Aortic (AAA) / Main Body Grafts

View Chart
Company Name Product Name Main Body Diameter (mm) Main Body Length (cm) Main Body Delivery System Profile: Device OD (F) Sheath Required for Delivery Delivery Sheath OD (F) Fixation Location Stent Expansion Stent Material Graft Material Comments
Rhevera Medical AFX2 Endovascular AAA System 22, 25, 28 4, 6, 7, 8, 9, 10, 11, 12 (unibody main body lengths) 19 Yes; AFX introducer system (17-F ipsilateral, 7-F contralateral) 19 (ipsilateral), 9 (contralateral) Fixation at bifurcation, infrarenal, or suprarenal configurations for seal Self-expanding Cobalt chromium alloy DuraPly multilayer ePTFE –
Rhevera Medical Alto Abdominal Stent Graft System 20, 23, 26, 29, 34 8 15 No, integrated sheath Integrated 15-F OD sheath Suprarenal Adaptive sealing technology Nitinol PTFE With a 7-mm neck indication, the aortic main body seals using a patient-specific seal utilizing adaptive sealing technology

Advertisement

Advertisement

Aortic (AAA) / Iliac Limbs

View Chart
Company Name Product Name Iliac Limb Diameter (mm) Iliac Limb Length (cm) Comments
Rhevera Medical AFX2 Endovascular AAA System - Main Body Limbs 13, 16, 20 3, 4, 5.5 –
Rhevera Medical Alto Abdominal Stent Graft System - Ovation iX Iliac Limbs 10, 12, 14, 16, 18, 22, 28 8, 10, 12, 14, 16 –

Aortic (AAA) / Ancillary Components

View Chart
Company Name Product Name Main Body Extensions Diameter (mm) Main Body Extensions Length (cm) Iliac Leg Extensions Diameter (mm) Iliac Leg Extensions Length (cm) Aorto-Uni-Iliac/Converter Proximal Diameter (mm) Aorto-Uni-Iliac/Converter Length (cm) Occluders Diameter (mm) Comments
Rhevera Medical AFX2 Endovascular AAA System - Limb Extensions – – 20–13 (taper); 16, 20 (straight); 20–25 (stepped) 5.5, 6.5 (stepped); 5.5, 8.8 (straight); 7, 8.8 (taper) – – – –
Rhevera Medical AFX2 Endovascular AAA System - Vela Proximal Endograft System 25, 28, 34 (suprarenal/infrarenal) Suprarenal: 7.5, 8, 9.5, 10; infrarenal: 7.5, 8, 9.5, 10 – – – – – –
Rhevera Medical Alto Abdominal Stent Graft System - Ovation iX Iliac Limb Extensions – – 10, 12, 14, 16, 18, 22, 28 4.5 – – – –
Rhevera Medical Destino Twist Steerable Sheath – – – – – – – 55-cm usable length; 9-mm curve diameter; 6.5-F inner diameter

Sheaths / Special Access Sheaths

View Chart
Company Name Product Name Size (F) Length (cm) Guidewire Compatibility (inch) Curved or Straight Radiopaque Tip Type of Special Access
Rhevera Medical AFX Introducer System 17 45 0.035 Straight Yes Hydrophilic-coated sheath and dilator for AFX AAA graft

Other Devices / Mechanical Thrombectomy/Thrombolysis (Peripheral/Venous)

View Chart
Company Name Product Name Sheath Compatibility (F) Guidewire Compatibility (inch) Working Length (cm) Mode of Operation US FDA Indicated Use
Rhevera Medical Pounce LP Thrombectomy System 7 0.018 150 Comprised of three components: a delivery catheter, a basket wire, and a funnel catheter. The self-expanding nitinol baskets are delivered distal to the target lesion through the delivery catheter, after which the delivery catheter is withdrawn to deploy the baskets. After introducing the funnel catheter over the basket wire, the baskets are retracted to capture the clot into the funnel. With the clot entrained, the system is then locked and retracted into a minimum 7-F guide sheath to remove from the body Intended for the nonsurgical removal of thrombi and emboli from the peripheral arterial vasculature; indicated for use in vessels ranging from 2 to 4 mm in diameter
Rhevera Medical Pounce Thrombectomy System 7 0.035 135 Comprised of three components: a delivery catheter, a basket wire, and a funnel catheter. The self-expanding nitinol baskets are delivered distal to the target lesion through the delivery catheter, after which the delivery catheter is withdrawn to deploy the baskets. After introducing the funnel catheter over the basket wire, the baskets are retracted to capture the clot into the funnel. With the clot entrained, the system is then locked and retracted into a minimum 7-F guide sheath to remove from the body Intended for the nonsurgical removal of thrombi and emboli from the peripheral arterial vasculature; indicated for use in vessels ranging from 3.5 to 6 mm in diameter
Rhevera Medical Pounce XL Thrombectomy System 7 0.035 135 Comprised of three components: a delivery catheter, a basket wire, and a funnel catheter. The self-expanding nitinol baskets are delivered distal to the target lesion through the delivery catheter, after which the delivery catheter is withdrawn to deploy the baskets. After introducing the funnel catheter over the basket wire, the baskets are retracted to capture the clot into the funnel. With the clot entrained, the system is then locked and retracted into a minimum 7-F guide sheath to remove from the body Intended for the nonsurgical removal of thrombi and emboli from the peripheral arterial vasculature; indicated for use in vessels ranging from 5.5 to 10 mm in diameter

Other Devices / Percutaneous Transmural Arterial Bypass (SFA/Popliteal Treatment)

View Chart
Company Name Product Name Stent Graft Labeled Device Diameter (mm) Reference Vessel Diameter (mm) Available Device Nominal Lengths (mm) Re-Entry Device US FDA Indicated Use Comments
Rhevera Medical Detour System Torus* 6 5.6–6 100, 150, 200 Endocross† Long segment SFA (20–46 cm) *8-F compatible, 135-cm working length, ePTFE nitinol stent graft delivered over 0.035-inch wire; †8-F compatible sheath, 133-cm working length, dual 0.014-inch delivery with a 0.025-inch spring loaded 15-mm throw
Rhevera Medical Detour System Torus* 5.5 4.5–5.5 200 Endocross† Long segment SFA (20–46 cm) *8-F compatible, 135-cm working length, ePTFE nitinol stent graft delivered over 0.035-inch wire; †8-F compatible sheath, 133-cm working length, dual 0.014-inch delivery with a 0.025-inch spring loaded 15-mm throw
Rhevera Medical Detour System Torus* 6.7 6.1–6.7 100, 150, 200 Endocross† Long segment SFA (20–46 cm) *8-F compatible, 135-cm working length, ePTFE nitinol stent graft delivered over 0.035-inch wire; †8-F compatible sheath, 133-cm working length, dual 0.014-inch delivery with a 0.025-inch spring loaded 15-mm throw

More Categories:

Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View All

Advertisement

Latest News


October 15, 2026

SUCCESS PTA Evaluates Cordis Selution SLR DEB at 24 Months

October 15, 2026

Concept Medical’s MagicTouch Balloon Shows Low TLR and MALE Rates in Analysis From SirPAD Trial

October 14, 2026

Vantis Vascular’s 6-F CrossFast System Receives FDA Clearance 

Most Read Articles


Improving PAD Awareness, Access, and Amputation Prevention

With Eric A. Secemsky, MD, MSc, RPVI, FACC, FAHA, FSCAI, FSVM

The 2026 AHA/ACC Guideline for the Management of Acute Pulmonary Embolism

By Geoffrey D. Barnes, MD, MSc; Allison Burnett, PharmD; Jay Giri, MD, MPH; and Soophia Naydenov, MD

Expanding Neurovascular Applications of the Swift™ Coil System

With Mohsen Nouri, MD; Robert M. Starke, MD; Allison E. Strickland, MD; and Nitin Goyal, MD

Back to Top
Carotid Dialysis EVAR Embolization HTN Limb Salvage Neurointervention Oncology PE Radial Regulatory Renal SFA TEVAR Venous
Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Pulmonary Embolism Radial Regulatory Renal SFA TEVAR Venous

News• Current Issue• Archive• Device Guide• Advertising• About Calendar• Contact• Privacy• Submissions• Subscriptions


Endovascular Today (ISSN 1551-1944 print and ISSN 2689-792X online) is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field.



magazine Created with Sketch.

Free Print Subscriptions

Fill 1 Created with Sketch.

Email Newsletter



twitter-icon LinkedIn Created with Sketch. instagram BlueSky-Circle
Cardiac Interventions Today
Group 7 Copy 3 Created with Sketch.
bmc-secondary-mark-color copy Created with Sketch.

© 2026 Bryn Mawr Communications II, LLC.  
All Rights Reserved   •   Privacy Policy

one-trust-button