Advertisement
Advertisement
Gore & Associates
1505 N. 4th St., Flagstaff, AZ 86001
PHONE: (800) 437-8181
Aortic (AAA) / Main Body Grafts
View Chart| Company Name | Product Name | Main Body Diameter (mm) | Main Body Length (cm) | Main Body Delivery System Profile: Device OD (F) | Sheath Required for Delivery | Delivery Sheath OD (F) | Fixation Location | Stent Expansion | Stent Material | Graft Material | Comments |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Gore & Associates | Gore Excluder Conformable AAA Endoprosthesis Featuring Active Control | 20, 23, 26, 28.5, 32, 36 | 12 (20–28.5-mm grafts); 14 (32-, 36-mm grafts) | 15 (20-, 23-mm grafts); 16 (26-, 28.5-mm grafts); 18 (32-, 36-mm grafts) | Yes | 16.8, 18.3, 20.1 | Infrarenal | Self expanding | Nitinol | ePTFE | – |
| Gore & Associates | Gore Excluder AAA Endoprosthesis featuring C3 Delivery System | 23, 26, 28.5, 31, 35 | 12, 14, 16, 18 (23–28.5-mm grafts); 13, 15, 17 (31-mm graft); 14, 16, 18 (35-mm grafts) | 16 (23-, 26-mm grafts); 18 (28.5–35-mm grafts) | Yes | 18.3, 20.1 | Infrarenal | Self expanding | Nitinol | ePTFE | 23-, 26-, and 28.5-mm graft lengths: 12, 14, 16, 18 cm; 31-mm graft lengths: 13, 15, 17 cm; 35-mm graft lengths: 14, 16, 18 cm |
Advertisement
Advertisement
Aortic (AAA) / Iliac Limbs
View Chart| Company Name | Product Name | Iliac Limb Diameter (mm) | Iliac Limb Length (cm) | Comments |
|---|---|---|---|---|
| Gore & Associates | Gore Excluder AAA Endoprosthesis | 10, 12, 14.5, 16, 18, 20, 23, 27 | 9.5,* 10, 11.5,* 12, 13.5,* 14 | *Lengths for 16-, 18-, and 20-mm diameter grafts only |
Aortic (AAA) / Iliac Branch
View Chart| Company Name | Product Name | Common Iliac Artery Length (cm) | External Artery Length (cm) | Distal Device Diameter (mm) | Proximal Device Diameter (mm) | Branch Diameter (mm) | Delivery System Profile: Device OD (mm) | Sheath Required for Delivery | Delivery Sheath OD (F) | Fixation Location | Stent Expansion | Stent Material | Graft Material |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Gore & Associates | Gore Excluder Iliac Branch Component | 5.5 (can be deployed above aortic bifurcation) | 4.5 | 10, 12, 14.5 | 23 | 13 | 5.3 | Yes | 18.3 | Internal and external iliac artery | Self expanding | Nitinol | ePTFE |
| Gore & Associates | Gore Excluder Internal Iliac Component | – | 4.5 (internal artery length) | 10, 12, 14.5 | 16 | – | 4 | Yes | 14 | Internal iliac artery | Self expanding | Nitinol | ePTFE |
Aortic (AAA) / Ancillary Components
View Chart| Company Name | Product Name | Main Body Extensions Diameter (mm) | Main Body Extensions Length (cm) | Iliac Leg Extensions Diameter (mm) | Iliac Leg Extensions Length (cm) | Aorto-Uni-Iliac/Converter Proximal Diameter (mm) | Aorto-Uni-Iliac/Converter Length (cm) | Occluders Diameter (mm) | Comments |
|---|---|---|---|---|---|---|---|---|---|
| Gore & Associates | Gore Excluder AAA Endoprosthesis | 23, 26, 28.5, 32, 36 | 3.3 (23–28.5 mm), 4.5 (32, 36 mm) | 10, 12, 14.5, 16, 18, 20, 23, 27 | 7 (10-, 12-, 14.5-mm diameters); 9.5, 11.5, 13.5 (16-, 18-, 20-mm diameters); 10, 12, 14 (12-, 14-, 23-, 27-mm diameters) | – | – | – | – |
| Gore & Associates | Gore Excluder Conformable AAA Endoprosthesis Featuring Active Control | 20, 23, 26, 28.5, 32, 36 | 4.5 | 10, 12, 14.5, 16, 18, 20, 23, 27 | 7 (10-, 12-, 14.5-mm diameters); 9.5, 11.5, 13.5 (16-, 18-, 20-mm diameters); 10, 12, 14 (12-, 14-, 23-, 27-mm diameters) | – | – | – | – |
Catheters / Specialty Catheters
View Chart| Company Name | Product Name | Catheter Size (F) | Working Length (cm) | Minimum Guiding Catheter ID (inch) | Comments |
|---|---|---|---|---|---|
| Gore & Associates | Gore Tri-Lumen Catheter | 12 | 140 | 0.035 | Multi-lumen catheter comprised of a central lumen and two auxiliary lumens |
Sheaths / Special Access Sheaths
View Chart| Company Name | Product Name | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Curved or Straight | Radiopaque Tip | Type of Special Access |
|---|---|---|---|---|---|---|---|
| Gore & Associates | Gore DrySeal Flex Introducer Sheath | 10, 12, 14, 15, 16, 18, 20, 22, 24, 26 | 33, 45, 65 | 0.035 | Flexible | Yes | Percutaneous |
Sheaths / Standard Sheaths
View Chart| Company Name | Product Name | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Curved or Straight | Radiopaque Tip |
|---|---|---|---|---|---|---|
| Gore & Associates | Gore DrySeal Flex Introducer Sheath | 10, 12, 14, 15, 16, 18, 20, 22, 24, 26 | 33, 45, 65 | 0.035 | Flexible | Yes |
Stents / Balloon-Expandable Covered Stents
View Chart| Company Name | Product Name | Material Used | Maximum Guidewire Size (inch) | Introducer Size (F) | Stent Diameter (mm) | Stent Length (mm) | Delivery System Length (cm) | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|---|
| Gore & Associates | Gore Viabahn VBX Balloon Expandable Endoprosthesis | Stainless steel stent/fluoropolymer graft | 0.035 | 6, 7, 8 | 5, 6, 7, 8, 8L, 9, 10, 11 | 15, 19, 29, 39, 59, 79 | 80, 135 | Treatment of de novo or restenotic lesions found in iliac arteries with reference vessel diameters ranging from 5 to 13 mm and lesion lengths ≤ 110 mm, including lesions at the aortic bifurcation and for use with thoracoabdominal and pararenal branched devices indicated with the VBX Device as a branch component |
Stents / Self-Expanding Stent Grafts
View Chart| Company Name | Product Name | Materials Used | Introducer Size (F) | Guidewire Compatibility (inch) | Stent Diameter (mm) | Stent Length (mm) | Delivery System Length (cm) | US FDA Indicated Use | Comments |
|---|---|---|---|---|---|---|---|---|---|
| Gore & Associates | Gore Viatorr TIPS Endoprosthesis with Controlled Expansion | Nitinol/ePTFE | 10 | 0.035 | 8-10 | 60, 70, 80, 90, 100 | 75 | Indicated for use in de novo and revision treatment of portal hypertension and its complications such as variceal bleeding, gastropathy, ascites, and/or hepatic hydrothorax | TIPS, transjugular intrahepatic portosystemic shunt |
| Gore & Associates | Gore Viabil Biliary Endoprosthesis | Nitinol/ePTFE | 10 (percutaneous) | 0.035 | 8, 10 | 40, 60, 80, 100 | 40 (percutaneous) | Malignant biliary strictures* | *Contraindicated for all cardiovascular applications |
| Gore & Associates | Gore Viabahn Endoprosthesis With Heparin Bioactive Surface | Nitinol/ePTFE, gold | 6–10 | 0.018/0.014 (5–8 mm), 0.035 (5–13 mm) | 5, 6, 7, 8, 9, 10, 11, 13 | 25, 50, 75, 100, 150, 250 | 75 (0.035-inch system only), 120 | 5–8 mm indicated for symptomatic PAD lesions in the SFA up to 270 mm in length reference vessel diameters ranging from 4.0 to 7.5 mm; 5–7 mm indicated for symptomatic in-stent restenosis lesions in the SFA up to 270 mm in length with reference vessel diameters ranging from 4.0 to 6.5 mm; 5–13 mm indicated for symptomatic PAD lesions in the iliac artery up to 80 mm in length with reference vessel diameters ranging from 4.0 to 12 mm; also indicated for stenosis or thrombotic occlusion at venous anastomosis of synthetic AV access grafts | – |
| Gore & Associates | Gore Viabahn Endoprosthesis | Nitinol/ePTFE, gold | 7–10 | 0.035 | 5, 6, 7, 8, 9, 10, 11, 13 | 25, 50, 75, 100, 150, 250 | 75, 120 | 5–8 mm indicated for symptomatic PAD lesions in the SFA up to 270 mm in length reference vessel diameters ranging from 4.0 to 7.5 mm; 5–7 mm indicated for symptomatic in-stent restenosis lesions in the SFA up to 270 mm in length with reference vessel diameters ranging from 4.0 to 6.5 mm; 5–13 mm indicated for symptomatic PAD lesions in the iliac artery up to 80 mm in length with reference vessel diameters ranging from 4.0 to 12 mm; also indicated for stenosis or thrombotic occlusion at venous anastomosis of synthetic AV access grafts | – |
Aortic (AAA) / Occlusion/Molding Balloons
View Chart| Company Name | Product Name | Size (F) | Recommended Introducer Size (F) | Guidewire Compatibility (inch) | Catheter Length (cm) | Maximum Inflated Balloon Diameter (mm) |
|---|---|---|---|---|---|---|
| Gore & Associates | Gore Molding & Occlusion Balloon | 10 | 10 | 0.035 | 90 | 37 |
Aortic (AAA) / Other Accessories
View Chart| Company Name | Product Name | Size (F) | Guidewire Compatibility (inch) | Comments |
|---|---|---|---|---|
| Gore & Associates | Gore Tri-Lobe Balloon Catheter | 18 | 0.035 | Unique design allows for continuous blood flow |
| Gore & Associates | Gore DrySeal Flex Introducer Sheath | 10, 12, 14, 15, 16, 18, 20, 22, 24, 26 | 0.035 | A new standard of flexibility to treat more challenging anatomies |
Aortic (TAA) / Thoracic Stent Grafts
View Chart| Company Name | Product Name | Stent Material | Graft Material | Stent Expansion | Length (cm) | Diameter (mm) | Sheath Required for Delivery | Sheath Compatibility (F) |
|---|---|---|---|---|---|---|---|---|
| Gore & Associates | Gore TAG Thoracic Branch Endoprosthesis - Side Branch | Nitinol | ePTFE | Self expanding | 6 | 8, 10, 12, 15, 17 for 8-mm portal Gore TAG Thoracic Branch Endoprosthesis Aortic component; 15, 17, 20 for 12-mm portal Gore TAG Thoracic Branch Endoprosthesis Aortic component | Yes (to be delivered through the same sheath used for Gore TAG Thoracic Branch Endoprosthesis Aortic component) | 14 (ID) |
| Gore & Associates | Gore TAG Thoracic Branch Endoprosthesis - Aortic Extender | Nitinol | ePTFE | Self expanding | 3.6–4.6 depending on device diameter | 21, 26, 28, 31, 34, 37, 40, 45 | Yes (to be delivered through the same sheath used for Gore TAG Thoracic Branch Endoprosthesis Aortic component) | 20, 22, 24, 26 (ID) |
| Gore & Associates | Gore TAG Thoracic Branch Endoprosthesis - Aortic Component | Nitinol | ePTFE | Self expanding | 10, 15, 20 | 21, 26, 28, 31, 34, 37, 40, 45 with 8-mm or 12-mm internal portal for Gore TAG Thoracic Branch Endoprosthesis Side Branch component | Yes | 20, 22, 24, 26 (ID) |
| Gore & Associates | Gore TAG Conformable Thoracic Stent Graft With Active Control System | Nitinol | ePTFE | Self expanding | 10, 15, 20 | 21, 26, 28, 31, 34, 37, 40, 45; tapered: 26 X 21, 31 X 26 | Yes | 18, 20, 22, 24 (ID) |
Aortic (TAA) / Occlusion/Molding Balloons
View Chart| Company Name | Product Name | Size (F) | Recommended Introducer Size (F) | Guidewire Compatibility (inch) | Catheter Length (cm) | Maximum Inflated Balloon Diameter (mm) |
|---|---|---|---|---|---|---|
| Gore & Associates | Gore Tri-Lobe Balloon Catheter | 18 | 18 | 0.035 | 104 | 32, 42 |
Aortic (TAA) / Other Accessories
View Chart| Company Name | Product Name | Size (F) | Guidewire Compatibility (inch) | Comments |
|---|---|---|---|---|
| Gore & Associates | Gore DrySeal Flex Introducer Sheath | 10, 12, 14, 15, 16, 18, 20, 22, 24, 26 | 0.035 | A new standard of flexibility to treat more challenging anatomies |
More Categories: