Gore & Associates

Unternehmensbereich Medizin, Hermann-Oberth - Str. 22 85640 Putzbrunn, Deutschland

PHONE: +49 89 46 12 0 | FAX: +49 89 46 12 2448

down-arrow Created with Sketch.
down-arrow Created with Sketch.

Aortic (AAA) / Main Body Grafts

View Chart
Company Name Product Name Main Body Diameter (mm) Main Body Length (cm) Main Body Delivery System Profile: Device OD (F) Sheath Required for Delivery Delivery Sheath OD (F) Fixation Location Stent Expansion Stent Material Graft Material Comments
Gore & Associates Gore Excluder Conformable AAA Endoprosthesis with Active Control System 20,* 23,* 26,* 28.5,* 32,† 36† 12,* 14† 16, 18 Yes 18.3, 20.1 Infrarenal Self expanding Nitinol ePTFE *20, 23, 26, 28.5-mm graft lengths: 12 cm; †32- and 36-mm graft lengths: 14 cm
Gore & Associates Gore Excluder AAA Endoprosthesis featuring C3 Delivery System 23,* 26,* 28.5,* 31,† 35‡ 12, 13, 14, 15, 16, 17, 18 16, 18 Yes 18.3, 20.1 Infrarenal Self expanding Nitinol ePTFE *23, 26, and 28.5-mm graft lengths: 12, 14, 16, 18 cm; †31-mm graft lengths: 13, 15, 17 cm; ‡35-mm graft lengths: 14, 16, 18 cm

Advertisement

Advertisement

Aortic (AAA) / Iliac Limbs

View Chart
Company Name Product Name Iliac Limb Diameter (mm) Iliac Limb Length (cm) Comments
Gore & Associates Gore Excluder AAA Endoprosthesis 12, 14.5, 16, 18, 20, 23, 27 9.5,* 10, 11.5,* 12, 13.5,* 14 *Lengths for 16-, 18-, and 20-mm diameter grafts only

Aortic (AAA) / Iliac Branch

View Chart
Company Name Product Name Common Iliac Artery Length (cm) External Artery Length (cm) Distal Device Diameter (mm) Proximal Device Diameter (mm) Branch Diameter (mm) Delivery System Profile: Device OD (mm) Sheath Required for Delivery Delivery Sheath OD (F) Fixation Location Stent Expansion Stent Material Graft Material
Gore & Associates Gore Excluder Iliac Branch Component 5.5 (can be deployed above aortic bifurcation) 4.5 10, 12, 14.5 23 13 6.2 Yes 18.3 Internal and external iliac artery Self expanding Nitinol ePTFE
Gore & Associates Gore Excluder Internal Iliac Component – 4.5 (internal artery length) 10, 12, 14.5 16 – 5 Yes 14.1 Internal iliac artery Self expanding Nitinol ePTFE

Aortic (AAA) / Ancillary Components

View Chart
Company Name Product Name Main Body Extensions Diameter (mm) Main Body Extensions Length (cm) Iliac Leg Extensions Diameter (mm) Iliac Leg Extensions Length (cm) Aorto-Uni-Iliac/Converter Proximal Diameter (mm) Aorto-Uni-Iliac/Converter Length (cm) Occluders Diameter (mm) Comments
Gore & Associates Gore Excluder AAA Endoprosthesis 20, 23, 26, 28.5, 32, 36 3.3, 4.5 10, 12, 14.5, 16, 18, 20, 23, 27 7,* 9.5,† 10, 11.5,† 12, 13.5,† 14 – – – *Length is for 10-, 12-, and 14.5-mm diameter only; 10-mm diameter only comes with a 7-cm length; †lengths are for 16-, 18-, and 20-mm diameter grafts only

Aortic (AAA) / Occlusion/Molding Balloons

View Chart
Company Name Product Name Size (F) Recommended Introducer Size (F) Guidewire Compatibility (inch) Catheter Length (cm) Maximum Inflated Balloon Diameter (mm)
Gore & Associates Gore Molding & Occlusion Balloon 10 10 0.035 90 37

Aortic (AAA) / Other Accessories

View Chart
Company Name Product Name Size (F) Guidewire Compatibility (inch) Comments
Gore & Associates Gore DrySeal Flex Introducer Sheath 10, 12, 14, 15, 16, 18, 20, 22, 24, 26 0.035 A new standard of flexibility to treat more challenging anatomies
Gore & Associates Gore Tri-Lobe Balloon Catheter 18 0.035 Unique Tri-Lobe design allows for continuous blood flow

Aortic (TAA) / Thoracic Stent Grafts

View Chart
Company Name Product Name Stent Material Graft Material Stent Expansion Length (cm) Diameter (mm) Sheath Required for Delivery Sheath Compatibility (F)
Gore & Associates Gore TAG Conformable Thoracic Stent Graft With Active Control System Nitinol ePTFE Self expanding 10, 15, 20 21, 26, 28, 31, 34, 37, 40, 45; tapered: 26 X 21, 31 X 26 Yes 18, 20, 22, 24 (ID)

Aortic (TAA) / Occlusion/Molding Balloons

View Chart
Company Name Product Name Size (F) Recommended Introducer Size (F) Guidewire Compatibility (inch) Catheter Length (cm) Maximum Inflated Balloon Diameter (mm)
Gore & Associates Gore Tri-Lobe Balloon Catheter 18 18 0.035 100 32, 42

Aortic (TAA) / Other Accessories

View Chart
Company Name Product Name Sizing (F) Guidewire Compatibility (inch) Comments
Gore & Associates Gore DrySeal Flex Introducer Sheath 10, 12, 14, 15, 16, 18, 20, 22, 24, 26 0.035 A new standard of flexibility to treat more challenging anatomies
Gore & Associates Gore Tri-Lobe Balloon Catheter 18 0.035 –

Sheaths / Special Access Sheaths

View Chart
Company Name Product Name Size (F) Length (cm) Guidewire Compatibility (inch) Curved or Straight Radiopaque Tip Type of Special Access
Gore & Associates Gore DrySeal Flex Introducer Sheath 10, 12, 14, 15, 16, 18, 20, 22, 24, 26 33, 45, 65 0.035 Flexible Yes Percutaneous

Sheaths / Standard Sheaths

View Chart
Company Name Product Name Size (F) Length (cm) Guidewire Compatibility (inch) Curved or Straight Radiopaque Tip
Gore & Associates Gore DrySeal Flex Introducer Sheath 10, 12, 14, 15, 16, 18, 20, 22, 24, 26 33, 45, 65 0.035 Flexible Yes

Stents / Balloon-Expandable Covered Stents

View Chart
Company Name Product Name Material Used Maximum Guidewire Size (inch) Introducer Size (F) Stent Diameter (mm) Stent Length (mm) Delivery System Length (cm) CE Mark Indications
Gore & Associates Gore Viabahn VBX Balloon-Expandable Endoprosthesis Stainless steel stent/fluoropolymer graft 0.035 7, 8 5, 6, 7, 8, 8L, 9, 10, 11 15, 19, 29, 39, 59, 79 135 De novo or restenotic lesions in the iliac arteries, including lesions at the aortic bifurcation; de novo or restenotic lesions in the visceral arteries; isolated visceral, iliac, and subclavian artery aneurysms; or traumatic or iatrogenic vessel injuries in arteries that are located in the chest cavity, abdominal cavity, or pelvis (except for aorta, coronary, innominate, carotid, vertebral, and pulmonary arteries)

Stents / Self-Expanding Stent Grafts

View Chart
Company Name Product Name Materials Used Introducer Size (F) Guidewire Compatibility (inch) Stent Diameter (mm) Stent Length (mm) Delivery System Length (cm) CE Mark Indications Comments
Gore & Associates Gore Viabahn Endoprosthesis With Propaten Bioactive Surface Nitinol/ePTFE, gold 6–10 0.018/0.014 (5–8 mm), 0.035 (5–13 mm) 5, 6, 7, 8, 9, 10, 11, 13 25, 50, 75, 100, 150, 250 75 (0.035-inch system only), 120 Indicated for the treatment of de novo or restenotic lesions in the iliac arteries; de novo or restenotic lesions in the superficial femoral artery and proximal popliteal artery; in-stent restenotic lesions in the superficial femoral artery and proximal popliteal artery; stenosis or thrombotic occlusion at the venous anastomosis of synthetic arteriovenous (AV) access grafts and in the venous outflow of dialysis access circuits, including the central veins; popliteal artery aneurysms and isolated visceral artery aneurysms; traumatic or iatrogenic vessel injuries in arteries that are located in the chest cavity, abdominal cavity, or pelvis (except for aorta, coronary, innominate, carotid, vertebral, and pulmonary arteries) –
Gore & Associates Gore Viabil Biliary Endoprosthesis Nitinol/ePTFE 8.5 (endoscopic), 10 (percutaneous) 0.035 8, 10 40, 60, 80, 100 40 (percutaneous), 200 (endoscopic) Benign* and malignant biliary strictures† *Devices without transmural drainage holes; †Contraindicated for all cardiovascular applications
Gore & Associates Gore Viatorr TIPS Endoprosthesis With Controlled Expansion Nitinol/ePTFE 10 ≤ 0.035 8–10 60, 70, 80, 90, 100 75 Indicated for use in the treatment of portal hypertension and its complications such as variceal bleeding and refractory ascites TIPS, transjugular intrahepatic portosystemic shunt

More Categories:

Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View All

Advertisement

Latest News


April 17, 2026

Bayer’s Asundexian FXIa Inhibitor Demonstrates Reduction in Ischemic Stroke in OCEANIC-STROKE Study

April 16, 2026

Rapid Medical’s Tigertriever 25 Cleared by FDA to Treat LVO Stroke

April 15, 2026

Stereotaxis to Acquire Robocath

Most Read Articles


A Private Practice Physician’s Experience Treating Chronic Venous Insufficiency

By Robert A. Edwards, DO

Update on Modern Complex Abdominal Aortic Repair Options

With Jason T. Lee, MD; Steven Maximus, MD, FACS; Gustavo Oderich, MD, FACS; Benjamin W. Starnes, MD, FACS; Carlos Timaran, MD; Kak Khee Yeung, MD, PhD, FEBVS; and Javairiah Fatima, MD, FACS, DFSVS

Transforming the Future of PE Care: Expanding Mechanical Thrombectomy Through Innovation

By Mehdi Shishehbor, DO, MPH, PhD

Back to Top
Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous
Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

News• Current Issue• Archive• Device Guide• Advertising• About Calendar• Contact• Privacy• Submissions• Subscriptions


Endovascular Today (ISSN 1551-1944 print and ISSN 2689-792X online) is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field.



magazine Created with Sketch.

Free Print Subscriptions

Fill 1 Created with Sketch.

Email Newsletter



twitter-icon LinkedIn Created with Sketch. instagram BlueSky-Circle
Cardiac Interventions Today
Group 7 Copy 3 Created with Sketch.
bmc-secondary-mark-color copy Created with Sketch.

© 2026 Bryn Mawr Communications II, LLC.  
All Rights Reserved   •   Privacy Policy

one-trust-button