PowerCross PTA Balloon
Dilatation Catheter
ev3 Inc. (Plymouth, MN) recently received US Food and Drug
Administration 510(k) clearance for the PowerCross 0.018-inch overthe-
wire (OTW) percutaneous transluminal angioplasty (PTA) dilatation
catheter. PowerCross, the next generation in PTA balloon technology,
delivers a balance of excellent pushability, low crossing profile, and
reduced deflation times, the company stated. A strengthened catheter
design provides optimal pushability, and an increased internal lumen
provides greatly reduced deflation times. The PowerCross balloon is
available in lengths of 20 to 200 mm on 90- and 150-cm shafts. Two
additional marker bands in the center of the 150- and 200-mm length
balloons provide additional visibility under fluoroscopy. The PowerCross 0.018-inch OTW PTA dilatation catheter is intended to dilate stenoses in the iliac, femoral, iliofemoral, popliteal, infrapopliteal, and renal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for stent postdilatation in the peripheral vasculature.
Eclipse Vena Cava Filter
Bard Peripheral Vascular (Tempe,
AZ) recently announced Food and
Drug Administration clearance of
the Eclipse vena cava filter.
According to the company, the
Eclipse filter combines proven performance
with long-term retrievability
and improved surface finish.
The Eclipse vena cava filter utilizes a conical filter design in two offset layers that effectively trap large and small emboli without compromising caval patency. A specially designed pusher wire and articulated arms promote a centered filter placement, even through tortuous anatomy. Multiple retrieval options allow for safe and easy retrieval using an endovascular snare or the Recovery Cone removal system. The unique design of elastic hooks allow for atraumatic filter removal even after extended indwell times. The Eclipse vena cava filter is currently commercially available in the United States.
VascuTrak PTA Dilatation Catheter The VascuTrak PTA dilatation catheter (Bard Peripheral Vascular, Inc., Tempe, AZ) utilizes two external wires to focus the outward dilatation force of the balloon on the lesion. This focused force allows the balloon to dilate lesions at low inflation pressures. Additionally, the design of the balloon allows it to dilate in tortuous anatomy and calcified lesions. The VascuTrak PTA dilatation catheter is offered in lengths up to 300 mm, the longest on the market.
Reef HP PTA
Balloon Catheter
The Reef HP PTA balloon catheter
(Invatec Inc., Bethlehem, PA) recently
received US Food and Drug
Administration 510(k) clearance for
use in peripheral high-pressure dilatation
procedures. According to the
company, the lesion-specific design of
the balloon is particularly useful in
hard-to-dilate situations. “We often
encounter calcified and resistant
lesions in peripheral vessels and in hemodialysis access interventions,” commented
Robert L. Vogelzang, MD, Professor of Radiology at Northwestern
University Medical School and Chief of Vascular and Interventional
Radiology at Northwestern Memorial Hospital. “Invatec's addition of a highpressure
PTA balloon will aid in the successful treatment of these challenging
lesions.” The REEF HP balloon is made from Invatec's proprietary Flexitec
XF, an extremely durable material with a large working pressure range of up
to 22 atm, offering excellent control during high-pressure procedures. The
low-compliant balloon offers a uniform dilatation force and strong shape
retention to dilate resistive lesions with greater stability and success. The
balloon is now available in a wide range of sizes from diameters of 4 to 8
mm and lengths of 20 to 80 mm.
Valved One-Step
Merit Medical Systems, Inc.
(South Jordan, UT) is expanding its
centesis line of products with the
addition of the Valved One-Step
centesis drainage catheter. The
catheter incorporates a self-sealing
valve in the catheter hub to minimize
the risk of air infiltration and
fluid leakage during thoracentesis
and paracentesis procedures. The
patent-pending valve design may
be opened with either a needle or
luer fitting. When a syringe or
drainage tubing is connected to
the catheter, the valve fully opens to allow maximum drainage. Four
large drainage holes spiral around the catheter for maximum flow.
According to the company, inserting the catheter is easier with a new
tapered-tip design that provides excellent transition through the skin
and tissue. More accurate placement is achieved with the increased visibility
of the echo-enhanced needle.