Advertisement
Advertisement
Mechanical Thrombectomy/Thrombolysis (Peripheral/Venous)
76 products
All Columns
| Compare | Company Name | Product Name | Sheath Compatibility (F) | Guidewire Compatibility (inch) | Working Length (cm) | Mode of Operation | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|
| AngioDynamics | AlphaVac F18 System | 22 | 0.038 | 105 | Multipurpose mechanical aspiration | The F1885 cannula is indicated for the nonsurgical removal of thrombi or emboli from the vasculature; aspiration of contrast media and other fluids from the vasculature; intended for use in the venous system and for the treatment of pulmonary embolism; the handle is indicated as a vacuum source for the AlphaVac Multipurpose Mechanical Aspiration System | |
| AngioDynamics | AlphaVac F22 System | 25 | 0.038 | 77 | Multipurpose mechanical aspiration | Indicated for the nonsurgical removal of thrombi or emboli from the vasculature and aspiration of contrast media and other fluids from the vasculature; the cannula is intended for use in the venous system; the AlphaVac Handle is indicated as a vacuum source for the AlphaVac Multi-purpose Mechanical Aspiration System | |
| Boston Scientific Corporation | AngioJet AVX Thrombectomy Catheter | 6 | 0.035 | 50 | High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal | Breaking apart and removing thrombus from AV access conduits ≥ 3 mm in diameter | |
| Boston Scientific Corporation | AngioJet Solent Dista Thrombectomy Catheter | 4 | 0.014 | 145 | High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal | Breaking apart and removing thrombus from upper and lower extremity peripheral arteries ≥ 1.5 mm in diameter and for use with the AngioJet Ultra Power Pulse Kit for the control and selective infusion of physician specified fluids, including thrombolytic agents, into the peripheral vascular system | |
| Boston Scientific Corporation | AngioJet Solent Omni Thrombectomy Catheter | 6 | 0.035 | 120 | High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal | Breaking apart and removing thrombus from upper and lower extremity peripheral arteries, upper extremity peripheral veins, iliofemoral and lower extremity peripheral veins ≥ 3 mm in diameter, and for use with the AngioJet Ultra Power Pulse Kit for the control and selective infusion of physician specified fluids, including thrombolytic agents, into the peripheral vascular system | |
| Boston Scientific Corporation | AngioJet Solent Proxi Thrombectomy Catheter | 6 | 0.035 | 90 | High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal | Breaking apart and removing thrombus from upper and lower extremity peripheral arteries, upper extremity peripheral veins, iliofemoral and lower extremity peripheral veins ≥ 3 mm in diameter, and for use with the AngioJet Ultra Power Pulse Kit for the control and selective infusion of physician specified fluids, including thrombolytic agents, into the peripheral vascular system | |
| Boston Scientific Corporation | AngioJet ZelanteDVT Thrombectomy Catheter | 8 | 0.035 | 105 | High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal | The ZelanteDVT Thrombectomy System, which includes the ZelanteDVT Thrombectomy Set and the ClotHunter Helical Rotation Device, is intended for use with the AngioJet Ultra Console to break apart and remove thrombus, including deep vein thrombus (DVT), from (1) iliofemoral and lower extremity veins ≥ 6 mm in diameter and (2) upper extremity peripheral veins ≥ 6 mm in diameter; the ZelanteDVT Thrombectomy System is also intended for use with the AngioJet Ultra Power Pulse technique for the controlled and selective infusion of physician-specified fluids, including thrombolytic agents, into the peripheral vascular system | |
| Inari Medical | Artix Thrombectomy System | 8 | Covered funnel catheter, 0.035-inch guidewire compatible; MT thrombectomy device, 0.014-inch guidewire compatible | Sheath: 65, 90; covered funnel catheter: 76, 101; MT thrombectomy device: 130 | Dual mechanical and aspiration solution designed to address a broad spectrum of arterial thrombus cases | Two available sizes treats vessels 3–6 and 4–8 mm; the Artix Thin-Walled Sheath is indicated for: (1) the nonsurgical removal of emboli and thrombi from blood vessels; (2) injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel; (3) use as a conduit for endovascular devices; and (4) use in facilitating the insertion and guidance of an intravascular catheter into a selected blood vessel; the funnel provides temporary vascular occlusion during these and other angiographic procedures; the Artix Thin-Walled Sheath is intended for use in the peripheral vasculature; the Artix MT thrombectomy device is indicated for: (1) the nonsurgical removal of emboli and thrombi from a blood vessel; and (2) injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel; the Artix MT thrombectomy device is intended for use in the peripheral vasculature; the Artix AX aspiration catheter is indicated for (1) the nonsurgical removal of emboli and thrombi from blood vessels; and (2) injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel; the Artix AX aspiration catheter is intended for use in the peripheral vasculature; the FlowSaver Blood Return System is used with Inari Medical catheters and sheaths for autologous blood transfusion; refer to Instructions for Use for complete indications for use, contraindications, warnings, and precautions | |
| BD Interventional | Aspirex Mechanical Aspiration Thrombectomy System | 6, 8, 10 | 0.018, 0.025 | 85, 110, 135 | Aspiration | Indicated for the removal of acute emboli and thrombi from vessels of the peripheral venous system | |
| Inquis Medical | Aventus Thrombectomy System | 24 | 0.035 | 92 | Mechanical aspiration, intelligent tip with TrueClot sensing, integrated clot filtration and autologous blood return | The nonsurgical removal of emboli and thrombi from blood vessels; injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel; intended for use in the peripheral vasculature and for the treatment of pulmonary embolism | |
| Thrombolex, Inc. | Bashir .035 Endovascular Catheter | 8 | 0.035 | 92.5 | Restores blood flow by expanding the 12.5-cm length infusion basket that treats vessel diameters 3 to 45 mm; physician-specified fluids, including thrombolytics, can be pulse-sprayed or infused through 48 precision-drilled holes in the basket directly into the thrombus; the basket is opened by an actuator on the handle, and infusion fluids can be administered with a syringe or infusion pump into the basket | The Bashir .035 Endovascular Catheter is a mechanical thrombolysis catheter indicated for the controlled and selective infusion of physician-specified fluids, including thrombolytics, into the pulmonary arteries for treatment of pulmonary embolism; the catheter is also indicated for infusion of physician-specified fluids, including thrombolytics, into the peripheral vasculature, enabling the restoration of blood flow in patients with venous thrombus | |
| Thrombolex, Inc. | Bashir +10 Endovascular Catheter | 7 | 0.018 | 92.5 | Restores blood flow by expanding the 12.5-cm length infusion basket that treats vessel diameters 3 to 45 mm; physician-specified fluids, including thrombolytics, can be pulse-sprayed or infused through 48 precision-drilled holes in the basket directly into the thrombus; the basket is opened by an actuator on the handle, and infusion fluids can be administered with a syringe or infusion pump into the basket and along the catheter shaft | The Bashir Plus Endovascular Catheters (Bashir +10, Bashir +20, Bashir +30, Bashir +40) are intended for the controlled and selective infusion of physician-specified fluids, including thrombolytics, into the peripheral vasculature, enabling the restoration of blood flow in patients with venous thrombus | |
| Thrombolex, Inc. | Bashir +20 Endovascular Catheter | 7 | 0.018 | 92.5 | Restores blood flow by expanding the 12.5-cm length infusion basket that treats vessel diameters 3 to 45 mm; physician-specified fluids, including thrombolytics, can be pulse-sprayed or infused through 48 precision-drilled holes in the basket directly into the thrombus; the basket is opened by an actuator on the handle, and infusion fluids can be administered with a syringe or infusion pump into the basket and along the catheter shaft | The Bashir Plus Endovascular Catheters (Bashir +10, Bashir +20, Bashir +30, Bashir +40) are intended for the controlled and selective infusion of physician specified fluids, including thrombolytics, into the peripheral vasculature, enabling the restoration of blood flow in patients with venous thrombus | |
| Thrombolex, Inc. | Bashir +30 Endovascular Catheter | 7 | 0.018 | 92.5 | Restores blood flow by expanding the 12.5-cm length infusion basket that treats vessel diameters 3 to 45 mm; physician-specified fluids, including thrombolytics, can be pulse-sprayed or infused through 48 precision-drilled holes in the basket directly into the thrombus; the basket is opened by an actuator on the handle, and infusion fluids can be administered with a syringe or infusion pump into the basket and along the catheter shaft | The Bashir Plus Endovascular Catheters (Bashir +10, Bashir +20, Bashir +30, Bashir +40) are intended for the controlled and selective infusion of physician-specified fluids, including thrombolytics, into the peripheral vasculature, enabling the restoration of blood flow in patients with venous thrombus | |
| Thrombolex, Inc. | Bashir +40 Endovascular Catheter | 7 | 0.018 | 92.5 | Restores blood flow by expanding the 12.5-cm length infusion basket that treats vessel diameters 3 to 45 mm; physician-specified fluids, including thrombolytics, can be pulse-sprayed or infused through 48 precision-drilled holes in the basket directly into the thrombus; the basket is opened by an actuator on the handle, and infusion fluids can be administered with a syringe or infusion pump into the basket and along the catheter shaft | The Bashir Plus Endovascular Catheters (Bashir +10, Bashir +20, Bashir +30, Bashir +40) are intended for the controlled and selective infusion of physician-specified fluids, including thrombolytics, into the peripheral vasculature, enabling the restoration of blood flow in patients with venous thrombus | |
| Thrombolex, Inc. | Bashir Endovascular Catheter | 7 | 0.018 | 92.5 | Restores blood flow by expanding the 12.5-cm length infusion basket that treats vessel diameters 3 to 45 mm; physician-specified fluids, including thrombolytics, can be pulse-sprayed or infused through 48 precision-drilled holes in the basket directly into the thrombus; the basket is opened by an actuator on the handle, and infusion fluids can be administered with a syringe or infusion pump into the basket | The Bashir Endovascular Catheter is a mechanical thrombolysis catheter indicated for the controlled and selective infusion of physician-specified fluids, including thrombolytics, into the pulmonary arteries for treatment of pulmonary embolism; infusion of physician-specified fluids, including thrombolytics, into the peripheral vasculature, enabling the restoration of blood flow in patients with venous thrombus | |
| Thrombolex, Inc. | Bashir S-B .035 Endovascular Catheter | 8 | 0.035 | 92.5 | Restores blood flow by expanding the 10-cm length infusion basket that treats vessel diameters 3 to 39 mm; physician-specified fluids, including thrombolytics, can be pulse-sprayed or infused through 48 precision-drilled holes in the basket directly into the thrombus; the basket is opened by an actuator on the handle, and infusion fluids can be administered with a syringe or infusion pump into the basket. | The Bashir S-B .035 Endovascular Catheter is a mechanical thrombolysis catheter indicated for the controlled and selective infusion of physician-specified fluids, including thrombolytics, into the pulmonary arteries and for treatment of pulmonary embolism; the catheter is also indicated for the infusion of physician-specified fluids, including thrombolytics, into the peripheral vasculature, enabling the restoration of blood flow in patients with venous thrombus | |
| Thrombolex, Inc. | Bashir S-B Endovascular Catheter | 7 | 0.018 | 92.5 | Instantly restores blood flow by expanding the 10-cm length infusion basket that treats vessel diameters 3 to 39 mm; physician-specified fluids, including thrombolytics, can be pulse-sprayed or infused through 48 precision-drilled holes in the basket directly into the thrombus; the basket is opened by an actuator on the handle, and infusion fluids can be administered with a syringe or infusion pump into the basket | The Bashir Endovascular Catheter is a mechanical thrombolysis catheter indicated for the controlled and selective infusion of physician-specified fluids, including thrombolytics, into the pulmonary arteries for treatment of pulmonary embolism; infusion of physician-specified fluids, including thrombolytics, into the peripheral vasculature, enabling the restoration of blood flow in patients with venous thrombus | |
| Argon Medical Devices, Inc. | Cleaner 15 | 7 | – | 65, 135 | Battery-operated, handheld drive unit initiates the mechanical rotation of an atraumatic, wall-contacting, 15-mm sinusoidal vortex wire for effective thrombus maceration | Indicated for mechanical declotting and controlled and selective infusion of physician-specified fluids, including thrombolytics, in the peripheral vasculature; also indicated for mechanical declotting of native vessel dialysis fistulas and synthetic dialysis access grafts | |
| Argon Medical Devices, Inc. | Cleaner Vac Thrombectomy System | 18 | 0.038 | 115 | Battery-operated, user-controlled power aspiration thrombectomy | Indicated for the removal of fresh, soft thrombi and emboli from the vessels of the peripheral venous vasculature, and for the infusion of physician-specified fluids, including thrombolytics | |
| Argon Medical Devices, Inc. | Cleaner XT | 6 | – | 65, 135 | Battery-operated, handheld drive unit initiates the mechanical rotation of an atraumatic, wall-contacting, 9-mm sinusoidal vortex wire for effective thrombus maceration | Indicated for mechanical declotting and controlled and selective infusion of physician-specified fluids, including thrombolytics, in the peripheral vasculature; also indicated for mechanical declotting of native vessel dialysis fistulas and synthetic dialysis access grafts | |
| Inari Medical | ClotTriever Thrombectomy System | 13, 16 | 0.035 | 80 | Mechanical coring, collection, and retrieval of emboli and thrombi | The nonsurgical removal of thrombi and emboli from blood vessels; injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel; intended for use in the peripheral vasculature including deep vein thrombosis | |
| Control Medical Technology | Control 11F Mechanical Thrombectomy System | 11 | 0.035 | 90 | Mechanical aspirator, 11-F catheter, and dilator | Indicated for the removal of fresh, soft emboli and thrombi from vessels in the peripheral vasculature | |
| Control Medical Technology | Control 5F Mechanical Thrombectomy System | 5 | 0.035 | 135 | Mechanical aspirator, 5-F catheter, and dilator | Indicated for the removal of fresh, soft emboli and thrombi from vessels in the peripheral vasculature | |
| Control Medical Technology | Control 6F Mechanical Thrombectomy System | 6 | 0.035 | 135 | Mechanical aspirator, 6-F catheter, and dilator | Indicated for the removal of fresh, soft emboli and thrombi from vessels in the peripheral vasculature | |
| Control Medical Technology | Control 7F Mechanical Thrombectomy System | 7 | 0.035 | 90 | Mechanical aspirator, 7-F catheter, and dilator | Indicated for the removal of fresh, soft emboli and thrombi from vessels in the peripheral vasculature | |
| Control Medical Technology | Control 8F Mechanical Thrombectomy System | 8 | 0.035 | 90 | Mechanical aspirator, 8-F catheter, and dilator | Indicated for the removal of fresh, soft emboli and thrombi from vessels in the peripheral vasculature | |
| Control Medical Technology | Control Mechanical Aspirator | Any sheath | Any wire | Any length | Mechanical thrombectomy drive unit, continuous and/or pulsed mechanical thrombectomy | Indicated to aspirate fluids from the body and the removal of fresh, soft emboli and thrombi from vessels in the peripheral and coronary vasculature | |
| Control Medical Technology | Control RX-LP Mechanical Thrombectomy System | 5-F sheath or 6-F guide catheter | 0.014 | 136 | Mechanical thrombectomy | Indicated for removal of fresh, soft emboli and thrombi from vessels in the peripheral and coronary vasculature | |
| Mermaid Medical | D*Clot HD Thrombectomy System | 6 | – | 65 | Disposable system consists of an outer sheath through which a rotatable radiopaque spiral shaft extends ending in an eccentric blunt distal tip; the shaft rotates at 10,000 rpm to break thrombus into smaller particles, which can be simultaneously aspirated using a dedicated vacuum syringe | Indicated for mechanical declotting of native vessel dialysis fistulae and synthetic dialysis access grafts | |
| Boston Scientific Corporation | Ekos Endovascular System | 6 | 0.035 | 106 (treatment areas: 6, 12, 18, 24, 30, 40, 50); 135 (treatment areas: 12, 30, 40, 50) | The treatment offers a minimally invasive system for the acceleration of thrombus dissolution; the ultrasonic core generates a localized acoustic field that targets the entire thrombus; this greatly accelerates lytic dispersion by driving the drug deeper into the clot and unwinding the fibrin to expose plasminogen receptor sites | Indicated for the ultrasound-facilitated, controlled, and selective infusion of physician-specified fluids, including thrombolytics, into the vasculature for the treatment of pulmonary embolism and/or deep vein thrombosis; the controlled and selective infusion of physician-specified fluids, including thrombolytics, into the peripheral vasculature; and the infusion of solutions into the pulmonary arteries | |
| Boston Scientific Corporation | Ekos+ Endovascular System | 8 | 0.035 | 106 (treatment areas: 8, 12, 16, 20); 135 (treatment areas: 8, 12, 16, 20) | The treatment offers a minimally invasive system for the acceleration of thrombus dissolution; the ultrasonic core generates a localized acoustic field that targets the entire thrombus; this greatly accelerates lytic dispersion by driving the drug deeper into the clot and unwinding the fibrin to expose plasminogen receptor sites | Indicated for the ultrasound-facilitated, controlled, and selective infusion of physician-specified fluids, including thrombolytics, into the vasculature for the treatment of pulmonary embolism and/or deep vein thrombosis; the controlled and selective infusion of physician-specified fluids, including thrombolytics, into the peripheral vasculature; and the infusion of solutions into the pulmonary arteries | |
| Contego Medical LLC | Excipio LV (Large Vessel) | 12.6 | 0.035 | 125 | The Excipio LV Thrombectomy Device is a rapid exchange catheter with an integrated nitinol braided basket designed to mechanically displace thrombus | Indicated for the nonsurgical removal of emboli and thrombi from peripheral blood vessels | |
| Contego Medical LLC | Excipio SV (Small Vessel) | 7 | 0.014 | 165 | The Excipio SV Thrombectomy Device is a sterile, single-use catheter consisting of a catheter with an integrated nitinol braided basket designed to mechanically displace thrombus | Indicated for the nonsurgical removal of soft emboli and thrombi from peripheral blood vessels | |
| Inari Medical | FlowTriever Catheter (disks) - FlowTriever Retrieval/Aspiration System | 20, 22 | 0.035 | 115 | Mechanical and aspirational disruption, fragmentation, maceration, and retrieval of emboli and thrombi | The nonsurgical removal of emboli and thrombi from blood vessels, and injection, infusion and/or aspiration of contrast media and other fluids into or from a blood vessel; the FlowTriever System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism; Triever catheters are intended for use in treating clot in transit in the right atrium, but not in conjunction with FlowTriever catheters | |
| Inari Medical | FlowTriever2 Catheter (disks) - FlowTriever Retrieval/Aspiration System | 20, 22, 24, 26 | 0.035 | 120 | Mechanical and aspirational disruption, fragmentation, maceration, and retrieval of emboli and thrombi | The nonsurgical removal of emboli and thrombi from blood vessels, and injection, infusion and/or aspiration of contrast media and other fluids into or from a blood vessel; FlowTriever2 is intended for use in the peripheral vasculature | |
| ICHOR Vascular Inc. | ICHOR 14 | 14 F (part of the system) | 0.035 | 12, 55, 100 | Removal of vascular occlusions using a semicompliant balloon as the primary "wall-contact" mechanism of action (MOA) with supportive aspiration to sweep, aspirate, or snare thrombus, acute clot, subchronic, or adherent material into the extraction funnel; the "control sheath" has an occlusion balloon to arrest flow/maximize clot removal, while reducing distal embolization; the system equally has the ability to "agitate" to remove more chronic clot using the same MOA to safely remove debris | Indicated for the nonsurgical removal of emboli and thrombi from blood vessels; intended for the peripheral vasculature and is not intended for use in the coronary or neurovasculature | |
| ICHOR Vascular Inc. | ICHOR 7 | 7 F (part of the system) | 0.014 | 50, 90, 155 | Removal of vascular occlusions using a compliant Rx balloon as the primary mechanism of action with supportive aspiration to sweep, aspirate or snare thrombus, acute clot, or embolic material into the extraction funnel; the "control sheath" has an occlusion balloon to arrest flow and maximize clot removal, while reducing distal embolization | Indicated for the nonsurgical removal of emboli and thrombi from blood vessels; intended for the peripheral vasculature and is not intended for use in the coronary or neurovasculature | |
| Penumbra, Inc. (Peripheral Vascular) | Indigo System Catheter CAT RX | 6 (guide catheter) | 0.014 | 140 | The Indigo System CAT RX is paired with the Penumbra ENGINE to provide sustained, powerful aspiration | As part of the Indigo Aspiration System, the Indigo CAT RX Aspiration Catheters and Indigo Separator 4 are indicated for the removal of fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature | |
| Penumbra, Inc. (Peripheral Vascular) | Indigo System Catheters: CAT7D, CAT6, and CAT RX | 7 (CAT7D); 6 (CAT6); 6F guide catheter (CAT RX) | 0.014–0.038 | 50–150 | The Indigo System Catheters are paired with the Penumbra ENGINE for continuous, powerful aspiration | Indigo aspiration catheters and separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems and for the treatment of pulmonary embolism; as part of the Indigo aspiration system, the Indigo Sterile aspiration tubing is indicated to connect the Indigo aspiration catheters to the Penumbra aspiration pump; as part of the Indigo aspiration system, the Indigo CAT RX aspiration catheters and Indigo Separator 4 are indicated for the removal of fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature | |
| Penumbra, Inc. (Peripheral Vascular) | Indigo System Catheters: Lightning Bolt 12 | 12 | 0.014–0.038 | 100–115 | The Lightning Bolt Aspiration Tubing (Indigo Aspiration Tubing) is designed to serve as a conduit to assist in thrombus removal, facilitating transfer of vacuum between the Penumbra Aspiration Pump and the Indigo Aspiration Catheter while providing intermittent, continuous, or modulated aspiration; modulated aspiration is provided when the Lightning Bolt Aspiration Tubing alternates between connecting the Indigo Aspiration Catheter to the Penumbra Aspiration Pump and a sterile saline intravenous bag at ambient pressure | The Indigo Aspiration Catheters and Separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems and for the treatment of pulmonary embolism; as part of the Indigo Aspiration System, the Indigo Sterile Aspiration Tubing is indicated to connect the Indigo Aspiration Catheters to the Penumbra Aspiration Pump | |
| Penumbra, Inc. (Peripheral Vascular) | Indigo System Catheters: Lightning Bolt 6X with TraX | 6 | 0.014 | 132, 150 | The Lightning Bolt Aspiration Tubing (Indigo Aspiration Tubing) is designed to serve as a conduit to assist in thrombus removal, facilitating transfer of vacuum between the Penumbra Aspiration Pump and the Indigo Aspiration Catheter while providing intermittent, continuous, or modulated aspiration; modulated aspiration is provided when the Lightning Bolt Aspiration Tubing alternates between connecting the Indigo Aspiration Catheter to the Penumbra Aspiration Pump and a sterile saline intravenous bag at ambient pressure | The Indigo Aspiration Catheters and Separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems and for the treatment of pulmonary embolism. As part of the Indigo Aspiration System, the Indigo Sterile Aspiration Tubing is indicated to connect the Indigo Aspiration Catheters to the Penumbra Aspiration Pump | |
| Penumbra, Inc. (Peripheral Vascular) | Indigo System Catheters: Lightning Bolt 7 | 7 | 0.014–0.038 | 130 | The Lightning Bolt Aspiration Tubing (Indigo Aspiration Tubing) is designed to serve as a conduit to assist in thrombus removal, facilitating transfer of vacuum between the Penumbra Aspiration Pump and the Indigo Aspiration Catheter while providing intermittent, continuous, or modulated aspiration; modulated aspiration is provided when the Lightning Bolt Aspiration Tubing alternates between connecting the Indigo Aspiration Catheter to the Penumbra Aspiration Pump and a sterile saline intravenous (IV) bag at ambient pressure | The Indigo Aspiration Catheters and Separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems and for the treatment of pulmonary embolism; as part of the Indigo Aspiration System, the Indigo Sterile Aspiration Tubing is indicated to connect the Indigo Aspiration Catheters to the Penumbra Aspiration Pump | |
| Penumbra, Inc. (Peripheral Vascular) | Indigo System Catheters: Lightning Flash 2.0 with Select + | 16 | 0.014–0.038 | 80–115 | Lightning Flash Aspiration Tubing facilitates the transfer of vacuum between CAT16 Aspiration Catheter and Penumbra Aspiration Pump while providing intermittent or continuous aspiration. Intended users for this device are physicians who have received appropriate training in interventional techniques .The Indigo Lightning Flash Aspiration System is kitted with the Select + Catheter. The Select + Catheter is used to aide in tracking the aspiration catheter to the site of occlusion and is removed prior to initiating aspiration with the aspiration catheter | Indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems and for the treatment of pulmonary embolism; as part of the Indigo Aspiration System, the Indigo Sterile Aspiration Tubing is indicated to connect the Indigo Aspiration Catheters to the Penumbra Aspiration Pump | |
| Penumbra, Inc. (Peripheral Vascular) | Indigo System Separator SEPC4 | – | – | 200 | Separator-assisted clot debulking, if needed | As part of the Indigo Aspiration System, the Indigo CAT RX Aspiration Catheters and Indigo Separator 4 are indicated for the removal of fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature | |
| Penumbra, Inc. (Peripheral Vascular) | Indigo System Separators: SEP12, SEP7, SEP7D, SEP6, SEP5, SEPC4 | – | – | 90–200 | The device is advanced and retracted through the Indigo catheter at the proximal margin of the primary occlusion to facilitate clearing of the thrombus from the catheter tip, as needed | The Indigo aspiration catheters and separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems and for the treatment of pulmonary embolism; as part of the Indigo aspiration system, the Indigo CAT RX aspiration catheters and Indigo Separator 4 are indicated for the removal of fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature | |
| Innova Vascular, Inc. | Laguna Thrombectomy System | 10, 12 | 0.035 | 140 | Removal of clot using Laguna Clot Retriever and Malibu aspiration catheter | Indicated for the nonsurgical removal of emboli and thrombi from blood vessels; injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel; intended for use in the peripheral vasculature | |
| Medtronic | Liberant Thrombectomy System | 12 | 0.035 | 115 | Mechanical aspiration | Peripheral arterial and venous systems | |
| Medtronic | Liberant Thrombectomy System | 8 | 0.035 | 115 | Mechanical aspiration | Peripheral arterial and venous systems | |
| Medtronic | Liberant Thrombectomy System | 8 | 0.035 | 50 | Mechanical aspiration | Peripheral arterial and venous systems | |
| Medtronic | Liberant Thrombectomy System | 6 | 0.035 | 135 | Mechanical aspiration | Peripheral arterial and venous systems | |
| Innova Vascular, Inc. | Malibu Aspiration Catheter System | 16 | 0.035 | 107 | Aspiration using a 60-mL syringe (supplied with the product) | Indicated for the nonsurgical removal of emboli and thrombi from blood vessels; injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel; intended for use in the peripheral vasculature | |
| Innova Vascular, Inc. | Malibu Aspiration Catheter System | 24 | 0.035 | 90 | Aspiration using a 60-mL syringe (supplied with the product) | Indicated for the nonsurgical removal of emboli and thrombi from blood vessels; injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel; intended for use in the peripheral vasculature | |
| Innova Vascular, Inc. | Malibu Aspiration Catheter System | 12 | 0.035 | 115 | Aspiration using a 60-mL syringe (supplied with the product) | Indicated for the nonsurgical removal of emboli and thrombi from blood vessels; injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel; intended for use in the peripheral vasculature | |
| Innova Vascular, Inc. | Malibu Aspiration Catheter System | 20 | 0.035 | 100 | Aspiration using a 60-mL syringe (supplied with the product) | Indicated for the nonsurgical removal of emboli and thrombi from blood vessels; injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel; intended for use in the peripheral vasculature | |
| Cook Medical | Multi-Sideport Catheter Infusion Set | 5 | 0.035 | 65, 100, 130 | Manual administration of infusate | Intended to administer infusions of various therapeutic solutions and contrast media into the peripheral vasculature (refer to manufacturer's package insert for complete prescribing and dosing information) | |
| Surmodics, Inc. | Pounce LP Thrombectomy System | 7 | 0.018 | 150 | Comprised of three components: a delivery catheter, a basket wire, and a funnel catheter. The self-expanding nitinol baskets are delivered distal to the target lesion through the delivery catheter, after which the delivery catheter is withdrawn to deploy the baskets. After introducing the funnel catheter over the basket wire, the baskets are retracted to capture the clot into the funnel. With the clot entrained, the system is then locked and retracted into a minimum 7-F guide sheath to remove from the body | Intended for the nonsurgical removal of thrombi and emboli from the peripheral arterial vasculature; indicated for use in vessels ranging from 2 to 4 mm in diameter | |
| Surmodics, Inc. | Pounce Thrombectomy System | 7 | 0.035 | 135 | Comprised of three components: a delivery catheter, a basket wire, and a funnel catheter. The self-expanding nitinol baskets are delivered distal to the target lesion through the delivery catheter, after which the delivery catheter is withdrawn to deploy the baskets. After introducing the funnel catheter over the basket wire, the baskets are retracted to capture the clot into the funnel. With the clot entrained, the system is then locked and retracted into a minimum 7-F guide sheath to remove from the body | Intended for the nonsurgical removal of thrombi and emboli from the peripheral arterial vasculature; indicated for use in vessels ranging from 3.5 to 6 mm in diameter | |
| Surmodics, Inc. | Pounce Venous Thrombectomy System | 10 | 0.018 | 90 | Dual-action mechanical thrombectomy, using an adjustable mechanical basket and a rotational extraction screw to rapidly remove large quantities of fresh or organized, wall adherent clot from peripheral veins while allowing focal treatment of thrombosed vessels. No thrombolytics needed | Indicated for mechanical declotting and controlled and selective infusion of physician-specified fluids, including thrombolytics, in the peripheral vasculature. Designed for use in vessels ranging from 6 to 16 mm in diameter | |
| Surmodics, Inc. | Pounce XL Thrombectomy System | 7 | 0.035 | 135 | Comprised of three components: a delivery catheter, a basket wire, and a funnel catheter. The self-expanding nitinol baskets are delivered distal to the target lesion through the delivery catheter, after which the delivery catheter is withdrawn to deploy the baskets. After introducing the funnel catheter over the basket wire, the baskets are retracted to capture the clot into the funnel. With the clot entrained, the system is then locked and retracted into a minimum 7-F guide sheath to remove from the body | Intended for the nonsurgical removal of thrombi and emboli from the peripheral arterial vasculature; indicated for use in vessels ranging from 5.5 to 10 mm in diameter | |
| Imperative Care (Vascular) | Prodigy Thrombectomy System - Catheter | 5, 6, 8 | 0.014–0.035 | 50, 117, 137, 160 | Designed to remove thrombus from the peripheral vasculature using continuous aspiration; targets aspiration from the Vascular generator and through the Prodigy Hotshot controller and Prodigy catheter directly to the thrombus | Indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems; not for use in the coronaries, pulmonary vasculature, or the neurovasculature | |
| Imperative Care (Vascular) | Prodigy Thrombectomy System - HotShot Controller | – | – | – | Designed to remove thrombus from the peripheral vasculature using continuous aspiration; targets aspiration from the Vascular generator and through the Prodigy Hotshot controller and Prodigy catheter directly to the thrombus; the functional window on HotShot Controller is designed to inform the operator precisely when blood or clot moves through the system | Indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems; not for use in the coronaries, pulmonary vasculature, or the neurovasculature | |
| Imperative Care (Vascular) | Prodigy Thrombectomy System - Twist | – | – | 67, 134, 154, 177 | Prodigy Twist is a mechanical tool designed to clear corked clot from the catheter tip without cycling the catheter in-and-out of the body. It does this through dual-action clot engagement (rotation) and ingestion (retraction) | Indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems; not for use in the coronaries, pulmonary vasculature, or the neurovasculature | |
| Vesalio Inc. | pVasc Thrombectomy System 4.0 x 30 mm | Can be delivered through catheters with ID as small as 0.021 inch (1.6 F); also compatible with 0.035 inch (2.67 F) | 0.018 | Device basket working length: 30 mm; full length: 48 mm; pusher wire length: 200 cm | Delivered via a catheter (ID can be as small as .021", also compatible with .035"); deployed at the occlusion site, on or beyond the clot, the flow restoration zone re-establishes flow to distal territory and engages softer clots; drop zones capture all clots, including organized varieties; once thrombus integrated, the closed distal tip helps retain it during retrieval; pVasc can be used alone or with adjunctive therapy (compatible with coaspiration); work time is not limited by blood loss | Indicated for use in vessels ≥ 2 and ≤ 3.5 mm in diameter | |
| Vesalio Inc. | pVasc Thrombectomy System 4.0 x 38 mm | Can be delivered through catheters with ID as small as 0.021 inch (1.6 F); also compatible with 0.035 inch (2.67 F) | 0.018 | Device basket working length: 38 mm; full length: 55 mm; pusher wire length: 200 cm | Delivered via a catheter (ID can be as small as .021 inch, also compatible with .035 inch); deployed at the occlusion site, on or beyond the clot, the flow restoration zone re-establishes flow to distal territory and engages softer clots; drop zones capture all clots, including organized varieties; once thrombus is integrated, the closed distal tip helps retain it during retrieval; pVasc can be used alone or with adjunctive therapy (compatible with coaspiration); work time is not limited by blood loss | Indicated for use in vessels ≥ 2 and ≤ 3.5 mm in diameter | |
| Vesalio Inc. | pVasc Thrombectomy System 6.0 x 44 mm | Can be delivered through catheters with ID as small as 0.027 inch (2.06 F); also compatible with 0.035 inch (2.67 F) | 0.018 | Device basket working length: 44 mm; full length: 63 mm; pusher wire length: 200 cm | Delivered via a catheter (ID can be as small as .027", also compatible with .035"); deployed at the occlusion site, on or beyond the clot, the flow restoration zone re-establishes flow to distal territory and engages softer clots; drop zones capture all clots, including organized varieties; once thrombus integrated, the closed distal tip helps retain it during retrieval; pVasc can be used alone or with adjunctive therapy (compatible with coaspiration); work time is not limited by blood loss | Indicated for use in vessels ≥ 3.5 and ≤ 6 in diameter | |
| Philips | QuickClear mechanical thrombectomy system | 6, 8, 10 | 0.035 | 130, 85 | Sterile, all-in-one, single-use, aspiration catheter and battery-operated vacuum aspiration pump; 8-F and 10-F catheters are provided with an obturator that assists with the insertion of the catheter into the introducer sheath and aids the catheter to track over an 0.035-inch guidewire | Fresh, soft emboli and thrombi from the vessels of the peripheral arterial and venous systems (10 F venous only application) | |
| Boston Scientific Corporation | SmartClawThrombectomy Catheter | 8 | 0.035 | 145 | An expandable basket loosens and removes thrombus | Indicated for the nonsurgical removal of thrombi and emboli from the peripheral vasculature | |
| Imperative Care (Vascular) | Symphony Thrombectomy System - Catheter | 16, 24 | 0.035 | 82, 85, 117 | Designed to remove thrombus from the peripheral vasculature using powerful pulses of continuous aspiration | Indicated for the removal of fresh, soft emboli and thrombi in the peripheral vasculature and for the treatment of pulmonary embolism. The Symphony 16F 82 cm Thrombectomy System shares the same peripheral indications described herein; however, it is not for use in the pulmonary vasculature | |
| Imperative Care (Vascular) | Symphony Thrombectomy System - ProHelix Mechanical Assist | – | 0.035 | 102, 139 | Designed to engage and retrieve emboli and thrombi from the peripheral vasculature using continuous aspiration with the Symphony catheter | Indicated for the removal of fresh, soft emboli and thrombi in the peripheral vasculature and for the treatment of pulmonary embolism | |
| Inari Medical | Triever16 - FlowTriever Retrieval/Aspiration System | 20, 22, 24 | 0.035 | 107 | Mechanical and aspirational disruption, fragmentation, maceration, and retrieval of emboli and thrombi | The nonsurgical removal of emboli and thrombi from blood vessels, and injection, infusion and/or aspiration of contrast media and other fluids into or from a blood vessel; the FlowTriever System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism; Triever catheters are intended for use in treating clot in transit in the right atrium, but not in conjunction with FlowTriever catheters | |
| Inari Medical | Triever16 Curve - FlowTriever Retrieval/Aspiration System | 20, 22, 24 | 0.035 | 110 | Mechanical and aspirational disruption, fragmentation, maceration, and retrieval of emboli and thrombi | The nonsurgical removal of emboli and thrombi from blood vessels, and injection, infusion and/or aspiration of contrast media and other fluids into or from a blood vessel; the FlowTriever System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism; Triever catheters are intended for use in treating clot in transit in the right atrium, but not in conjunction with FlowTriever catheters | |
| Inari Medical | Triever20 - FlowTriever Retrieval/Aspiration System | 20, 22, 24 | 0.035 | 90 | Mechanical and aspirational disruption, fragmentation, maceration, and retrieval of emboli and thrombi | The nonsurgical removal of emboli and thrombi from blood vessels, and injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel; the FlowTriever System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism; Triever catheters are intended for use in treating clot in transit in the right atrium but not in conjunction with FlowTriever catheters | |
| Inari Medical | Triever20 Curve - FlowTriever Retrieval/Aspiration System | 20, 22, 24 | 0.035 | 105 | Mechanical and aspirational disruption, fragmentation, maceration, and retrieval of emboli and thrombi | The nonsurgical removal of emboli and thrombi from blood vessels, and injection, infusion and/or aspiration of contrast media and other fluids into or from a blood vessel; the FlowTriever System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism; Triever catheters are intended for use in treating clot in transit in the right atrium, but not in conjunction with FlowTriever catheters | |
| Inari Medical | Triever24 - FlowTriever Retrieval/Aspiration System | 24, 26 | 0.035 | 90 | Mechanical and aspirational disruption, fragmentation, maceration, and retrieval of emboli and thrombi | The nonsurgical removal of emboli and thrombi from blood vessels, and injection, infusion and/or aspiration of contrast media and other fluids into or from a blood vessel; the FlowTriever System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism; Triever Catheters are intended for use in treating clot in transit in the right atrium, but not in conjunction with FlowTriever catheters | |
| Liquet Medical Inc. | Versus Catheter | 8 | Primary catheter: 0.035; secondary catheter: 0.014 | Catheter length: 110; infusion zone: 12 | Employs dual lumens to facilitate hemodynamics-led thrombolysis; can be advanced over a guidewire or flow-directed balloon and provides real-time direct intracardiac and pulmonary artery pressure monitoring | The controlled and selective infusion of physician-specified fluids, including thrombolytics, into the pulmonary artery vasculature in adult patients; the assessment of a patient’s hemodynamic condition through direct intracardiac and pulmonary artery pressure monitoring |
Advertisement
Advertisement
We value keeping the Device Guide up to date.
If you want to add or update your company’s device listings, please let us know!
Contact UsOther Devices
More Categories:
Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View AllAdvertisement