Vesalio Inc.
5800 Granite Parkway, Suite 470 Plano, TX 75024
PHONE: (615) 206-7788
Stents / Self-Expanding Stents
View Chart| Company Name | Product Name | Material Used | Introducer Size (F) | Guidewire Compatibility (inch) | Stent Diameter (mm) | Stent Length (mm) | Delivery System Length (cm) | CE Mark Indications |
|---|---|---|---|---|---|---|---|---|
| Vesalio Inc. | NeVa VS - Vasospasm Treatment Device | Nitinol | Can be delivered through catheters with minimum ID of 0.021 inch (1.6 F) | Max: 0.018 | 4 | Full length: 35mm; working length: 30mm (excluding the 5-mm tip) | 200 | Endovascular treatment of cerebral vasospasm after aneurysmal SAH |
Advertisement
Advertisement
Other Devices / Mechanical Thrombectomy (Neurovascular)
View Chart| Company Name | Product Name | Sheath Compatibility (F) | Guidewire Compatibility (inch) | Working Length (cm) | Mode of Operation | CE Mark Indications |
|---|---|---|---|---|---|---|
| Vesalio Inc. | NeVa Thrombectomy System 4.0 X 22 mm | Minimum microcatheter ID: 0.021 (1.6 F) | Max: 0.018 | Basket working length: 22 mm, basket full length: 39 mm, pusher wire length: 200 cm | 2 drop zones for clot retrieval in acute ischemic stroke | Endovascular temporary use to restore blood flow in patients who are experiencing symptoms of acute ischemic stroke caused by an embolus in a cerebral vessel; Indicated for vessels with diameter > 2.0 mm and ≤ 3.5 mm |
| Vesalio Inc. | NeVa Thrombectomy System 4.5 X 29 mm | Minimum microcatheter ID: 0.021 (1.6 F) | Max: 0.018 | Basket working length: 29 mm, basket full length: 46 mm, pusher wire length: 200 cm | 3 drop zones for clot retrieval in acute ischemic stroke | Endovascular temporary use to restore blood flow in patients who are experiencing symptoms of acute ischemic stroke caused by an embolus in a cerebral vessel; Indicated for vessels with diameter > 2.0 mm and ≤ 4.5 mm |
| Vesalio Inc. | NeVa Thrombectomy System 5.5 X 37 mm | Minimum microcatheter ID: 0.027 (2.06 F) | Max: 0.018 | Basket working length: 37 mm, basket full length: 56 mm, pusher wire length: 200 cm | 3 drop zones for clot retrieval in acute ischemic stroke | Endovascular temporary use to restore blood flow in patients who are experiencing symptoms of acute ischemic stroke caused by an embolus in a cerebral vessel; Indicated for vessels with diameter > 3.5 mm and ≤ 5.5 mm |
| Vesalio Inc. | NeVa NET Thrombectomy System 4.0 X 30 mm | Minimum microcatheter ID: 0.021 (1.6 F) | Max: 0.018 | Basket working length: 30 mm; basket full length: 49 mm; pusher-wire length: 200 cm | 3 drop zones for clot retrieval in acute ischemic stroke; incorporates a braided net on the inside at the distal end of the expandable tip | Endovascular temporary use to restore blood flow in patients who are experiencing symptoms of acute ischemic stroke caused by an embolus in a cerebral vessel; indicated for vessels with diameter > 2.0 mm and ≤ 3.5 mm |
| Vesalio Inc. | NeVa NET Thrombectomy System 5.5 X 37 mm | Minimum microcatheter ID: 0.027 (2.06 F) | Max: 0.018 | Basket working length: 37 mm; basket full length: 56 mm; pusher-wire length: 200 cm | 3 drop zones for clot retrieval in acute ischemic stroke; incorporates a braided net on the inside at the distal end of the expandable tip | Endovascular temporary use to restore blood flow in patients who are experiencing symptoms of acute ischemic stroke caused by an embolus in a cerebral vessel; Indicated for vessels with diameter > 3.5 mm and ≤ 5.5 mm |
| Vesalio Inc. | NeVa Thrombectomy System 3.0 X 17 mm | Minimum microcatheter ID: 0.017 (1.3 F) | Max: 0.014 | Basket working length: 17 mm, basket full length: 30 mm, pusher wire length: 200 cm | 2 drop zones for clot retrieval in acute ischemic stroke | Endovascular temporary use to restore blood flow in patients who are experiencing symptoms of acute ischemic stroke caused by embolus in a cerebral vessel |
More Categories:
Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View AllAdvertisement