Group 7 Copy 3 Created with Sketch.
News Issue Archive Device Guide Calendar Subscribe Advertising

MENU

Centers

Carotid Dialysis EVAR Embolization HTN Limb Salvage Neurointervention Oncology PE Radial Regulatory Renal SFA TEVAR Venous

News Current Issue Archive Device Guide Calendar Subscribe Advertising About Contact Privacy Submissions
Carotid Dialysis EVAR Embolization HTN Limb Salvage Neurointervention Oncology PE Radial Regulatory Renal SFA TEVAR Venous

Back to Top

Advertisement

Advertisement

US Company Directory


Rex Medical

555 North Lane, Suite 5035, Conshohocken, PA 19428

PHONE: (610) 940-0665 | FAX: (610) 940-1590

down-arrow Created with Sketch.
down-arrow Created with Sketch.

Balloons / PTA Balloons

View Chart
Company Name Product Name Nominal Pressure (atm) Rated Burst Pressure (atm) Guidewire Compatibility (inch) Shaft Length (cm) Sheath Compatibility (F) Balloon Diameters (mm) Balloon Lengths (cm)
Rex Medical SplitWire PTA Scoring Technology – Dependent on rated burst pressure of balloon used 0.014, 0.018, 0.035 100, 200, 300 Dependent on the introducer compatibility of the balloon used Unlimited Compatible with balloon lengths of 20–300 mm

Advertisement

Advertisement

Other Devices / Atherectomy Devices

View Chart
Company Name Product Name Minimum Vessel Diameter (mm) Sheath Compatibility (F) Crossing Profile (inch) Working Length (cm) Tip Length (cm)
Rex Medical Revolution Peripheral Atherectomy System 1.33 mm (4F, 60cm length) 2 4 0.052 (1.33 mm) 60 0.47
Rex Medical Revolution Peripheral Atherectomy System 1.33 mm (6F, 145cm length) 2 6 0.052 (1.33 mm) 145 0.47
Rex Medical Revolution Peripheral Atherectomy System 1.33 mm (6F, 200cm length) 2 6 0.052 (1.33 mm) 200 0.47
Rex Medical Revolution Peripheral Atherectomy System 1.66 mm (6F, 145cm length) 2.5 6 0.065 (1.66 mm) 145 0.47
Rex Medical Revolution Peripheral Atherectomy System 1.66 mm (6F, 200cm length) 2.5 6 0.065 (1.66 mm) 200 0.47
Rex Medical Revolution Peripheral Atherectomy System 2 mm (6F, 145cm length) 3 6 0.078 (2 mm) 145 0.47
Rex Medical Revolution Peripheral Atherectomy System 2 mm (6F, 200cm length) 3 6 0.078 (2 mm) 200 0.47
Rex Medical Revolution Peripheral Atherectomy System 2.33 mm (7F, 145cm length) 3 7 0.091 (2.33 mm) 145 0.47

More Categories:

Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View All

Advertisement

Latest News


November 19, 2026

Rhevera Marks Milestones With the Detour System for Complex PAD

November 17, 2026

Perfuze’s NeuroSheath 8-F Long Sheath Receives FDA Clearance

November 17, 2026

Radical’s Reperfusion Catheters Cleared for AIS

Most Read Articles


Improving PAD Awareness, Access, and Amputation Prevention

With Eric A. Secemsky, MD, MSc, RPVI, FACC, FAHA, FSCAI, FSVM

The 2026 AHA/ACC Guideline for the Management of Acute Pulmonary Embolism

By Geoffrey D. Barnes, MD, MSc; Allison Burnett, PharmD; Jay Giri, MD, MPH; and Soophia Naydenov, MD

Three Keys to Creating and Maturing pAVFs for Successful Cannulation Safety

By Rishi Razdan, MD

Back to Top
Carotid Dialysis EVAR Embolization HTN Limb Salvage Neurointervention Oncology PE Radial Regulatory Renal SFA TEVAR Venous
Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Pulmonary Embolism Radial Regulatory Renal SFA TEVAR Venous

News• Current Issue• Archive• Device Guide• Advertising• About Calendar• Contact• Privacy• Submissions• Subscriptions


Endovascular Today (ISSN 1551-1944 print and ISSN 2689-792X online) is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field.



magazine Created with Sketch.

Free Print Subscriptions

Fill 1 Created with Sketch.

Email Newsletter



twitter-icon LinkedIn Created with Sketch. instagram BlueSky-Circle
Cardiac Interventions Today
Group 7 Copy 3 Created with Sketch.
bmc-secondary-mark-color copy Created with Sketch.

© 2026 Bryn Mawr Communications II, LLC.  
All Rights Reserved   •   Privacy Policy

one-trust-button