Abbott |
Amplatzer Vascular Plug (AVP)
|
Nitinol |
10–12 |
135 |
Guide catheter: 0.067 |
Arterial and venous embolization in the peripheral vasculature |
|
Abbott |
Amplatzer Vascular Plug (AVP)
|
Nitinol |
14–16 |
135 |
Guide catheter: 0.088 |
Arterial and venous embolization in the peripheral vasculature |
|
Abbott |
Amplatzer Vascular Plug (AVP)
|
Nitinol |
4–8 |
135 |
Guide catheter: 0.056 |
Arterial and venous embolization in the peripheral vasculature |
|
Abbott |
Amplatzer Vascular Plug 4 (AVP 4)
|
Nitinol |
4–8 |
155 |
Diagnostic catheter: 0.038 guidewire compatible |
Arterial and venous embolization in the peripheral vasculature |
|
Abbott |
Amplatzer Vascular Plug II (AVP II)
|
Nitinol |
10–12 |
135 |
Guide catheter: 0.070 |
Arterial and venous embolization in the peripheral vasculature |
|
Abbott |
Amplatzer Vascular Plug II (AVP II)
|
Nitinol |
14–16 |
135 |
Guide catheter: 0.086 |
Arterial and venous embolization in the peripheral vasculature |
|
Abbott |
Amplatzer Vascular Plug II (AVP II)
|
Nitinol |
18–22 |
135 |
Guide catheter: 0.098 |
Arterial and venous embolization in the peripheral vasculature |
|
Abbott |
Amplatzer Vascular Plug II (AVP II)
|
Nitinol |
3–8 |
135 |
Guide catheter: 0.056 |
Arterial and venous embolization in the peripheral vasculature |
|
Invamed |
Embolization Plug
|
Hard gel |
1 mL |
135 |
Microcatheter: 0.027 |
To obstruct or reduce the rate of blood flow in the vasculature |
|
ArtVentive Medical Group, Inc. |
Endoluminal Occlusion System (EOS)
|
Nitinol coil with PTFE plug |
5, 8, 11 |
105 |
0.067, 0.082 |
Immediate arterial and venous embolization in the peripheral vasculature |
|
Shape Memory Medical Inc. |
IMP-05, Impede Embolization Plug
|
Proprietary porous shape memory polyurethane, nitinol, platinum alloy |
Vessel diameter, 2–5 |
– |
0.038–0.057 |
To obstruct or reduce the rate of blood flow in the peripheral vasculature |
|
Shape Memory Medical Inc. |
IMP-07, Impede Embolization Plug
|
Proprietary porous shape memory polyurethane, nitinol, platinum alloy |
Vessel diameter, 4–7 |
– |
0.055–0.071 |
To obstruct or reduce the rate of blood flow in the peripheral vasculature |
|
Shape Memory Medical Inc. |
IMP-10, Impede Embolization Plug
|
Proprietary porous shape memory polyurethane, nitinol, platinum alloy |
Vessel diameter, 6–10 |
– |
0.070–0.090 |
To obstruct or reduce the rate of blood flow in the peripheral vasculature |
|
Shape Memory Medical Inc. |
IMP-FX-06, Impede FX Embolization Plug
|
Proprietary porous shape memory polyurethane, platinum alloy |
6 (expanded diameter) X 10 (length) |
– |
0.038–0.057 |
To obstruct or reduce the rate of blood flow in the peripheral vasculature |
|
Shape Memory Medical Inc. |
IMP-FX-08, Impede FX Embolization Plug
|
Proprietary porous shape memory polyurethane, platinum alloy |
8 (expanded diameter) X 10 (length) |
– |
0.055–0.071 |
To obstruct or reduce the rate of blood flow in the peripheral vasculature |
|
Shape Memory Medical Inc. |
IMP-FX-12, Impede FX Embolization Plug
|
Proprietary porous shape memory polyurethane, platinum alloy |
12 (expanded diameter) X 15 (length) |
– |
0.070–0.090 |
To obstruct or reduce the rate of blood flow in the peripheral vasculature |
|
Shape Memory Medical Inc. |
IMP-FX-12x5, Impede FX Rapid Fill Embolization Plug
|
Proprietary porous shape memory polyurethane, platinum alloy |
12 (expanded diameter) X 15 (length) |
– |
0.070–0.090 |
To obstruct or reduce the rate of blood flow in the peripheral vasculature |
|
Medtronic |
MVP-3 Micro Vascular Plug System
|
Nitinol and PTFE |
1.5–3 |
180 |
Microcatheter: 0.021 |
To obstruct or reduce the rate of blood flow in the peripheral vasculature |
|
Medtronic |
MVP-5 Micro Vascular Plug System
|
Nitinol and PTFE |
3–5 |
180 |
Microcatheter: 0.027 |
To obstruct or reduce the rate of blood flow in the peripheral vasculature |
|
Medtronic |
MVP-7 Micro Vascular Plug System
|
Nitinol and PTFE |
5–7 |
165 |
4 F |
To obstruct or reduce the rate of blood flow in the peripheral vasculature |
|
Medtronic |
MVP-9 Micro Vascular Plug System
|
Nitinol and PTFE |
7–9 |
165 |
5 F |
To obstruct or reduce the rate of blood flow in the peripheral vasculature |