Invamed
Mutlukent Mah 19 Sok, Hekimköy Sitesi, No. 10 Çankaya/Ankara, Turkey
PHONE: +90 (312) 235 77 35-36
Balloons / Drug-Coated Balloons
View Chart| Company Name | Product Name | Drug Type | Drug Concentration (µg/mm2) | Excipient Type | Guidewire Compatibility (inch) | Shaft Length (cm) | Sheath Compatibility (F) | Balloon Diameters (mm) | Balloon Lengths (cm) |
|---|---|---|---|---|---|---|---|---|---|
| Invamed | Extender | Paclitaxel | 3 | No excipient | 0.014, 0.018, 0.035 | 80, 90, 120, 135, 150 | 5, 6, 7 | 2, 2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6, 6.5, 7, 8, 9, 10 | 1.5, 2, 4, 6, 8, 9, 10, 12, 15, 22 |
Advertisement
Advertisement
Embolization / Embolic Particles/Beads
View Chart| Company Name | Product Name | Composition | Type | Sizes (µm) | Color Coded | CE Mark Indications |
|---|---|---|---|---|---|---|
| Invamed | Microsphere Drug Loadable Beads | NBCA particles | Irregularly shaped beads | 150–200 | One size; no coding | Embolization of hypervascular tumors, hepatic vascular tumors, including leiomyoma, uteri, and peripheral AVMs |
Embolization / Vascular Plugs
View Chart| Company Name | Product Name | Material | Sizes (mm) | Delivery Cable Length (cm) | Recommended Catheter Sizes (ID) (inch) | CE Mark Indications |
|---|---|---|---|---|---|---|
| Invamed | Embolization Plug | Hard gel | 1 mL | 135 | Microcatheter: 0.027 | To obstruct or reduce the rate of blood flow in the vasculature |
Other Devices / Atherectomy Devices
View Chart| Company Name | Product Name | Minimum Vessel Diameter (mm) | Sheath Compatibility (F) | Crossing Profile (inch) | Working Length (cm) | Tip Length (cm) |
|---|---|---|---|---|---|---|
| Invamed | Paragon | 3 | 7 | 0.090 | 150 | – |
Other Devices / Closure Devices
View Chart| Company Name | Product Name | Type | Puncture Size (F) | Maximum Wire Compatibility (inch) | Comments |
|---|---|---|---|---|---|
| Invamed | AngioBlock | Embolization seal | 5, 6, 7, 8 | 0.035 (5/6 F), 0.038 (7/8 F) | Developed for achieving rapid, reliable, and safe homeostasis after angiography entry; the delivery sheath allows the system to detect the artery and deliver the polymer compound over the adventitia of the artery |
Other Devices / Embolic Protection Devices
View Chart| Company Name | Product Name | Type | Position | CE Mark Indications |
|---|---|---|---|---|
| Invamed | Inca | Protective filter | Distal | Indicated for use as a guidewire and EPS to contain and remove embolic material while performing DVT carotid artery angioplasty, stenting procedures in carotid arteries; suitable for acute PE, VTE, and ICU thrombectomy |
Other Devices / Endovenous Ablation
View Chart| Company Name | Product Name | Technology | Wavelength (nm) | Sheath Size (F) | Sheath Length (cm) | CE Mark Indications |
|---|---|---|---|---|---|---|
| Invamed | Filler | Polymer (n-BCA) | – | 6 | 90 | Treatment of iliac artery aneurysms, AAAs, and endoleaks using polymer n-BCA |
| Invamed | ThermaBlock | Handheld endovenous radiofrequency ablation catheter (without generator) | All | 6 | 100 | Treatment of the great saphenous vein and the small saphenous vein; no generator is needed; disposable |
| Invamed | Veinoff | Polymer | – | – | – | Treatment of varicose veins (tributary veins) by a simple ablative polymerization method; small amounts of polymer (OCA) injected endovenously by a butterfly catheter and small injector system |
| Invamed | VenaBlock | Delivery system | – | 6 | 90 | Treatment of venous insufficiency; indicated for use in the permanent closure of lower extremity superficial truncal veins, such as the great saphenous vein and perforator vein, continuously while applying pressure over the target vein segment |
| Invamed | VenaBlock Automated System | Delivery system | – | 6 | 200 | Treatment of venous insufficiency; indicated for use in the permanent closure of lower extremity superficial truncal veins, such as the great saphenous vein and perforator vein, continuously while applying pressure over the target vein segment automatically |
Other Devices / Mechanical Thrombectomy/Thrombolysis (Peripheral/Venous)
View Chart| Company Name | Product Name | Sheath Compatibility (F) | Guidewire Compatibility (inch) | Working Length (cm) | Mode of Operation | CE Mark Indications |
|---|---|---|---|---|---|---|
| Invamed | Mantis | 7 | – | 90 | Battery-operated, handheld drive unit initiates the mechanical rotation of an atraumatic unique loop shape with aspiration | DVT pharmacomechanical declotting and controlled and selective infusion of physician-specified fluids, including thrombolytics, in the peripheral vasculature; double engine volume, low and high speed options; hydrophilic tip |
| Invamed | Viper | 5 | 0.035 | 200 | Designed for controlled infusion of tPA along with mechanical vibrations | Over the guidewire system and 200 cm catheter length allows safe access to closed target vessels including pulmonary artery in PE cases |
Other Devices / Occlusion Devices
View Chart| Company Name | Product Name | Type | Position | CE Mark Indications |
|---|---|---|---|---|
| Invamed | ICT Paravalvular Leak Closure Device | Hard gel | Deliverable by the delivery system | Temporarily occlude and close valvular leaks in deep venous insufficiency |
Other Devices / Thrombus Aspiration Devices
View Chart| Company Name | Product Name | Type | Maximum Tip Diameter (mm) | Minimum Guide Catheter Size (F) | Catheter Length (cm) |
|---|---|---|---|---|---|
| Invamed | Dovi | Aspiration catheter with mechanical aspirator | 0.5 | 7 | 90 |
Other Devices / Vena Cava Filters
View Chart| Company Name | Product Name | Indicated Caval Diameter (mm) (based on average caval diameter) | Maximum Deployed Length (mm) | Catheter Carrier System ID (F) | Material | Design | Approach | Permanent/Retrievable |
|---|---|---|---|---|---|---|---|---|
| Invamed | Keeper | 33 | 50 | 8 | Nitinol/MRI compatible | Self centering | Femoral/jugular | Optional (permanent or retrievable) |