Used in conjunction with the Boston Scientific Embolic Protection System, it is indicated for the treatment of patients at high risk for adverse events from carotid endarterectomy due to either anatomic or comorbid conditions who require carotid revascularization in the treatment of ipsilateral or bilateral carotid artery disease and meet the criteria outlined: patients with neurological symptoms and ≥ 50% stenosis of the common, internal carotid artery and/or the bifurcation by ultrasound or angiography of patients without neurological symptoms and ≥ 80% stenosis of the common, internal carotid artery and/or the bifurcation by ultrasound or angiogram, and patients with a reference vessel diameter within the range of 4–9 mm at the target lesion
Indicated for use in patients with carotid arterial atherosclerotic disease
InspireMD
CGuard Carotid Embolic Prevention Stent System
–
–
6, 7, 8, 9, 10
20, 30, 40, 60
Compatible with both distal and proximal embolic protection devices
–
–
Indicated for improving carotid luminal diameter in patients at high risk for adverse events from carotid endarterectomy who require carotid revascularization and meet the following criteria: patients with neurological symptoms and > 50% stenosis of the common or internal carotid artery by either ultrasound or angiogram or patients without neurological symptoms and > 80% stenosis of the common or internal carotid artery by either ultrasound or angiogram; patients having a vessel with reference diameters between 4.8–9 mm at the target lesion
Balton
Mer
7/5, 8/6, 9/7, 10/7, 10/8
20, 30, 40, 50
4, 5, 6, 7, 8, 9, 10
20, 30, 40, 50
Robin
Filter
Distal
Carotid artery stenting
Cordis
Precise Pro RX Carotid Stent System
Autotapering
20, 30, 40
5–10
20, 30, 40
Angioguard RX Emboli Capture Guidewire
Filter
Distal
Indicated for treatment of patients at high risk for adverse events from carotid endarterectomy who require carotid revascularization and meet the following criteria: patients with neurological symptoms and ≥ 50% stenosis of the common or internal carotid artery by ultrasound or angiography, or patients without neurological symptoms and ≥ 80% stenosis of the common or internal carotid artery by ultrasound or angiography, and patients must have a vessel diameter of 4–9 mm at the target lesion; the vessel distal to the target lesion must be within the range of 3–7.5 mm to allow for placement of Cordis Angioguard RX Guidewire
Medtronic
Protégé RX Carotid Stent System
8/6, 10/7
30, 40
6–10
20, 30, 40, 60
SpiderFX Embolic Protection Device
Filter; guidewire of choice
Distal
Indicated for treatment of stenoses of the common carotid artery, internal carotid artery, and carotid bifurcation
Terumo Europe
Roadsaver Carotid Artery Stent
–
–
5–10
16–40
Nanoparasol Embolic Protection System
Filter, concentric nitinol micromesh, guidewire of choice
Distal
Indicated for use in patients with carotid arterial atherosclerotic disease; indicated for use as a guidewire to contain and remove embolic material (thrombus/debris) while preforming angioplasty and stenting procedures in carotid arteries
Abbott
RX Acculink Carotid Stent System
8/6, 10/7
30, 40
5–10
20, 30, 40
Emboshield Nav6 Embolic Protection Systems
Filter; BareWire filter delivery wire
Distal
Indicated for use in patients with atherosclerotic disease of the carotid arteries
Abbott
X.Act Carotid Stent System
8/6, 9/7, 10/8
30, 40
7–10
20, 30
Emboshield Nav6 Embolic Protection System
Filter; BareWire filter delivery wire
Distal
Indicated for use in patients with atherosclerotic disease of the carotid arteries; indicated for use in conjunction with Abbott Vascular's Emboshield family of embolic protection systems