Advertisement
Advertisement
Specialty Catheters
74 products
All Columns
| Compare | Company Name | Product Name | Catheter Size (F) | Working Length (cm) | Minimum Guiding Catheter ID (inch) | Comments |
|---|---|---|---|---|---|---|
| Asahi Intecc USA, Inc. | Asahi Corsair Armet | 2.5 | 60, 90, 135, 150 | 0.017 | Stainless steel braided catheter with increased support and a durable metal tip for use in the peripheral vasculature | |
| Asahi Intecc USA, Inc. | Asahi Fubuki 4.2-F Distal Support System | 4.2 (ID: 0.043 inch) | 120, 125, 130 | 6 F | Suitable for triaxial system | |
| Bentley InnoMed GmbH (distributed by Cook Medical) | BeBack crossing catheter | 4 | 80, 120 | 4 F–0.018 inch (up and over 6 F) | A low-profile support catheter that has a crossing and targeted re-entry capability due to the steerable nitinol needle at the tip; a radiopaque marker indicates the direction in which the curved needle will protrude from the catheter’s tip; antegrade, retrograde, and crossover are possible for intraluminal and subintimal approach on 0.014- and 0.018-inch wire platform | |
| Bentley InnoMed GmbH (distributed by Cook Medical) | BeBack crossing catheter | 2.9 | 80, 120 | 2.9 F–0.014 inch (up and over 5 F) | A low-profile support catheter that has a crossing and targeted re-entry capability due to the steerable nitinol needle at the tip; a radiopaque marker indicates the direction in which the curved needle will protrude from the catheter’s tip; antegrade, retrograde, and crossover are possible for intraluminal and subintimal approach on 0.014- and 0.018-inch wire platform | |
| Cerenovus | Cerenovus Large Bore Catheter (0.071-inch ID) | OD: 0.081 inch (distal), 0.0825-inch (proximal) | 115, 125, 132 | – | – | |
| Cook Medical | CrossCath Support Catheter | Distal: 1.5, 1.8, 3.1; proximal: 3, 3.4, 4.8 | 65, 90, 135, 150 | 0.041, 0.046, 0.065 | Tapered, hydrophilic-coated support catheter; single lumen; radiopaque markers | |
| Cook Medical | CXI Support Catheter | 2.6 (0.018-inch wire) | 65, 90, 135, 150 | 0.032 | Flexible, braided catheter shaft with hydrophilic coating tracks through complex anatomy and provides support for crossing difficult lesions; radiopaque markers and tip assist with placement and sizing | |
| Cook Medical | CXI Support Catheter | 2.3 (0.014-inch wire) | 65, 90, 135, 150 | 0.015 | Flexible, braided catheter shaft with hydrophilic coating tracks through complex anatomy and provides support for crossing difficult lesions; radiopaque marker bands assist with placement and sizing | |
| Cook Medical | CXI Support Catheter | 4 (0.035-inch wire) | 90, 135, 150 | 0.052 | Flexible, braided catheter shaft with hydrophilic coating tracks through complex anatomy and provides support for crossing difficult lesions; radiopaque markers and tip assist with placement and sizing | |
| Prytime Medical Devices, Inc. | ER-REBOA PLUS Catheter | 7 | 72 | – | The ER-REBOA PLUS catheter is a large vessel occlusion catheter; the device consists of an atraumatic distal tip (P-tip), a compliant occlusion balloon, and a catheter shaft with a built-in central lumen for blood pressure monitoring | |
| VentureMed Group, Inc. | Flex Vessel Prep System | 6 | 40 | 0.092 | Flex creates precise, controlled-depth microincisions along the entire length of the lesion/stenoses, releasing the circumferential tension to improve compliance and luminal gain at lower balloon pressures for less vessel trauma and complications; intended for use with PTA catheters to facilitate dilation of stenoses in the femoral and popliteal arteries and treatment of obstructive lesions of native or synthetic AV dialysis fistulas; also indicated for ISR | |
| VentureMed Group, Inc. | Flex Vessel Prep System | 6 | 120 | 0.092 | Flex creates precise, controlled-depth microincisions along the entire length of the lesion/stenoses, releasing the circumferential tension to improve compliance and luminal gain at lower balloon pressures for less vessel trauma and complications; intended for use with PTA catheters to facilitate dilation of stenoses in the femoral and popliteal arteries and treatment of obstructive lesions of native or synthetic AV dialysis fistulas; also indicated for ISR | |
| Gore & Associates | Gore Tri-Lumen Catheter | 12 | 140 | 0.035 | Multi-lumen catheter comprised of a central lumen and two auxiliary lumens | |
| Teleflex | GuideLiner V3 Catheter | 5, 5.5, 6, 7, 8 | 150 | ≥ 0.056 (5 F), ≥ 0.066, ≥ 0.070 (6 F), ≥ 0.078 (7 F), ≥ 0.088 (8 F) | Features a half-pipe design for seamless collar transition; this rapid-exchange, coaxial mother-and-child guide extension is delivered through standard guide catheters, resulting in an ID approximately one F size smaller than the guide catheter; used to access discrete regions of the coronary and/or peripheral vasculature and to facilitate placement of interventional devices | |
| Teleflex | GuideLiner XL Catheter | 6 | 150 | ≥ 0.070 (6 F) | Extra long guide extension that maintains collar transition in less tortuous anatomy while allowing up to 15 cm of extension out of the guide catheter | |
| F Care Systems | Kavs | 9 | 100 | 0.025 | A catheter for assisted venous sclerotherapy to treat GSV; it is equipped with a balloon to block the vein; three lumens: one for guidewire, one for balloon, one for injection | |
| Teleflex | Minnie Support Catheter 0.014 | Distal: 2; proximal: 3.1 | 135, 150 | ≥ 0.056 (5 F) | Hydrophilic coated; its smoothly tapered distal tip combined with a low crossing profile and fully embedded radiopaque markers are intended to provide guidewire support and exchange or delivery of therapeutic agents | |
| Teleflex | Minnie Support Catheter 0.018 | Distal: 2.3; proximal: 3.4 | 90, 135, 150 | ≥ 0.070 (6 F) | Hydrophilic coated; its smoothly tapered distal tip combined with a low crossing profile and fully embedded radiopaque markers are intended to provide guidewire support and exchange or delivery of therapeutic agents | |
| Teleflex | Minnie Support Catheter 0.035 | Distal: 3.8; proximal: 4.8 | 65, 90, 135, 150 | ≥ 0.070 (6 F) | Hydrophilic coated; its smoothly tapered distal tip combined with a low crossing profile and fully embedded radiopaque markers are intended to provide guidewire support and exchange or delivery of therapeutic agents | |
| BioCardia, Inc. | Morph Deflectable Tip Guide Catheter | 8 | 110 | 0.038 | Universal steerable guiding catheter with reinforced braided shaft and distal soft tip | |
| Terumo Interventional Systems | NaviCross Support Catheter | 2.6 (0.018-inch wire), 4 (0.035-inch wire) | 65, 90, 135, 150 | 0.034 (2.6F), 0.052 (4F) | Double-braided wire support catheter with tapered tip, three radiopaque markers, and Terumo Glide Technology hydrophilic coating | |
| ThermopeutiX, Inc. | Primi Contrast-Sparing Support Catheter | 2–3 distal tip (0.014–0.035 inch wire) | 90–170 | 5–6 F (sheath) | Hydrophilic support catheter with ability to inject contrast and other agents locally without removing guidewire | |
| Philips | Quick-Cross Extreme Support Catheter | 4 | 90, 135, 150 | 5 F (guide)/4 F (sheath) | Low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, and pushability to track through complex anatomy | |
| Philips | Quick-Cross Extreme Support Catheter | 5 | 65, 90, 135, 150 | 5 F (sheath) | Low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, and pushability to track through complex anatomy | |
| Philips | Quick-Cross Extreme Support Catheter | 4 | 135, 150 | 5 F (guide)/4 F (sheath) | Low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, and pushability to track through complex anatomy | |
| Philips | Quick-Cross Select Support Catheter | 4 | 90, 135, 150 | 5 F (guide)/4 F (sheath) | Angled and low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, and pushability and allows the ability to navigate through complex anatomy | |
| Philips | Quick-Cross Select Support Catheter | 4 | 135, 150 | 5 F (guide)/4 F (sheath) | Angled and low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, and pushability and allows the ability to navigate through complex anatomy | |
| Philips | Quick-Cross Select Support Catheter | 5 | 65, 90, 135, 150 | 5 F (sheath) | Angled and low-profile tip, hydrophilic coating, and stainless steel braid provide increased strength, torque, and pushability and allows the ability to navigate through complex anatomy | |
| Philips | Quick-Cross Support Catheter | 5 | 65, 90, 135, 150 | 6 F (guide)/5 F (sheath) | Low-profile, hydrophilic-coated, tapered-tip catheter provides seamless catheter-to-guidewire transition to facilitate crossing of challenging lesions and tracking through tortuous anatomy | |
| Philips | Quick-Cross Support Catheter | 4 | 135, 150 | 5 F (guide)/4 F (sheath) | Low-profile, hydrophilic-coated, tapered-tip catheter provides seamless catheter-to-guidewire transition to facilitate crossing of challenging lesions and tracking through tortuous anatomy | |
| Philips | Quick-Cross Support Catheter | 4 | 90, 135, 150 | 5 F (guide)/4 F (sheath) | Low-profile, hydrophilic-coated, tapered-tip catheter provides seamless catheter-to-guidewire transition to facilitate crossing of challenging lesions and tracking through tortuous anatomy | |
| Terumo Interventional Systems | R2P NaviCross Support Catheter | 4.5 (0.035-inch wire) | 200 | 0.059 (4.5 F) | Double-braided wire support catheter with tapered tip, three radiopaque markers, and Terumo Glide Technology hydrophilic coating | |
| Balt USA | Raptor 071 Aspiration Catheter | 6 | 128, 132 | 0.071 | – | |
| Balt USA | Raptor 074 Aspiration Catheter | 6.6 | 120, 132 | 0.074 | – | |
| Boston Scientific Corporation | Rubicon Control Support Catheter | Rubicon 0.014, 0.018 (4 F); Rubicon 0.035 (5 F); distal tip profile: Rubicon Control 0.014 (40° distal tip); Rubicon Control 0.018 (40°, straight distal tip): Rubicon Control 0.035 (45°, 20°, straight distal tip) | 65, 90, 135, 150 | 0.014, 0.018, 0.035 | Intended to facilitate placement and support of guidewires and other interventional devices within the peripheral vasculature for complex anatomy | |
| Boston Scientific Corporation | Rubicon Support Catheter | 4 (0.014, 0.018 inch), 5 (0.035 inch); distal tip profile: 0.014 (0.018-inch distal tip profile), 0.018 (0.022-inch distal tip profile), 0.035 (0.037-inch distal tip profile) | 65, 90, 135, 150 | 0.014, 0.018, 0.035 | Intended to facilitate placement and support of guidewires and other interventional devices within the peripheral vasculature and to allow for exchange of guidewires and provide a conduit for the delivery of saline or contrast solutions | |
| ThermopeutiX, Inc. | Secondi Contrast-Sparing Support Catheter | 2–3 distal tip (0.014–0.035 inch wire) | 90–170 | 6–8 F (sheath) | Dual-guidewire hydrophilic support catheter with ability to inject contrast and other agents locally without removing guidewire; particularly useful in CTO, bifurcations, and other complex anatomy | |
| BD Interventional | Seeker Crossing Support Catheter | 4, 5 | 65, 90, 135, 150 | 4, 5 F | Hydrophilic-coated support catheter with a 30-cm radiopaque marking system, sized to support standard 0.014-, 0.018-, and 0.035-inch guidewires | |
| Terumo Neuro | SOFIA | 5 | 115, 125 | 0.070 | Designed for distal navigation and supports precise delivery of a variety of neurovascular therapies | |
| Terumo Neuro | SOFIA | 6 | 115 | 0.085 | Designed for distal navigation and supports precise delivery of a variety of neurovascular therapies | |
| Reflow Medical, Inc | Spex35 Shapeable Support Microcatheter | 4.6 | 50, 90, 135, 150 | 0.066 | Single lumen, shapeable tip support catheter designed to access the peripheral vasculature; allows for exchange of guidewires and other interventional devices and provides a conduit for delivery of saline solutions or diagnostic contrast; available in a variety of lengths; braided support matrix and hydrophlilic coating (distal segment); the distal tip of the Spex has one radiopaque marker | |
| Reflow Medical, Inc | SpexLP 14 Shapeable Support Microcatheter | 2.2 | 90, 135, 150 | 0.052 | Single lumen, shapeable tip support catheter designed to access the peripheral vasculature; allows for exchange of guidewires and other interventional devices and provides a conduit for delivery of saline solutions or diagnostic contrast; available in a variety of lengths and diameters; braided support matrix and hydrophilic coating (distal segment); Spex LP has 3 radiopaque markers spaced equally along the distal shaft at 50-mm increments, to aid in estimating geometry within the vascular system | |
| Reflow Medical, Inc | SpexLP 18 Shapeable Support Microcatheter | 2.5 | 90, 135, 150 | 0.052 | Single lumen, shapeable tip support catheter designed to access the peripheral vasculature; allows for exchange of guidewires and other interventional devices and provides a conduit for delivery of saline solutions or diagnostic contrast; available in a variety of lengths and diameters; braided support matrix and hydrophilic coating (distal segment); Spex LP has 3 radiopaque markers spaced equally along the distal shaft at 50-mm increments, to aid in estimating geometry within the vascular system | |
| Reflow Medical, Inc | SpexLP 35 Shapeable Support Microcatheter | 3.8 | 90, 135, 150 | 0.052 | Single lumen, shapeable tip support catheter designed to access the peripheral vasculature; allows for exchange of guidewires and other interventional devices and provides a conduit for delivery of saline solutions or diagnostic contrast; available in a variety of lengths and diameters; braided support matrix and hydrophilic coating (distal segment); Spex LP has 3 radiopaque markers spaced equally along the distal shaft at 50-mm increments, to aid in estimating geometry within the vascular system | |
| Teleflex | SuperCross Microcatheter OTW - 0.014 Angled Tips: 45°, 90°, 120°, and 90° Extended Tip | Distal: 2.4; proximal: 3.2 | 130, 150 | 0.014 | Low-profile, hydrophilic-coated, OTW microcatheter is available in multiple tip angle options (45°, 90°, 120°, and 90° extended tip) with dual coil design for good torque response and delivery into branched anatomy | |
| Teleflex | SuperCross Microcatheter OTW - 0.014 Straight and Flexible Tip | Distal: 1.8; proximal: 2.5 | 130, 150 | 0.014 | Low-profile, hydrophilic-coated, braided OTW microcatheter with straight tip and flexible tip options provides support when navigating tortuous anatomy and bifurcated vessels | |
| Merit Medical Systems, Inc. | SureCross Support Catheter - 0.014 inch | 1.5 crossing profile (0.020 inch) | 65, 90, 135, 150 | 0.066 (5 F) | Low-profile, hydrophilic-coated, tapered-tip catheter provides seamless catheter-to-guidewire transition to facilitate crossing of challenging lesions and tracking through tortuous anatomy | |
| Merit Medical Systems, Inc. | SureCross Support Catheter - 0.018 inch | 1.7 crossing profile (0.022 inch) | 65, 90, 135, 150 | 0.066 (5 F) | Low-profile, hydrophilic-coated, tapered-tip catheter provides seamless catheter-to-guidewire transition to facilitate crossing of challenging lesions and tracking through tortuous anatomy | |
| Merit Medical Systems, Inc. | SureCross Support Catheter - 0.035 inch | 3.1 crossing profile (0.040 inch) | 65, 90, 135, 150 | 0.079 (6 F) | Low-profile, hydrophilic-coated, tapered-tip catheter provides seamless catheter-to-guidewire transition to facilitate crossing of challenging lesions and tracking through tortuous anatomy | |
| ThermopeutiX, Inc. | TAPAS Targeted Drug Delivery System | Minimum vessel size: 1.8 mm | 175 | 7 F (sheath) | Targeted delivery of physician-specified drugs; adjustable treatment zone up to 300 mm; able to aspirate out drug after use; multiple use in a single patient | |
| Asahi Intecc USA, Inc. | Tornus Specialty Catheter | 2.1, 2.6 | 135 | – | The specialty catheter, with its threaded stainless steel construction, enables the exchange and support required for treating chronically stenosed lesions | |
| Imperative Care (Stroke) | TracStar LDP Large Distal Platform | 8 | 95 | 0.088 | Designed for intracranial neurovascular access; single lumen, braid and coil reinforced, variable stiffness catheter with a radiopaque marker and a lubricious hydrophilic coating | |
| Medtronic | TrailBlazer Angled Support Catheter | 2.3 (0.014-inch wire) | 90, 135, 150 | 0.055 | A braided, low-profile hydrophilic catheter that provides optimized support for increased pushability in difficult-to-access and -cross lesions | |
| Medtronic | TrailBlazer Angled Support Catheter | 4 (0.035-inch wire) | 65, 90, 135, 150 | 0.055 | A braided, low-profile hydrophilic catheter that provides optimized support for increased pushability in difficult-to-access and -cross lesions | |
| Medtronic | TrailBlazer Angled Support Catheter | 2.6 (0.018-inch wire) | 90, 135, 150 | 0.055 | A braided, low-profile hydrophilic catheter that provides optimized support for increased pushability in difficult-to-access and -cross lesions | |
| Medtronic | TrailBlazer Support Catheter | 5 (0.035-inch wire) | 65, 90, 135, 150 | 0.066 | A seamless, low-profile hydrophilic catheter that provides optimized support for increased pushability in difficult-to-cross lesions | |
| Medtronic | TrailBlazer Support Catheter | 4 (0.014-inch wire) | 135, 150 | 0.045 | A seamless, low-profile hydrophilic catheter that provides optimized support for increased pushability in difficult-to-cross lesions | |
| Medtronic | TrailBlazer Support Catheter | 4 (0.018-inch wire) | 90, 135, 150 | 0.045 | A seamless, low-profile hydrophilic catheter that provides optimized support for increased pushability in difficult-to-cross lesions | |
| Cook Medical | TriForce Peripheral Crossing Set | Inner catheter: 4, outer sheath: 5, tapering to 4 (0.035-inch wire) | 65, 100 | 0.052 | Coaxial peripheral crossing set; both inner catheter and outer sheath are hydrophilically coated; inner catheter is braided with radiopaque tip; outer sheath is coil-reinforced to provide exceptional tracking through tortuous anatomy; a tungsten-loaded tip on the outer sheath aids pushability and radiopacity; outer sheath is tapered down to inner catheter to provide additional support, strength, and pushability across challenging lesions | |
| Teleflex | Twin-Pass Dual Access Catheter | 3.5 | 135 | ≥ 0.066 (≥ 6 F) | Dual-lumen catheter with two independent 0.014-inch lumens; for guidewire access, guidewire support, and/or the delivery of contrast or medication | |
| Abbott | ViperCath XC Peripheral Exchange Catheter | 5 | 200 | 0.054 | Straight or 30° angled options | |
| Abbott | ViperCross Support Catheter (0.014) | 4 | 135, 150 | 0.017 | Variable-pitch stainless-steel braid design with low profile and hydrophilic coating, this portfolio of catheters offers proximal support and distal flexibility for crossing challenging lesions; radiopaque markerbands for visibility at 1 mm, 5 cm, and 10 cm; available in straight tips | |
| Abbott | ViperCross Support Catheter (0.018) | 4 | 65, 90, 135, 150 | 0.0215 | Variable-pitch stainless-steel braid design with low profile and hydrophilic coating, this portfolio of catheters offers proximal support and distal flexibility for crossing challenging lesions; radiopaque markerbands for visibility at 1 mm, 5 cm, and 10 cm; available in straight tips | |
| Abbott | ViperCross Support Catheter (0.035) | 5 | 65, 90, 135, 150 | 0.041 | Variable-pitch stainless-steel braid design with low profile and hydrophilic coating, this portfolio of catheters offers proximal support and distal flexibility for crossing challenging lesions; radiopaque markerbands for visibility at 1 mm, 5 cm, and 10 cm; available in straight and angled tips | |
| Reflow Medical, Inc | Wingman14 CTO Crossing Catheter | 2.7 | 65, 135, 150 | 0.039 | A beveled tip catheter intended to be used in conjunction with steerable guidewires to access discrete regions of the peripheral vasculature; the Wingman Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable bevel tip) and activating handle | |
| Reflow Medical, Inc | Wingman14C CTO Crossing Catheter | 2.7 | 90, 135, 150 | 0.039 | A beveled tip catheter intended to be used in conjunction with steerable guidewires to access discrete regions of the peripheral vasculature; the Wingman Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable bevel tip) and activating handle | |
| Reflow Medical, Inc | Wingman18 CTO Crossing Catheter | 3.8 | 90, 135, 150 | 0.052 | A beveled tip catheter intended to be used in conjunction with steerable guidewires to access discrete regions of the peripheral vasculature; the Wingman Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable bevel tip) and activating handle | |
| Reflow Medical, Inc | Wingman35 CTO Crossing Catheter | 4.6 | 65, 90, 135 | 0.066 | A beveled tip catheter intended to be used in conjunction with steerable guidewires to access discrete regions of the peripheral vasculature; the Wingman Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable bevel tip) and activating handle | |
| Imperative Care (Stroke) | Zoom 6F Insert Catheter, SIM | 6 | 143 | – | The first and only 6-F insert catheter portfolio with three shapes designed specifically for stroke patients | |
| Imperative Care (Stroke) | Zoom 6F Insert Catheter, VRT | 6 | 137 | – | The first and only 6-F insert catheter portfolio with three shapes designed specifically for stroke patients | |
| Imperative Care (Stroke) | Zoom 6F Insert Catheter, VTK | 6 | 140 | – | The first and only 6-F insert catheter portfolio with three shapes designed specifically for stroke patients | |
| Imperative Care (Stroke) | Zoom 88 Large Distal Platform | 8 | 110 | 0.088 | Stroke-specific neurovascular access catheter designed to get closer to clot; single lumen, braid and coil reinforced, variable stiffness catheters with a radiopaque marker and a lubricious hydrophilic coating | |
| Imperative Care (Stroke) | Zoom 88 Support Large Distal Platform | 8 | 100 | 0.088 | Neurovascular access catheter with an engineered support profile designed to maintain the capability of 0.088-inch intracranial access with added stability; single lumen, braid and coil reinforced, variable stiffness catheter with a radiopaque marker and a lubricious hydrophilic coating | |
| Imperative Care (Stroke) | Zoom RDL Radial Access System | 8 | 103 | 0.088 | Stroke-specific neurovascular platform cleared for intracranial access through the radial artery; the Zoom RDL Radial Access Catheter, with dilator, is a single lumen, braid and coil reinforced, variable stiffness catheter with a radiopaque marker and a lubricious hydrophilic coating |
Advertisement
Advertisement
We value keeping the Device Guide up to date.
If you want to add or update your company’s device listings, please let us know!
Contact UsCatheters
More Categories:
Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View AllAdvertisement