Other Devices / Mechanical Thrombectomy/Thrombolysis (Peripheral/Venous)
View Chart| Company Name | Product Name | Sheath Compatibility (F) | Guidewire Compatibility (inch) | Working Length (cm) | Mode of Operation | CE Mark Indications |
|---|---|---|---|---|---|---|
| Inari Medical | ClotTriever Thrombectomy System | 13, 16 | 0.035 | 80 | Mechanical coring, collection, and retrieval of emboli and thrombi | The nonsurgical removal of thrombi and emboli from blood vessels; injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel; intended for use in the peripheral vasculature including deep vein thrombosis |
| Inari Medical | FlowTriever Catheter (disks) - FlowTriever Retrieval/Aspiration System | 20, 22 | 0.035 | 115 | Mechanical and aspirational disruption, fragmentation, maceration, and retrieval of emboli and thrombi | The nonsurgical removal of emboli and thrombi from blood vessels, and injection, infusion and/or aspiration of contrast media and other fluids into or from a blood vessel; the FlowTriever System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism; Triever catheters are intended for use in treating clot in transit in the right atrium, but not in conjunction with FlowTriever catheters |
| Inari Medical | FlowTriever2 Catheter (disks) - FlowTriever Retrieval/Aspiration System | 20, 22, 24, 26 | 0.035 | 120 | Mechanical and aspirational disruption, fragmentation, maceration, and retrieval of emboli and thrombi | The nonsurgical removal of emboli and thrombi from blood vessels, and injection, infusion and/or aspiration of contrast media and other fluids into or from a blood vessel; FlowTriever2 is intended for use in the peripheral vasculature |
| Inari Medical | Triever16 - FlowTriever Retrieval/Aspiration System | 20, 22, 24 | 0.035 | 113 | Mechanical and aspirational disruption, fragmentation, maceration, and retrieval of emboli and thrombi | The nonsurgical removal of emboli and thrombi from blood vessels, and injection, infusion and/or aspiration of contrast media and other fluids into or from a blood vessel; the FlowTriever System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism; Triever catheters are intended for use in treating clot in transit in the right atrium, but not in conjunction with FlowTriever catheters |
| Inari Medical | Triever20 - FlowTriever Retrieval/Aspiration System | 20, 22, 24 | 0.035 | 90 | Mechanical and aspirational disruption, fragmentation, maceration, and retrieval of emboli and thrombi | The nonsurgical removal of emboli and thrombi from blood vessels, and injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel; the FlowTriever System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism; Triever catheters are intended for use in treating clot in transit in the right atrium but not in conjunction with FlowTriever catheters |
| Inari Medical | Triever24 - FlowTriever Retrieval/Aspiration System | 24, 26 | 0.035 | 90 | Mechanical and aspirational disruption, fragmentation, maceration, and retrieval of emboli and thrombi | The nonsurgical removal of emboli and thrombi from blood vessels, and injection, infusion and/or aspiration of contrast media and other fluids into or from a blood vessel; the FlowTriever System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism; Triever Catheters are intended for use in treating clot in transit in the right atrium, but not in conjunction with FlowTriever catheters |
More Categories:
Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View AllAdvertisement