Indicated for use in the treatment of superficial vein reflux of greater saphenous vein associated with varicosities, for treatment of incompetence and reflux of superficial veins in the lower extremity, and for the treatment of incompetent (ie, refluxing) perforator veins
iMS GmbH
AntiStick
Laser fiber 400 µm
1,940
4 (17 G)
260
Designed to direct laser energy at soft tissue during contact and noncontact surgical procedures, including in applications that involve the use of rigid and flexible endoscopes; they are suitable for use in vascular surgery
iMS GmbH
AntiStick
Laser fiber 600 µm
1,940
6
260
Designed to direct laser energy at soft tissue during contact and noncontact surgical procedures, including in applications that involve the use of rigid and flexible endoscopes; they are suitable for use in vascular surgery
iMS GmbH
AntiStick Pro
Laser fiber 600 µm
1,940
6
250
The intended use of the optical fiber probes is to deliver laser radiation from its source to the treatment site of the patient in the context of a medical laser surgery; the optical fiber probes are indicated in laser surgery application of different disciplines in minimally invasive surgery
iMS GmbH
AntiStick Pro
Laser fiber 400 µm
1,940
4 (16G)
250
The intended use of the optical fiber probes is to deliver laser radiation from its source to the treatment site of the patient in the context of a medical laser surgery; the optical fiber probes are indicated in laser surgery application of different disciplines in minimally invasive surgery
Merit Medical Systems, Inc.
ClariVein OC
Mechanochemical
–
4, 5
–
Indicated for infusion of physician-specified agents in the peripheral vasculature including for endovascular occlusion of incompetent veins in patients with superficial venous reflux
Medtronic
ClosureFast 3 cm Radiofrequency Ablation Catheter
Radiofrequency ablation
Heating length (3 cm); working length of 60 cm
7
7, 11
Intended for endovascular coagulation of blood vessels in patients with superficial venous reflux
Medtronic
ClosureFast 7 cm Radiofrequency Ablation Catheter
Radiofrequency ablation
Heating length (7 cm); working lengths of 60 and 100 cm
7
7, 11
Intended for endovascular coagulation of blood vessels in patients with superficial venous reflux
Medtronic
ClosureFast 8 cm Radiofrequency Ablation Catheter
Radiofrequency ablation
Heating length (8 cm); working lengths of 60 and 100 cm
6
7, 11
Intended for endovascular coagulation of blood vessels in patients with superficial venous reflux
Medtronic
ClosureRFG Radiofrequency Generator (Model 3)
Radiofrequency
–
–
–
Intended for use with the ClosureFast catheter (7, 3 cm) and ClosureRFS products
Medtronic
ClosureRFS Endovenous Radiofrequency Stylet
Radiofrequency
–
6 (with 12-cm working length)
–
Perforator veins
Biolas
Endosealer
Polymer-based agent
–
–
–
Treatment of varicose veins (superficial and tributary veins) by a simple ablative polymerization method; small amount of polymer-based agent injected endovenously by a small injector system
Biolas
Evlas Circular
Laser
1,470
–
–
Endovenous laser treatment method depends on the principle of closing the damaged vein by generating laser energy inside the vein with minimally invasive surgery, rather than removing the leaking vessel with traditional surgery; after surgery, there won't be any leakage into the varicose veins and visible varicose veins will shrink and disappear; as soon as the damaged vein is treated, healthy veins will provide venous circulation
F Care Systems
EVRF
Radiofrequency
–
1 (gauge 20, 24)
14, 120
CR45- GSV; CR12- Reticular Perforator Colaterall up to 2 mm and up to 6 mm for C4 30
Invamed
Filler
Polymer (n-BCA)
–
6
90
Treatment of iliac artery aneurysms, AAAs, and endoleaks using polymer n-BCA
Dornier MedTech GmbH
FlexiPulse
Laser
940
–
–
–
Total Vein Systems
Introducer Kits
Introducer kit
–
4, 5, 6, 7
7, 11, 20, 25, 35, 45, 55, 65, 85
Arterial and venous procedures requiring percutaneous introduction of intravascular devices
Total Vein Systems
Laser Fibers
Laser
Argon, KTP/532, Ho:YAG, Nd:YAG, 1.44Y AG, and Diode (532–2,100 nm)
–
–
Deliver laser light to soft tissue in the contact and noncontact mode during surgical procedures including via endoscopes and cystoscopes
Dornier MedTech GmbH
LiteBeam +
Laser
1,470
–
–
–
AngioDynamics
NeverTouch
Procedure kit
All
4
25, 45, 65, 90
Endovascular coagulation of the great saphenous vein in patients with superficial vein reflux, for the treatment of varicose veins and varicosities associated with superficial reflux of the great saphenous vein, and for the treatment of incompetence and reflux of superficial veins of the lower extremity
AngioDynamics
NeverTouch Direct
Procedure kit
All
600 µm
10
Treatment of varicose veins and varicosities associated with superficial vein reflux of the great saphenous vein and for the treatment of incompetent refluxing veins in the superficial venous system in the lower limb
iMS GmbH
simLa6
Laser
1,940
–
–
A surgical laser system for endovenous laser treatment (treatment of varicosis) in phlebology/vascular surgery; used in conjunction with the approved applicator fibers which are typically introduced directly into the veins/varicose veins to be treated using so-called introducers; indicated for the coagulation of the soft tissue/the denaturing of collagen in the vein (wall); the objective is the permanent sclerosing/occlusion of constricted leg veins; minimally invasive thermal treatment of varicose veins using primarily glass fibers applicators of varying external diameters that emit radially
AngioDynamics
Spotlight OPS
Procedure kit
All
4
25, 55, 80
Treatment of varicose veins and varicosities associated with superficial vein reflux of the great saphenous vein and with the treatment of incompetent refluxing veins in the superficial venous system in the lower limb
Treatment of the great saphenous vein and the small saphenous vein; no generator is needed; disposable
Total Vein Systems
TVS 1470
Laser
1,470 (15 watt)
–
–
Surgical applications requiring the vaporization, incision, excision, ablation, cutting, and hemostasis, or coagulation of soft tissue in conjunction with endoscopic equipment
Total Vein Systems
TVS 1470 Nano
Laser
1,470 (7 watt)
–
–
Surgical applications requiring the vaporization, incision, excision, ablation, cutting, and hemostasis, or coagulation of soft tissue in conjunction with endoscopic equipment
Biolas
VariClose
Vein sealing system
–
6
90
Embolization polymer that is indicated for ablation by polymerization of saphenous vein (vena saphena magna, valve saphenous parva) or perforator veins in endovenous treatment of incompetent lower-extremity varicose veins
Invamed
Veinoff
Polymer
–
–
–
Treatment of varicose veins (tributary veins) by a simple ablative polymerization method; small amounts of polymer (OCA) injected endovenously by a butterfly catheter and small injector system
Invamed
VenaBlock
Delivery system
–
6
90
Treatment of venous insufficiency; indicated for use in the permanent closure of lower extremity superficial truncal veins, such as the great saphenous vein and perforator vein, continuously while applying pressure over the target vein segment
Invamed
VenaBlock Automated System
Delivery system
–
6
200
Treatment of venous insufficiency; indicated for use in the permanent closure of lower extremity superficial truncal veins, such as the great saphenous vein and perforator vein, continuously while applying pressure over the target vein segment automatically
AngioDynamics
VenaCure 1470
Laser
1,470
–
–
Treatment of varicose veins and varicosities with superficial reflux of the greater saphenous vein and in the treatment of incompetent refluxing veins in the superficial venous system in the lower limb
Medtronic
VenaSeal Closure System
Nonthermal, nontumescent: cyanoacrylate-based medical adhesive
–
Access with 5-F microintroducer; blue introducer (ID: 5, OD: 7) included in kit
80 (blue introducer included)
Intended for the permanent, complete, endovascular adhesive closure of the great saphenous vein and associated varicosities in the treatment of venous reflux disease
BD Interventional
Venclose Radiofrequency Generator
Radiofrequency
–
–
–
Intended for endovascular coagulation of blood vessels in patients with superficial vein reflux
BD Interventional
Venclose RF Ablation System
Radiofrequency
Adjustable heating length (2.5 cm/10 cm)
6 (with working length of 60 cm and 100 cm)
7, 12
Intended for endovascular coagulation of blood vessels in patients with superficial vein reflux
STARmed Co., Ltd.
VeniStar 3 cm Endovenous Radiofrequency Ablation (RFA) Electrode
Radiofrequency
0–3 cm active tip length
7 (with 65 cm working length)
7, 11
Disposable hand-held electrode for electrosurgical instrument is intended for coagulation of tissue and blood vessel during endoscopic, percutaneous, laparoscopic, and intraoperative surgical procedures
STARmed Co., Ltd.
VeniStar 7 cm Endovenous Radiofrequency Ablation (RFA) Electrode
Radiofrequency
3–7 cm active tip length
7 (with 65 cm working length)
7, 11
Disposable hand-held electrode for electrosurgical instrument is intended for coagulation of tissue and blood vessel during endoscopic, percutaneous, laparoscopic, and intraoperative surgical procedures
STARmed Co., Ltd.
VVR RF System
Radiofrequency
–
–
–
Intended for use with the VeniStar electrode (3, 7 cm)
Advertisement
Advertisement
We value keeping the Device Guide up to date.
If you want to add or update your company’s device listings, please let us know!