Group 7 Copy 3 Created with Sketch.
News Issue Archive Device Guide Calendar Subscribe Advertising

MENU

Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

News Current Issue Archive Device Guide Calendar Subscribe Advertising About Contact Privacy Submissions
Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

Back to Top

Advertisement

Advertisement

EURO Company Directory


B. Braun Melsungen AG

Sieversufer 8, 12359 Berlin, Germany

PHONE: +44 30 568207300 | FAX: +49 30 56837130

down-arrow Created with Sketch.
down-arrow Created with Sketch.

Balloons / Drug-Coated Balloons

View Chart
Company Name Product Name Drug Type Drug Concentration (µg/mm2) Excipient Type Guidewire Compatibility (inch) Shaft Length (cm) Sheath Compatibility (F) Balloon Diameters (mm) Balloon Lengths (cm)
B. Braun Melsungen AG SeQuent Please OTW 14 Paclitaxel 3 Resveratrol 0.014 130, 150 4 1.5, 2, 2.5, 3 4, 8, 12, 15
B. Braun Melsungen AG SeQuent Please OTW 18 Paclitaxel 3 Resveratrol 0.018 75, 130 4, 5, 6 2, 2.5, 3, 3.5, 4, 5, 6, 7, 8 4, 6, 8, 12, 15
B. Braun Melsungen AG SeQuent Please OTW 35 Paclitaxel 3 Resveratrol 0.035 75, 130 5, 6 4, 5, 6, 7, 8 4, 6, 8, 12, 15

Advertisement

Advertisement

Balloons / Specialty Balloons

View Chart
Company Name Product Name Nominal Pressure (atm) Rated Burst Pressure (atm) Guidewire Compatibility (inch) Size (F) Sheath Compatibility (F) Shaft Length (cm) Balloon Diameters (mm) Balloon Lengths (cm)
B. Braun Melsungen AG Aperta NSE PTA, PTA Scoring Balloon Catheter 10 14 (diameter 7 and 8); 20 (diameter 4 to 6) 0.018 4.9 5, 6 50, 90, 145 4, 5, 6, 7, 8 4

Sheaths / Special Access Sheaths

View Chart
Company Name Product Name Size (F) Length (cm) Guidewire Compatibility (inch) Curved or Straight Radiopaque Tip Type of Special Access
B. Braun Melsungen AG Intradyn Arterial Introducer Sheath and Kits 5–8 16 0.035 X 40 cm Straight No Designed for the introduction of catheters into the arterial vasculature using the Seldinger technique; full kits or separate sterile sheaths are available
B. Braun Melsungen AG Intradyn Special Introducer Sheath and Kits 6–9 20.5 0.035 X 70 cm Straight No Designed for the introduction of catheters into the venous vasculature using the Seldinger technique; full kits or separate sterile sheaths are available
B. Braun Melsungen AG Intradyn Tear-Away Introducer Sheaths and Kits 6–11 16 0.035 X 40 cm Straight No Designed for the introduction of catheters into the arterial vasculature using the Seldinger technique; full kits or separate sterile sheaths are available

Other Devices / Vena Cava Filters

View Chart
Company Name Product Name Indicated Caval Diameter (mm) (based on average caval diameter) Maximum Deployed Length (mm) Catheter Carrier System ID (F) Material Design Approach Permanent/Retrievable
B. Braun Melsungen AG VenaTech Convertible 14–28 60 7 Cobalt-chromium alloy Conical, self centering Brachial, femoral, jugular, subclavian Permanent, enables filter conversion to open configuration
B. Braun Melsungen AG VenaTech LP ≤ 35 43 7 Cobalt-chromium alloy Conical, self centering Brachial, femoral, jugular, subclavian Permanent
B. Braun Melsungen AG VenaTech Retrievable 14–28 53 7 (implantation), 10 (explantation) Cobalt-chromium alloy Conical Brachial, femoral, jugular, subclavian Retrievable

Other Devices / Inflation Devices

View Chart
Company Name Product Name Color Pressure Range (atm) Barrel Volume (mL) Luminescent Gauge (Yes/No) Gauge Latch Type Threads
B. Braun Melsungen AG AI25 Transparent/blue 30 20 No Luer lock Click and go Without

More Categories:

Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View All

Advertisement

Latest News


April 17, 2026

Bayer’s Asundexian FXIa Inhibitor Demonstrates Reduction in Ischemic Stroke in OCEANIC-STROKE Study

April 16, 2026

Rapid Medical’s Tigertriever 25 Cleared by FDA to Treat LVO Stroke

April 15, 2026

Stereotaxis to Acquire Robocath

Most Read Articles


A Private Practice Physician’s Experience Treating Chronic Venous Insufficiency

By Robert A. Edwards, DO

Update on Modern Complex Abdominal Aortic Repair Options

With Jason T. Lee, MD; Steven Maximus, MD, FACS; Gustavo Oderich, MD, FACS; Benjamin W. Starnes, MD, FACS; Carlos Timaran, MD; Kak Khee Yeung, MD, PhD, FEBVS; and Javairiah Fatima, MD, FACS, DFSVS

Transforming the Future of PE Care: Expanding Mechanical Thrombectomy Through Innovation

By Mehdi Shishehbor, DO, MPH, PhD

Back to Top
Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous
Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

News• Current Issue• Archive• Device Guide• Advertising• About Calendar• Contact• Privacy• Submissions• Subscriptions


Endovascular Today (ISSN 1551-1944 print and ISSN 2689-792X online) is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field.



magazine Created with Sketch.

Free Print Subscriptions

Fill 1 Created with Sketch.

Email Newsletter



twitter-icon LinkedIn Created with Sketch. instagram BlueSky-Circle
Cardiac Interventions Today
Group 7 Copy 3 Created with Sketch.
bmc-secondary-mark-color copy Created with Sketch.

© 2026 Bryn Mawr Communications II, LLC.  
All Rights Reserved   •   Privacy Policy

one-trust-button