6-, 12-, 18-, and 25-gauge tip loads for crossing chronic total occlusions
Bentley InnoMed GmbH (distributed by Cook Medical)
BeBack crossing catheter
4
0.018
80, 120
4 F (up and over 6 F)
A low-profile support catheter that has a crossing and targeted re-entry capability due to the steerable nitinol needle at the tip; a radiopaque marker indicates the direction in which the curved needle will protrude from the catheter’s tip; antegrade, retrograde, and crossover are possible for intraluminal and subintimal approach on 0.014- and 0.018-inch wire platform
Bentley InnoMed GmbH (distributed by Cook Medical)
BeBack crossing catheter
2.9
0.014
80, 120
2.9 F (up and over 5 F)
A low-profile support catheter that has a crossing and targeted re-entry capability due to the steerable nitinol needle at the tip; a radiopaque marker indicates the direction in which the curved needle will protrude from the catheter’s tip; antegrade, retrograde, and crossover are possible for intraluminal and subintimal approach on 0.014- and 0.018-inch wire platform
Recanalizes CTOs through ultrasonic mechanical vibration and cavitation; includes the GeoAlign Marketing System; compatible with Sidekick Support Catheter; available in OTW and RX configurations
Recanalizes CTOs through ultrasonic mechanical vibration and cavitation; includes the GeoAlign Marking System; compatible with Usher Support Catheter
Ra Medical Systems, Inc.
DABRA Catheter and Laser
5
–
150
0.070
Used with introducer, sheath, or guiding catheter; minimum vessel diameter: 1.8 mm
Cordis
Elitecross Support Catheter
4.5
0.035
82, 132
0.078
Extra support and angled crossing catheters provide support and pushability for a tailored approach to tough lesions; extra large lumen can accommodate 0.014-inch support catheter systems
Re-entry catheter designed with a unique flat balloon to self-orient in the subintimal space and easily target the true lumen using the Enteer Guidewire; catheter available in two sizes for above- and below-the-knee use
Specialized guidewire designed to target Enteer catheter exit ports and engage and penetrate tissue for re-entry into the true lumen from a subintimal position; available in three levels of stiffness (flexible, standard, stiff) for use across a range of peripheral vessels
Cordis
Frontrunner XP CTO Catheter
3.1
–
90, 140
0.039
Actuating distal tip creates a channel through occlusions via blunt microdissection
Avinger, Inc.
Kittycat 2
5
0.014
150
–
Peripheral OTW CTO crossing catheter; catheter shaft is preshaped for better steerability in the most tortuous anatomy; Juicebox compatible
Cordis
Micro Guide Catheter
4.5
–
82, 132
0.078
Support catheter for use with 90- or 140-cm Frontrunner XP CTO catheter
Avinger, Inc.
Ocelot
6
0.014
110
–
Peripheral OTW CTO crossing catheter with a fluted tip and onboard real-time OCT intravascular imaging for precise catheter navigation
Avinger, Inc.
Ocelot MVRX
6
0.014
110
–
Peripheral OTW CTO crossing catheter with a wedged tip and onboard real-time OCT intravascular imaging for precise catheter navigation
Avinger, Inc.
Ocelot PIXL
5
0.014
135
–
Peripheral OTW CTO crossing catheter with onboard real-time OCT intravascular imaging for precise catheter navigation and extra length for distal lesion access
Cordis
Outback Elite Re-Entry Catheter
5.9
0.014
80, 120
0.079
Enables re-entry of a guidewire from the subintimal space back into the true lumen via re-entry cannula and highly visible L and T markers
Peripheral re-entry catheter that utilizes IVUS guidance to precisely target re-entry into the true lumen
Baylis Medical Technologies
PowerWire Pro RF Guidewire
Can be used with any 0.035-inch compatible guide catheters
0.035
250
0.035
Designed to cross occluded peripheral stents with RF puncture technology; contact with metal terminates RF energy, reducing the potential for vessel extravasation when crossing in-stent occlusions; visualize the radiopaque tip within the stent under fluoroscopy; straight and angled-tip models available
Baylis Medical Technologies
PowerWire RF Guidewire
Can be used with any 0.035-inch compatible guide catheters
0.035
250
0.035
Nitinol core guidewire with PTFE coating and tapered distal end with active tip capable of delivering RF Puncture energy; radiopaque tip plus five markerbands with 1-cm spacing; straight and angled-tip models available
ThermopeutiX, Inc.
Primi Contrast-Sparing Support Catheter
2–3 distal tip (0.014–0.035-inch wire)
0.014–0.035
90–170
0.065–0.081
Shapeable tip, hydrophilic support catheter with ability to inject contrast and other agents locally without removing guidewire
Philips
Quick-Cross Extreme Support Catheter
4
0.014
135, 150
–
Low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, and pushability to track through complex anatomy
Philips
Quick-Cross Extreme Support Catheter
5
0.035
65, 90, 135, 150
–
Low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, and pushability to track through complex anatomy
Philips
Quick-Cross Extreme Support Catheter
4
0.018
90, 135, 150
–
Low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, and pushability to track through complex anatomy
Philips
Quick-Cross Select Support Catheter
5
0.035
65, 90, 135, 150
–
Angled and low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, pushability, and allows the ability to navigate through complex anatomy
Philips
Quick-Cross Select Support Catheter
4
0.018
90, 135, 150
–
Angled and low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, pushability, and allows the ability to navigate through complex anatomy
Philips
Quick-Cross Select Support Catheter
4
0.014
135, 150
–
Angled and low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, pushability, and allows the ability to navigate through complex anatomy
Philips
Quick-Cross Support Catheter
4
0.014
135, 150
–
Low-profile, hydrophilic-coated, tapered-tip catheter provides seamless catheter-to-guidewire transition to facilitate crossing of challenging lesions and tracking through tortuous anatomy
Philips
Quick-Cross Support Catheter
5
0.035
65, 90, 135, 150
–
Low-profile, hydrophilic-coated, tapered-tip catheter provides seamless catheter-to-guidewire transition to facilitate crossing of challenging lesions and tracking through tortuous anatomy
Philips
Quick-Cross Support Catheter
4
0.018
90, 135, 150
–
Low-profile, hydrophilic-coated, tapered-tip catheter provides seamless catheter-to-guidewire transition to facilitate crossing of challenging lesions and tracking through tortuous anatomy
ThermopeutiX, Inc.
Secondi Contrast-Sparing Support Catheter
2 distal tip
0.014–0.035
90–170
0.087–0.095
Shapeable tip, dual-wire hydrophilic support catheter with ability to inject contrast and other agents locally without removing guidewire
Merit Medical Systems, Inc.
Spinr High-Performance Guidewire Controller
–
0.014–0.038
–
0.014
Spinr is used to maneuver guidewires in the coronary and peripheral vasculature during interventional or diagnostic procedures; assists in accessing distal anatomy, navigating tortuous vessels, crossing old lesions, and working through fresh blockages
Medtronic
TrailBlazer Angled Support Catheter
2.3
0.014
90, 135, 150
0.055
A braided, low-profile hydrophilic catheter that provides optimized support for increased pushability in difficult to access and cross lesions
Medtronic
TrailBlazer Angled Support Catheter
4
0.035
65, 90, 135, 150
0.055
A braided, low-profile hydrophilic catheter that provides optimized support for increased pushability in difficult to access and cross lesions
Medtronic
TrailBlazer Angled Support Catheter
2.6
0.018
90, 135, 150
0.055
A braided, low-profile hydrophilic catheter that provides optimized support for increased pushability in difficult to access and cross lesions
Medtronic
TrailBlazer Support Catheter
4
0.018
90, 135, 150
0.045
A seamless, low-profile catheter that provides optimized support for increased pushability in difficult to cross lesions
Medtronic
TrailBlazer Support Catheter
4
0.014
135, 150
0.045
A seamless, low-profile catheter that provides optimized support for increased pushability in difficult to cross lesions
Medtronic
TrailBlazer Support Catheter
5
0.035
65, 90, 135, 150
0.066
A seamless, low-profile catheter that provides optimized support for increased pushability in difficult to cross lesions
Coaxial peripheral crossing set; both inner catheter and outer sheath are hydrophilically coated; inner catheter is braided with radiopaque tip; outer sheath is coil reinforced to provide exceptional tracking through tortuous anatomy; a tungsten-loaded tip on the outer sheath aids pushability and radiopacity; outer sheath is tapered down to inner catheter to provide additional support, strength, and pushability across challenging lesions
Low-profile peripheral CTO crossing catheter with atraumatic distal tip; device operates via physician-controlled torque handle for fast manual spinning; the spinning motion created by the torque device allows the catheter tip to find its way through the lesion; available in flexible and standard stiffness
Avinger, Inc.
Wildcat
6
0.035
110
–
Peripheral OTW CTO crossing catheter with six different modes of operation to cross any lesion; Juicebox compatible
Reflow Medical, Inc
Wingman14 CTO Crossing Catheter
2.7
0.014
65, 135, 150
0.039
A beveled tip catheter intended to be used in conjunction with steerable guidewires to access discrete regions of the peripheral vasculature; the Wingman Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable bevel tip) and activating handle
Reflow Medical, Inc
Wingman14C CTO Crossing Catheter
2.7
0.014
90, 135, 150
0.039
A beveled tip catheter intended to be used in conjunction with steerable guidewires to access discrete regions of the peripheral vasculature; the Wingman Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable bevel tip) and activating handle
Reflow Medical, Inc
Wingman18 CTO Crossing Catheter
3.8
0.018
90, 135, 150
0.052
A beveled tip catheter intended to be used in conjunction with steerable guidewires to access discrete regions of the peripheral vasculature; the Wingman Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable bevel tip) and activating handle
Reflow Medical, Inc
Wingman35 CTO Crossing Catheter
4.6
0.035
65, 90, 135
0.066
A beveled tip catheter intended to be used in conjunction with steerable guidewires to access discrete regions of the peripheral vasculature; the Wingman Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable bevel tip) and activating handle
Advertisement
Advertisement
We value keeping the Device Guide up to date.
If you want to add or update your company’s device listings, please let us know!