Stents / Self-Expanding Stents
View Chart| Company Name | Product Name | Material Used | Introducer Size (F) | Guidewire Compatibility (inch) | Stent Diameter (mm) | Stent Length (mm) | Delivery System Length (cm) | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|---|
| Vesalio Inc. | NeVa VS - Vasospasm Treatment Device | Nitinol | Can be delivered through catheters with minimum ID of 0.021 inch (1.6 F) | Max: 0.018 | 4 | Full length: 35 mm; working length: 30 mm (excluding the 5-mm tip) | 200 | Endovascular treatment of cerebral vasospasm after aneurysmal SAH |
Advertisement
Advertisement
Other Devices / Mechanical Thrombectomy/Thrombolysis (Peripheral/Venous)
View Chart| Company Name | Product Name | Sheath Compatibility (F) | Guidewire Compatibility (inch) | Working Length (cm) | Mode of Operation | US FDA Indicated Use |
|---|---|---|---|---|---|---|
| Vesalio Inc. | pVasc Thrombectomy System 4.0 x 30 mm | Can be delivered through catheters with ID as small as 0.021 inch (1.6 F); also compatible with 0.035 inch (2.67 F) | 0.018 | Device basket working length: 30 mm; full length: 48 mm; pusher wire length: 200 cm | Delivered via a catheter (ID can be as small as .021", also compatible with .035"); deployed at the occlusion site, on or beyond the clot, the flow restoration zone re-establishes flow to distal territory and engages softer clots; drop zones capture all clots, including organized varieties; once thrombus integrated, the closed distal tip helps retain it during retrieval; pVasc can be used alone or with adjunctive therapy (compatible with coaspiration); work time is not limited by blood loss | Indicated for use in vessels ≥ 2 and ≤ 3.5 mm in diameter |
| Vesalio Inc. | pVasc Thrombectomy System 6.0 x 44 mm | Can be delivered through catheters with ID as small as 0.027 inch (2.06 F); also compatible with 0.035 inch (2.67 F) | 0.018 | Device basket working length: 44 mm; full length: 63 mm; pusher wire length: 200 cm | Delivered via a catheter (ID can be as small as .027", also compatible with .035"); deployed at the occlusion site, on or beyond the clot, the flow restoration zone re-establishes flow to distal territory and engages softer clots; drop zones capture all clots, including organized varieties; once thrombus integrated, the closed distal tip helps retain it during retrieval; pVasc can be used alone or with adjunctive therapy (compatible with coaspiration); work time is not limited by blood loss | Indicated for use in vessels ≥ 3.5 and ≤ 6 in diameter |
| Vesalio Inc. | pVasc Thrombectomy System 4.0 x 38 mm | Can be delivered through catheters with ID as small as 0.021 inch (1.6 F); also compatible with 0.035 inch (2.67 F) | 0.018 | Device basket working length: 38 mm; full length: 55 mm; pusher wire length: 200 cm | Delivered via a catheter (ID can be as small as .021 inch, also compatible with .035 inch); deployed at the occlusion site, on or beyond the clot, the flow restoration zone re-establishes flow to distal territory and engages softer clots; drop zones capture all clots, including organized varieties; once thrombus is integrated, the closed distal tip helps retain it during retrieval; pVasc can be used alone or with adjunctive therapy (compatible with coaspiration); work time is not limited by blood loss | Indicated for use in vessels ≥ 2 and ≤ 3.5 mm in diameter |
Other Devices / Thrombus Aspiration Devices
View Chart| Company Name | Product Name | Type | Maximum Tip Diameter (mm) | Minimum Guide Catheter Size (F) | Catheter Length (cm) |
|---|---|---|---|---|---|
| Vesalio Inc. | pVasc AC Endovascular Thrombectomy System | Aspiration catheter intended for use in conjunction with the pVasc Thrombectomy retrieval device | 2.16 | 6.5 | Working length: 132 mm |
More Categories:
Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View AllAdvertisement