phenox GmbH
Lise-Meitner-Allee 31, 44801 Bochum, Germany
PHONE: +49 (0) 234-36 919-0
Balloons / PTA Balloons
View Chart| Company Name | Product Name | Nominal Pressure (atm) | Rated Burst Pressure (atm) | Guidewire Compatibility (inch) | Shaft Length (cm) | Sheath Compatibility (F) | Balloon Diameters (mm) | Balloon Lengths (cm) |
|---|---|---|---|---|---|---|---|---|
| phenox GmbH | pITA Rapid Exchange Neurovascular PTA Balloon Catheter | 6, 10 | 14, 18 | 0.016 | 160 | > 4.2 | 1.25, 1.5, 2, 2.25, 2.5, 2.75, 3, 3.5, 4 | 1, 1.5, 2, 2.5, 3, 3.5, 4 |
Advertisement
Advertisement
Wires / Hydrophilic Guidewires
View Chart| Company Name | Product Name | Type | Diameter (inch) | Length (cm) | Tip Type |
|---|---|---|---|---|---|
| phenox GmbH | pORTAL Steerable Hydrophilic Guidewire | Steerable hydrophilic guidewire | 0.014 | 205 | Straight, shapeable |
Other Devices / Aneurysm Neck Bridging Devices (Continued)
View Chart| Company Name | Product Name | Shaft Diameter (mm) | Shaft Length (mm) | Crown Diameter (mm) | Minimum Microcatheter (inch) | Parent Vessel Diameter (mm) |
|---|---|---|---|---|---|---|
| phenox GmbH | pCANVAS Bifurcation Aneurysm Flow Modulating Implant | 4 | 20, 25 | 5, 6, 8, 10 | 0.027 | 2.5 (minimum), 3.5 (maximum) |
| phenox GmbH | pCONUS 2 Bifurcation Aneurysm Implant | 4 | 15 | 5, 6, 7, 8, 10, 12, 15 | 0.021 | 2.5 (minimum), 3.7 (maximum) |
| phenox GmbH | pCONUS Bifurcation Aneurysm Implant | 3, 4 | 20, 25 | 4, 5, 6, 8, 10, 12, 15 | 0.021 | 2.2 (minimum), 3.9 (maximum) |
Other Devices / Mechanical Thrombectomy (Neurovascular)
View Chart| Company Name | Product Name | Sheath Compatibility (F) | Guidewire Compatibility (inch) | Working Length (cm) | Mode of Operation | CE Mark Indications |
|---|---|---|---|---|---|---|
| phenox GmbH | Preset Lite Thrombectomy Device | 0.0165 inch (ID) | – | 180 (insertion wire) | Introduced into the target vessel through a suitable microcatheter and deployed inside the thrombus or distal to the thrombus; after complete deployment the slow withdrawal of the instrument occurs under continuous aspiration via the guiding catheter or aspiration catheter | Designed for mechanical clot retrieval from intracranial arteries as acute ischemic stroke treatment for patients who are ineligible for intravenous thrombolysis or for patients who failed thrombolysis therapy and as a supplement treatment of an initiated thrombolysis therapy |
| phenox GmbH | Preset Thrombectomy Device | 0.021 inch (ID) | – | 180 (insertion wire) | Introduced into the target vessel through a suitable microcatheter and deployed inside the thrombus or distal to the thrombus; after complete deployment the slow withdrawal of the instrument occurs under continuous aspiration via the guiding catheter or aspiration catheter | Designed for mechanical clot retrieval from intracranial arteries as acute ischemic stroke treatment for patients who are ineligible for intravenous thrombolysis or for patients who failed thrombolysis therapy and as a supplement treatment of an initiated thrombolysis therapy |
More Categories:
Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View AllAdvertisement