coronary and peripheral vasculature during interventional or diagnostic procedures; assists in accessing distal anatomy, navigating tortuous vessels, crossing old lesions, and working through fresh blockages
Coaxial peripheral crossing set; both inner catheter and outer sheath are hydrophilically coated; inner catheter is braided with radiopaque tip; outer sheath is coil reinforced to provide exceptional tracking through tortuous anatomy; a tungsten-loaded tip on the outer sheath aids pushability and radiopacity; outer sheath is tapered down to inner catheter to provide additional support, strength, and pushability across challenging lesions
Medtronic
Viance Crossing Catheter
5
0.014
150
0.066
Low-profile peripheral CTO crossing catheter with atraumatic distal tip; device operates via physician-controlled torque handle for fast manual spinning; the spinning motion created by the torque device allows the catheter tip to find its way through the lesion; available in flexible and standard stiffness
Avinger, Inc.
Wildcat
6
0.035
110
0.079
Peripheral OTW CTO crossing catheter with three different modes of operation to cross any lesion; Juicebox compatible
Reflow Medical, Inc
Wingman 14C CTO Crossing Catheter
2.7
0.014
90, 135, 150
0.039
A beveled (needle) tip recanalization device intended to provide additional support to a steerable guidewire when accessing discrete regions of the peripheral vasculature; the Wingman CTO Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable needle tip) and activating handle
Reflow Medical, Inc
Wingman14 CTO Crossing Catheter
2.7
0.014
65, 135, 150
0.039
A beveled (needle) tip recanalization device intended to provide additional support to a steerable guidewire when accessing discrete regions of the peripheral vasculature; the Wingman CTO Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable needle tip) and activating handle
Reflow Medical, Inc
Wingman18 CTO Crossing Catheter
3.8
0.018
90, 135, 150
0.052
A beveled (needle) tip recanalization device intended to provide additional support to a steerable guidewire when accessing discrete regions of the peripheral vasculature; the Wingman CTO Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable needle tip) and activating handle
Reflow Medical, Inc
Wingman35 CTO Crossing Catheter
4.6
0.035
65, 90, 135
0.066
A beveled (needle) tip recanalization device intended to provide additional support to a steerable guidewire when accessing discrete regions of the peripheral vasculature; the Wingman CTO Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable needle tip) and activating handle
Advertisement
Advertisement
We value keeping the Device Guide up to date.
If you want to add or update your company’s device listings, please let us know!