View Chart| Company Name | Product Name | Catheter Size (F) | Working Length (cm) | Minimum Guiding Catheter ID (inch) | Comments |
|---|---|---|---|---|---|
| Imperative Care (Stroke) | TracStar LDP Large Distal Platform | 8 | 95 | 0.088 | Designed for intracranial neurovascular access; single lumen, braid and coil reinforced, variable stiffness catheter with a radiopaque marker and a lubricious hydrophilic coating |
| Imperative Care (Stroke) | Zoom 88 Large Distal Platform | 8 | 110 | 0.088 | Stroke-specific neurovascular access catheter designed to get closer to clot; single lumen, braid and coil reinforced, variable stiffness catheters with a radiopaque marker and a lubricious hydrophilic coating |
| Imperative Care (Stroke) | Zoom 88 Support Large Distal Platform | 8 | 100 | 0.088 | Neurovascular access catheter with an engineered support profile designed to maintain the capability of 0.088-inch intracranial access with added stability; single lumen, braid and coil reinforced, variable stiffness catheter with a radiopaque marker and a lubricious hydrophilic coating |
| Imperative Care (Stroke) | Zoom RDL Radial Access System | 8 | 103 | 0.088 | Stroke-specific neurovascular platform cleared for intracranial access through the radial artery; the Zoom RDL Radial Access Catheter, with dilator, is a single lumen, braid and coil reinforced, variable stiffness catheter with a radiopaque marker and a lubricious hydrophilic coating |
| Imperative Care (Stroke) | Zoom 6F Insert Catheter, SIM | 6 | 143 | – | The first and only 6-F insert catheter portfolio with three shapes designed specifically for stroke patients |
| Imperative Care (Stroke) | Zoom 6F Insert Catheter, VRT | 6 | 137 | – | The first and only 6-F insert catheter portfolio with three shapes designed specifically for stroke patients |
| Imperative Care (Stroke) | Zoom 6F Insert Catheter, VTK | 6 | 140 | – | The first and only 6-F insert catheter portfolio with three shapes designed specifically for stroke patients |
Advertisement
Advertisement
Wires / Hydrophilic Guidewires
View Chart| Company Name | Product Name | Type | Diameter (inch) | Length (cm) | Tip Type | Comments |
|---|---|---|---|---|---|---|
| Imperative Care (Stroke) | Ikon 24 Guidewire | Stainless steel core and nitinol hypotube | 0.024 | 200 | Straight (shapeable) | Designed with a uniform 0.024-inch diameter and a progressive support profile |
Other Devices / Thrombus Aspiration Devices
View Chart| Company Name | Product Name | Type | Maximum Tip Diameter (mm) | Minimum Guide Catheter Size (F) | Catheter Length (cm) |
|---|---|---|---|---|---|
| Imperative Care (Stroke) | Zoom 35 Aspiration Catheter | Neurovascular aspiration catheter with asymmetric tip; single lumen, braid and coil reinforced, variable stiffness catheter with a radiopaque marker and a lubricious hydrophilic coating | Distal OD: 1.30 mm; ID: 0.035 inch | 6 | 160 |
| Imperative Care (Stroke) | Zoom 45 Aspiration Catheter | Neurovascular aspiration catheter with asymmetric tip; single lumen, braid and coil reinforced, variable stiffness catheter with a radiopaque marker and a lubricious hydrophilic coating | Distal OD: 1.52 mm; ID: 0.045 inch | 6 | 144 |
| Imperative Care (Stroke) | Zoom 55 Aspiration Catheter | Neurovascular aspiration catheter with asymmetric tip; single lumen, braid and coil reinforced, variable stiffness catheter with a radiopaque marker and a lubricious hydrophilic coating | Distal OD: 1.75 mm; ID: 0.055 inch | 6 | 137 |
| Imperative Care (Stroke) | Zoom 71 Aspiration Catheter | Neurovascular aspiration catheter with asymmetric tip; single lumen, braid and coil reinforced, variable stiffness catheter with a radiopaque marker and a lubricious hydrophilic coating | Distal OD: 2.11 mm; ID: 0.071 inch | 6 | 137 |
| Imperative Care (Stroke) | Zoom 7X Aspiration Catheter | Neurovascular aspiration catheter with asymmetric tip and CenTRX technology; single lumen, braid and coil reinforced, variable stiffness catheter with a radiopaque marker and a lubricious hydrophilic coating | Distal OD: 2.11 mm, ID: 0.071 inch | 6 | 137 |
| Imperative Care (Stroke) | Zoom 4S Aspiration Catheter | Neurovascular aspiration catheter with asymmetric tip; single lumen, braid and coil reinforced, variable stiffness catheter with a radiopaque marker and a lubricious hydrophilic coating | Distal OD: 1.4 mm; ID: 0.045 inch | 6 | 125, 144, 160 |
Other Devices / Mechanical Thrombectomy (Neurovascular)
View Chart| Company Name | Product Name | Sheath Compatibility (F) | Guidewire Compatibility (inch) | Working Length (cm) | Mode of Operation | US FDA Indicated Use |
|---|---|---|---|---|---|---|
| Imperative Care (Stroke) | Zoom Aspiration Catheters: Zoom 7X, Zoom 71, Zoom 55, Zoom 45, Zoom 4S, Zoom 35 | – | – | 137–160 | Vessel-matched aspiration catheters with asymmetric tip; designed to be used as a complete system with the Zoom 88 Large Distal Platform, Zoom POD, Zoom DuoPort and Imperative Care Pump | The Zoom System consists of the following devices: (7X, 71, 55, 45, 4S, 35) Catheters, Zoom 88 Large Distal Platform (Zoom 88), Zoom 88 Large Distal Platform Support (Zoom 88 Support), TracStar LDP Large Distal Platform (TracStar LDP), Zoom Aspiration Tubing or Zoom POD Aspiration Tubing when used with the Zoom Aspiration Pump (or equivalent vacuum pump) with Zoom Canister or Zoom DuoPort Canister; the Zoom System, when used with the Zoom Aspiration Pump (or equivalent vacuum pump), is indicated for use in the revascularization of patients with acute ischemic stroke secondary to intracranial large vessel occlusive disease (within the internal carotid, middle cerebral – M1 and M2 segments, basilar, and vertebral arteries) within 8 hours of last known well; patients who are ineligible for intravenous thrombolytic drug therapy or who have not responded to thrombolytic drug therapy are candidates for treatment; the Zoom Aspiration Pump is intended for general suction use in hospitals and clinics; the Zoom Aspiration Tubing and the Zoom POD Aspiration Tubing are intended to connect to the Zoom (7X, 71, 55, 45, 4S, 35) Catheter, Zoom 88, Zoom 88 Support, TracStar LDP to the Zoom Canister of the Zoom Aspiration Pump (or equivalent vacuum pump) and to allow the user to control the fluid flow; the Zoom (7X, 71, 55, 45, 4S, 35) Catheters, Zoom 88, Zoom 88 Support, TracStar LDP should only be used by physicians who have received appropriate training in interventional techniques and treatment of acute ischemic stroke |
| Imperative Care (Stroke) | Zoom 6F Insert Catheters - Zoom VTK, Zoom VRT, Zoom SIM | – | – | 137–143 | The first and only 6-F Insert Catheter Portfolio with three shapes designed specifically for stroke patients | The Zoom 6F Insert Catheters are indicated for use in delivering radiopaque media to selected sites in the peripheral vascular system in conjunction with routine diagnostic procedures |