Vesalio Inc.

5800 Granite Parkway, Suite 470 Plano, TX 75024

PHONE: (615) 206-7788

down-arrow Created with Sketch.
down-arrow Created with Sketch.

Stents / Self-Expanding Stents

View Chart
Company Name Product Name Material Used Introducer Size (F) Guidewire Compatibility (inch) Stent Diameter (mm) Stent Length (mm) Delivery System Length (cm) US FDA Indicated Use
Vesalio Inc. NeVa VS - Vasospasm Treatment Device Nitinol Can be delivered through catheters with minimum ID of 0.021 inch (1.6 F) Max: 0.018 4 Full length: 35 mm; working length: 30 mm (excluding the 5-mm tip) 200 Endovascular treatment of cerebral vasospasm after aneurysmal SAH

Advertisement

Advertisement

Other Devices / Mechanical Thrombectomy/Thrombolysis (Peripheral/Venous)

View Chart
Company Name Product Name Sheath Compatibility (F) Guidewire Compatibility (inch) Working Length (cm) Mode of Operation US FDA Indicated Use
Vesalio Inc. pVasc Thrombectomy System 4.0 x 30 mm Can be delivered through catheters with ID as small as 0.021 inch (1.6 F); also compatible with 0.035 inch (2.67 F) 0.018 Device basket working length: 30 mm; full length: 48 mm; pusher wire length: 200 cm Delivered via a catheter (ID can be as small as .021", also compatible with .035"); deployed at the occlusion site, on or beyond the clot, the flow restoration zone re-establishes flow to distal territory and engages softer clots; drop zones capture all clots, including organized varieties; once thrombus integrated, the closed distal tip helps retain it during retrieval; pVasc can be used alone or with adjunctive therapy (compatible with coaspiration); work time is not limited by blood loss Indicated for use in vessels ≥ 2 and ≤ 3.5 mm in diameter
Vesalio Inc. pVasc Thrombectomy System 6.0 x 44 mm Can be delivered through catheters with ID as small as 0.027 inch (2.06 F); also compatible with 0.035 inch (2.67 F) 0.018 Device basket working length: 44 mm; full length: 63 mm; pusher wire length: 200 cm Delivered via a catheter (ID can be as small as .027", also compatible with .035"); deployed at the occlusion site, on or beyond the clot, the flow restoration zone re-establishes flow to distal territory and engages softer clots; drop zones capture all clots, including organized varieties; once thrombus integrated, the closed distal tip helps retain it during retrieval; pVasc can be used alone or with adjunctive therapy (compatible with coaspiration); work time is not limited by blood loss Indicated for use in vessels ≥ 3.5 and ≤ 6 in diameter
Vesalio Inc. pVasc Thrombectomy System 4.0 x 38 mm Can be delivered through catheters with ID as small as 0.021 inch (1.6 F); also compatible with 0.035 inch (2.67 F) 0.018 Device basket working length: 38 mm; full length: 55 mm; pusher wire length: 200 cm Delivered via a catheter (ID can be as small as .021 inch, also compatible with .035 inch); deployed at the occlusion site, on or beyond the clot, the flow restoration zone re-establishes flow to distal territory and engages softer clots; drop zones capture all clots, including organized varieties; once thrombus is integrated, the closed distal tip helps retain it during retrieval; pVasc can be used alone or with adjunctive therapy (compatible with coaspiration); work time is not limited by blood loss Indicated for use in vessels ≥ 2 and ≤ 3.5 mm in diameter

More Categories:

Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View All

Advertisement

Latest News


May 4, 2026

ENGULF Analysis Shows Reduced Blood Loss With E2’s Hēlo System in PE Procedures

May 1, 2026

FDA Awards IDE for Pivotal Study of enVVeno’s Venous Valve to Treat Severe Deep CVI

April 29, 2026

Cydar Maps Planning and Navigation Solution Expanded to Enable Use in Complex Branched and Visceral Cases

Most Read Articles


Update on Modern Complex Abdominal Aortic Repair Options

With Jason T. Lee, MD; Steven Maximus, MD, FACS; Gustavo Oderich, MD, FACS; Benjamin W. Starnes, MD, FACS; Carlos Timaran, MD; Kak Khee Yeung, MD, PhD, FEBVS; and Javairiah Fatima, MD, FACS, DFSVS

A Private Practice Physician’s Experience Treating Chronic Venous Insufficiency

By Robert A. Edwards, DO

Addressing Pelvic Venous Disease With a New Class of Coils

With Gloria Salazar, MD, FSIR; Ronald Winokur, MD, FSIR, RPVI; Marissa Famularo, DO; Eric Hager, MD; Driss Raissi, MD, MBA, FSIR; and Brian Do, DO

Back to Top
Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous
Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

News• Current Issue• Archive• Device Guide• Advertising• About Calendar• Contact• Privacy• Submissions• Subscriptions


Endovascular Today (ISSN 1551-1944 print and ISSN 2689-792X online) is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field.



magazine Created with Sketch.

Free Print Subscriptions

Fill 1 Created with Sketch.

Email Newsletter



twitter-icon LinkedIn Created with Sketch. instagram BlueSky-Circle
Cardiac Interventions Today
Group 7 Copy 3 Created with Sketch.
bmc-secondary-mark-color copy Created with Sketch.

© 2026 Bryn Mawr Communications II, LLC.  
All Rights Reserved   •   Privacy Policy

one-trust-button