Aortic (AAA) / Main Body Grafts
View Chart| Company Name | Product Name | Main Body Diameter (mm) | Main Body Length (cm) | Main Body Delivery System Profile: Device OD (F) | Sheath Required for Delivery | Delivery Sheath OD (F) | Fixation Location | Stent Expansion | Stent Material | Graft Material | Comments |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Gore & Associates | Gore Excluder Conformable AAA Endoprosthesis with Active Control System | 20,* 23,* 26,* 28.5,* 32,† 36† | 12,* 14† | 16, 18 | Yes | 18.3, 20.1 | Infrarenal | Self expanding | Nitinol | ePTFE | *20, 23, 26, 28.5-mm graft lengths: 12 cm; †32- and 36-mm graft lengths: 14 cm |
| Gore & Associates | Gore Excluder AAA Endoprosthesis featuring C3 Delivery System | 23,* 26,* 28.5,* 31,† 35‡ | 12, 13, 14, 15, 16, 17, 18 | 16, 18 | Yes | 18.3, 20.1 | Infrarenal | Self expanding | Nitinol | ePTFE | *23, 26, and 28.5-mm graft lengths: 12, 14, 16, 18 cm; †31-mm graft lengths: 13, 15, 17 cm; ‡35-mm graft lengths: 14, 16, 18 cm |
Advertisement
Advertisement
Aortic (AAA) / Iliac Limbs
View Chart| Company Name | Product Name | Iliac Limb Diameter (mm) | Iliac Limb Length (cm) | Comments |
|---|---|---|---|---|
| Gore & Associates | Gore Excluder AAA Endoprosthesis | 12, 14.5, 16, 18, 20, 23, 27 | 9.5,* 10, 11.5,* 12, 13.5,* 14 | *Lengths for 16-, 18-, and 20-mm diameter grafts only |
Aortic (AAA) / Iliac Branch
View Chart| Company Name | Product Name | Common Iliac Artery Length (cm) | External Artery Length (cm) | Distal Device Diameter (mm) | Proximal Device Diameter (mm) | Branch Diameter (mm) | Delivery System Profile: Device OD (mm) | Sheath Required for Delivery | Delivery Sheath OD (F) | Fixation Location | Stent Expansion | Stent Material | Graft Material |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Gore & Associates | Gore Excluder Iliac Branch Component | 5.5 (can be deployed above aortic bifurcation) | 4.5 | 10, 12, 14.5 | 23 | 13 | 6.2 | Yes | 18.3 | Internal and external iliac artery | Self expanding | Nitinol | ePTFE |
| Gore & Associates | Gore Excluder Internal Iliac Component | – | 4.5 (internal artery length) | 10, 12, 14.5 | 16 | – | 5 | Yes | 14.1 | Internal iliac artery | Self expanding | Nitinol | ePTFE |
Aortic (AAA) / Ancillary Components
View Chart| Company Name | Product Name | Main Body Extensions Diameter (mm) | Main Body Extensions Length (cm) | Iliac Leg Extensions Diameter (mm) | Iliac Leg Extensions Length (cm) | Aorto-Uni-Iliac/Converter Proximal Diameter (mm) | Aorto-Uni-Iliac/Converter Length (cm) | Occluders Diameter (mm) | Comments |
|---|---|---|---|---|---|---|---|---|---|
| Gore & Associates | Gore Excluder AAA Endoprosthesis | 20, 23, 26, 28.5, 32, 36 | 3.3, 4.5 | 10, 12, 14.5, 16, 18, 20, 23, 27 | 7,* 9.5,† 10, 11.5,† 12, 13.5,† 14 | – | – | – | *Length is for 10-, 12-, and 14.5-mm diameter only; 10-mm diameter only comes with a 7-cm length; †lengths are for 16-, 18-, and 20-mm diameter grafts only |
Aortic (AAA) / Occlusion/Molding Balloons
View Chart| Company Name | Product Name | Size (F) | Recommended Introducer Size (F) | Guidewire Compatibility (inch) | Catheter Length (cm) | Maximum Inflated Balloon Diameter (mm) |
|---|---|---|---|---|---|---|
| Gore & Associates | Gore Molding & Occlusion Balloon | 10 | 10 | 0.035 | 90 | 37 |
Aortic (AAA) / Other Accessories
View Chart| Company Name | Product Name | Size (F) | Guidewire Compatibility (inch) | Comments |
|---|---|---|---|---|
| Gore & Associates | Gore DrySeal Flex Introducer Sheath | 10, 12, 14, 15, 16, 18, 20, 22, 24, 26 | 0.035 | A new standard of flexibility to treat more challenging anatomies |
| Gore & Associates | Gore Tri-Lobe Balloon Catheter | 18 | 0.035 | Unique Tri-Lobe design allows for continuous blood flow |
Aortic (TAA) / Thoracic Stent Grafts
View Chart| Company Name | Product Name | Stent Material | Graft Material | Stent Expansion | Length (cm) | Diameter (mm) | Sheath Required for Delivery | Sheath Compatibility (F) |
|---|---|---|---|---|---|---|---|---|
| Gore & Associates | Gore TAG Conformable Thoracic Stent Graft With Active Control System | Nitinol | ePTFE | Self expanding | 10, 15, 20 | 21, 26, 28, 31, 34, 37, 40, 45; tapered: 26 X 21, 31 X 26 | Yes | 18, 20, 22, 24 (ID) |
Aortic (TAA) / Occlusion/Molding Balloons
View Chart| Company Name | Product Name | Size (F) | Recommended Introducer Size (F) | Guidewire Compatibility (inch) | Catheter Length (cm) | Maximum Inflated Balloon Diameter (mm) |
|---|---|---|---|---|---|---|
| Gore & Associates | Gore Tri-Lobe Balloon Catheter | 18 | 18 | 0.035 | 100 | 32, 42 |
Aortic (TAA) / Other Accessories
View Chart| Company Name | Product Name | Sizing (F) | Guidewire Compatibility (inch) | Comments |
|---|---|---|---|---|
| Gore & Associates | Gore DrySeal Flex Introducer Sheath | 10, 12, 14, 15, 16, 18, 20, 22, 24, 26 | 0.035 | A new standard of flexibility to treat more challenging anatomies |
| Gore & Associates | Gore Tri-Lobe Balloon Catheter | 18 | 0.035 | – |
Sheaths / Special Access Sheaths
View Chart| Company Name | Product Name | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Curved or Straight | Radiopaque Tip | Type of Special Access |
|---|---|---|---|---|---|---|---|
| Gore & Associates | Gore DrySeal Flex Introducer Sheath | 10, 12, 14, 15, 16, 18, 20, 22, 24, 26 | 33, 45, 65 | 0.035 | Flexible | Yes | Percutaneous |
Sheaths / Standard Sheaths
View Chart| Company Name | Product Name | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Curved or Straight | Radiopaque Tip |
|---|---|---|---|---|---|---|
| Gore & Associates | Gore DrySeal Flex Introducer Sheath | 10, 12, 14, 15, 16, 18, 20, 22, 24, 26 | 33, 45, 65 | 0.035 | Flexible | Yes |
Stents / Balloon-Expandable Covered Stents
View Chart| Company Name | Product Name | Material Used | Maximum Guidewire Size (inch) | Introducer Size (F) | Stent Diameter (mm) | Stent Length (mm) | Delivery System Length (cm) | CE Mark Indications |
|---|---|---|---|---|---|---|---|---|
| Gore & Associates | Gore Viabahn VBX Balloon-Expandable Endoprosthesis | Stainless steel stent/fluoropolymer graft | 0.035 | 7, 8 | 5, 6, 7, 8, 8L, 9, 10, 11 | 15, 19, 29, 39, 59, 79 | 135 | De novo or restenotic lesions in the iliac arteries, including lesions at the aortic bifurcation; de novo or restenotic lesions in the visceral arteries; isolated visceral, iliac, and subclavian artery aneurysms; or traumatic or iatrogenic vessel injuries in arteries that are located in the chest cavity, abdominal cavity, or pelvis (except for aorta, coronary, innominate, carotid, vertebral, and pulmonary arteries) |
Stents / Self-Expanding Stent Grafts
View Chart| Company Name | Product Name | Materials Used | Introducer Size (F) | Guidewire Compatibility (inch) | Stent Diameter (mm) | Stent Length (mm) | Delivery System Length (cm) | CE Mark Indications | Comments |
|---|---|---|---|---|---|---|---|---|---|
| Gore & Associates | Gore Viabahn Endoprosthesis With Propaten Bioactive Surface | Nitinol/ePTFE, gold | 6–10 | 0.018/0.014 (5–8 mm), 0.035 (5–13 mm) | 5, 6, 7, 8, 9, 10, 11, 13 | 25, 50, 75, 100, 150, 250 | 75 (0.035-inch system only), 120 | Indicated for the treatment of de novo or restenotic lesions in the iliac arteries; de novo or restenotic lesions in the superficial femoral artery and proximal popliteal artery; in-stent restenotic lesions in the superficial femoral artery and proximal popliteal artery; stenosis or thrombotic occlusion at the venous anastomosis of synthetic arteriovenous (AV) access grafts and in the venous outflow of dialysis access circuits, including the central veins; popliteal artery aneurysms and isolated visceral artery aneurysms; traumatic or iatrogenic vessel injuries in arteries that are located in the chest cavity, abdominal cavity, or pelvis (except for aorta, coronary, innominate, carotid, vertebral, and pulmonary arteries) | – |
| Gore & Associates | Gore Viabil Biliary Endoprosthesis | Nitinol/ePTFE | 8.5 (endoscopic), 10 (percutaneous) | 0.035 | 8, 10 | 40, 60, 80, 100 | 40 (percutaneous), 200 (endoscopic) | Benign* and malignant biliary strictures† | *Devices without transmural drainage holes; †Contraindicated for all cardiovascular applications |
| Gore & Associates | Gore Viatorr TIPS Endoprosthesis With Controlled Expansion | Nitinol/ePTFE | 10 | ≤ 0.035 | 8–10 | 60, 70, 80, 90, 100 | 75 | Indicated for use in the treatment of portal hypertension and its complications such as variceal bleeding and refractory ascites | TIPS, transjugular intrahepatic portosystemic shunt |
More Categories:
Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View AllAdvertisement