The cannula is indicated for the nonsurgical removal of thrombi or emboli from the pulmonary arteries; aspiration of contrast media and other fluids from the pulmonary arteries; the cannula is intended for the treatment of pulmonary embolism
The handle is indicated as a vacuum source for the AlphaVac Multipurpose Mechanical Aspiration System
Boston Scientific Corporation
AngioJet AVX Thrombectomy Set
6
0.035
50
High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal
Breaking apart and removing thrombus from AV access conduits ≥ 3 mm in diameter
Boston Scientific Corporation
AngioJet Distaflex Thrombectomy Set
4
0.014
145
High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal
Removing thrombus in the treatment of patients with symptomatic coronary artery or saphenous vein graft lesions prior to balloon angioplasty or stent placement and use in breaking apart and removing thrombus from infrainguinal peripheral arteries ≥ 2 mm in diameter
Boston Scientific Corporation
AngioJet Solent Dista Thrombectomy Set
4
0.014
145
High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal (PowerPulse enabled)
Breaking apart and removing thrombus from upper and lower extremity peripheral arteries ≥ 1.5 mm in diameter
Boston Scientific Corporation
AngioJet Solent Omni Thrombectomy Set
6
0.035
120
High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal (PowerPulse enabled)
Breaking apart and removing thrombus from upper and lower extremity peripheral arteries, upper extremity peripheral veins, iliofemoral and lower extremity veins, and AV access conduits ≥ 3 mm in diameter
Boston Scientific Corporation
AngioJet Solent Proxi Thrombectomy Set
6
0.035
90
High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal (PowerPulse enabled)
Breaking apart and removing thrombus from upper and lower extremity peripheral arteries, upper extremity peripheral veins, iliofemoral and lower extremity veins, and AV access conduits ≥ 3 mm in diameter
Boston Scientific Corporation
AngioJet Spiroflex Thrombectomy Set
5
0.014
135
High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal
Removing thrombus in the treatment of patients with symptomatic coronary artery or saphenous vein graft lesions prior to balloon angioplasty or stent placement and use in breaking apart and removing thrombus from infrainguinal peripheral arteries ≥ 2 mm in diameter
Boston Scientific Corporation
AngioJet SpiroflexVG Thrombectomy Set
6
0.014
135
High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal
Removing thrombus in the treatment of patients with symptomatic coronary artery or saphenous vein graft lesions prior to balloon angioplasty or stent placement and use in breaking apart and removing thrombus from infrainguinal peripheral arteries ≥ 3 mm in diameter
Boston Scientific Corporation
AngioJet Ultra PE Thrombectomy Set
6
0.035
120
High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal
Breaking apart and removing thrombus from main pulmonary and lobar arteries ≥ 6 mm in diameter
Boston Scientific Corporation
AngioJet XMI Thrombectomy Set
4
0.014
135
High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal
Removing thrombus in the treatment of patients with symptomatic coronary artery or saphenous vein graft lesions prior to balloon angioplasty or stent placement and use in breaking apart and removing thrombus from infrainguinal peripheral arteries ≥ 2 mm in diameter
Boston Scientific Corporation
AngioJet ZelanteDVT Thrombectomy Set
8
0.035
105
High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal (PowerPulse enabled)
Intended for use with the AngioJetUltra Console to break apart and remove thrombus, including DVT, from: Iliofemoral and lower extremity veins ≥ 6 mm in diameter and upper extremity peripheral veins ≥ 6 mm in diameter; also intended for use with the AngioJet Ultra Power Pulse technique for the controlled and selective infusion of physician specified fluids, including thrombolytic agents, into the peripheral vascular system
BD Interventional
AspirexS: Mechanical Aspiration Thrombectomy System
8
0.018
85, 110
Aspirex S catheters in combination with the Straub Medical Drive System (REF SRS-Set/80300) are intended for the percutaneous transluminal removal of fresh thrombotic or thromboembolic material from blood vessels outside the cardiopulmonary, coronary, and cerebral circulations
Native blood vessels or vessels fitted with stents, stent grafts, or native or artificial bypasses outside the cardiopulmonary, coronary, and cerebral circulations
BD Interventional
AspirexS: Mechanical Aspiration Thrombectomy System
10
0.025
110
Aspirex S catheters in combination with the Straub Medical Drive System (REF SRS-Set/80300) are intended for the percutaneous transluminal removal of fresh thrombotic or thromboembolic material from blood vessels outside the cardiopulmonary, coronary, and cerebral circulations
Native blood vessels or vessels fitted with stents, stent grafts, or native or artificial bypasses outside the cardiopulmonary, coronary, and cerebral circulations
BD Interventional
AspirexS: Mechanical Aspiration Thrombectomy System
6
0.018
110, 135
Aspirex S catheters in combination with the Straub Medical Drive System (REF SRS-Set/80300) are intended for the percutaneous transluminal removal of fresh thrombotic or thromboembolic material from blood vessels outside the cardiopulmonary, coronary, and cerebral circulations
Native blood vessels or vessels fitted with stents, stent grafts, or native or artificial bypasses outside the cardiopulmonary, coronary, and cerebral circulations
Argon Medical Devices, Inc.
Cleaner 15
7
–
65, 135
Battery-operated, handheld drive unit initiates the mechanical rotation of an atraumatic, wall-contacting, 15-mm sinusoidal vortex wire for effective thrombus maceration
Indicated for mechanical declotting and controlled and selective infusion of physician-specified fluids, including thrombolytics, in the peripheral vasculature; also indicated for mechanical declotting of native vessel dialysis fistulas and synthetic dialysis access grafts
Argon Medical Devices, Inc.
Cleaner XT
6
–
65, 135
Battery-operated, handheld drive unit initiates the mechanical rotation of an atraumatic, wall-contacting, 9-mm sinusoidal vortex wire for effective thrombus maceration
Indicated for mechanical declotting and controlled and selective infusion of physician-specified fluids, including thrombolytics, in the peripheral vasculature; also indicated for mechanical declotting of native vessel dialysis fistulas and synthetic dialysis access grafts
Inari Medical
ClotTriever Thrombectomy System
13, 16
0.035
80
Mechanical coring, collection, and retrieval of emboli and thrombi
The nonsurgical removal of thrombi and emboli from blood vessels; injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel; intended for use in the peripheral vasculature including deep vein thrombosis
Control Medical Technology
Control 10F Mechanical Thrombectomy System
10
0.035
90
Mechanical thrombectomy with mechanical aspirator, OTW catheter, and dilator
Mechanical thrombectomy to remove soft fresh emboli and thrombi from the peripheral vasculature
Control Medical Technology
Control 5F Mechanical Thrombectomy System
5
0.035
135
Mechanical thrombectomy
Mechanical thrombectomy to remove soft fresh emboli and thrombi from the peripheral vasculature
Control Medical Technology
Control 6F Mechanical Thrombectomy System
6
0.035
135
Mechanical thrombectomy
Mechanical thrombectomy to remove soft fresh emboli and thrombi from the peripheral vasculature
Control Medical Technology
Control 8F Mechanical Thrombectomy System
8
0.035
90
Mechanical thrombectomy with mechanical aspirator, OTW catheter, and dilator
Mechanical thrombectomy to remove soft fresh emboli and thrombi from the peripheral vasculature
Control Medical Technology
Control Mechanical Aspirator
Any sheath
Any guidewire
Any length
Mechanical aspirator
Mechanical thrombectomy and to remove fluids from the body
The treatment offers a minimally invasive system for the acceleration of thrombus dissolution; the ultrasonic core generates a localized acoustic field that targets the entire thrombus; this greatly accelerates lytic dispersion by driving the drug deeper into the clot and unwinding the fibrin to expose plasminogen receptor sites
Intended for controlled and selective infusion of physician-specified fluids, including thrombolytics, into the peripheral vasculature; for the treatment of pulmonary embolism with a ≥ 50% clot burden in one or both main pulmonary arteries or lobar pulmonary arteries, and evidence of right heart dysfunction based on right heart pressures (mean pulmonary artery pressure ≥ 25 mm Hg) or echocardiographic evaluation
Inari Medical
FlowTriever Catheter (disks) - FlowTriever Retrieval/Aspiration System
20, 22
0.035
115
Mechanical and aspirational disruption, fragmentation, maceration, and retrieval of emboli and thrombi
The nonsurgical removal of emboli and thrombi from blood vessels, and injection, infusion and/or aspiration of contrast media and other fluids into or from a blood vessel; the FlowTriever System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism; Triever catheters are intended for use in treating clot in transit in the right atrium, but not in conjunction with FlowTriever catheters
Inari Medical
FlowTriever2 Catheter (disks) - FlowTriever Retrieval/Aspiration System
20, 22, 24, 26
0.035
120
Mechanical and aspirational disruption, fragmentation, maceration, and retrieval of emboli and thrombi
The nonsurgical removal of emboli and thrombi from blood vessels, and injection, infusion and/or aspiration of contrast media and other fluids into or from a blood vessel; FlowTriever2 is intended for use in the peripheral vasculature
Penumbra, Inc. (Peripheral Vascular)
Indigo System Catheter, Lightning 12, Lightning 7, CAT7D, CAT8, CATD, CAT6, CAT5, and CAT3
The Indigo System with Lightning Aspiration Tubing is computer aided mechanical aspiration powered by the Penumbra ENGINE which utilizes a unique mechanism of action to help optimize thrombus removal procedures by differentiating between thrombus and blood. Lightning comes packaged as Lightning 7 and Lightning 12
As part of the Indigo Aspiration System, the Indigo aspiration catheters and separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems, and for the treatment of pulmonary embolism
Penumbra, Inc. (Peripheral Vascular)
Indigo System Catheters: Lightning Bolt 7
7
0.014–0.038
130
Lightning Bolt Aspiration Tubing is designed to serve as a conduit to assist in thrombus removal, facilitating transfer of vacuum between the Penumbra Aspiration Pump and the INDIGO Aspiration Catheter while providing intermittent, continuous, or modulated aspiration; modulated aspiration is provided when the Lightning Bolt Aspiration Tubing alternates between connecting the INDIGO Aspiration Catheter to the Penumbra Aspiration Pump and a sterile saline intravenous (IV) bag at ambient pressure
The Indigo Aspiration Catheters and Separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems and for the treatment of pulmonary embolism. As part of the INDIGO Aspiration System, the INDIGO Sterile Aspiration Tubing is indicated to connect the INDIGO Aspiration Catheters to the Penumbra Aspiration Pump.
Penumbra, Inc. (Peripheral Vascular)
Indigo System Separator, SEP12, SEP7, SEP7D, SEP8, SEPD, SEP6, SEP5, and SEP3
–
–
90–190
The device is advanced and retracted through the Indigo catheter at the proximal margin of the primary occlusion to facilitate clearing of the thrombus from the catheter tip, as needed
As part of the Indigo Aspiration System, the Indigo aspiration catheters and separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems, and for the treatment of pulmonary embolism
Invamed
Mantis
7
–
90
Battery-operated, handheld drive unit initiates the mechanical rotation of an atraumatic unique loop shape with aspiration
DVT pharmacomechanical declotting and controlled and selective infusion of physician-specified fluids, including thrombolytics, in the peripheral vasculature; double engine volume, low and high speed options; hydrophilic tip
BD Interventional
RotarexS Rotational Atherothrombectomy System
10
0.025
85
RotarexS catheters in combination with the Straub Medical Drive System (REF SRS-Set/80300) are intended for the percutaneous transluminal removal of thrombotic, thromboembolic and atherothrombotic material from fresh, subacute and chronic occlusions of blood vessels outside the cardiopulmonary, coronary and cerebral circulations
Native blood vessels or vessels fitted with stents, stent grafts or native or artificial bypasses outside the cardiopulmonary, coronary and cerebral circulations
BD Interventional
RotarexS Rotational Atherothrombectomy System
8
0.018
85, 110
RotarexS catheters in combination with the Straub Medical Drive System (REF SRS-Set/80300) are intended for the percutaneous transluminal removal of thrombotic, thromboembolic and atherothrombotic material from fresh, subacute and chronic occlusions of blood vessels outside the cardiopulmonary, coronary and cerebral circulations
Native blood vessels or vessels fitted with stents, stent grafts or native or artificial bypasses outside the cardiopulmonary, coronary and cerebral circulations
BD Interventional
RotarexS Rotational Atherothrombectomy System
6
0.018
110, 135
RotarexS catheters in combination with the Straub Medical Drive System (REF SRS-Set/80300) are intended for the percutaneous transluminal removal of thrombotic, thromboembolic and atherothrombotic material from fresh, subacute and chronic occlusions of blood vessels outside the cardiopulmonary, coronary and cerebral circulations
Native blood vessels or vessels fitted with stents, stent grafts or native or artificial bypasses outside the cardiopulmonary, coronary and cerebral circulations
Inari Medical
Triever16 - FlowTriever Retrieval/Aspiration System
20, 22, 24
0.035
113
Mechanical and aspirational disruption, fragmentation, maceration, and retrieval of emboli and thrombi
The nonsurgical removal of emboli and thrombi from blood vessels, and injection, infusion and/or aspiration of contrast media and other fluids into or from a blood vessel; the FlowTriever System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism; Triever catheters are intended for use in treating clot in transit in the right atrium, but not in conjunction with FlowTriever catheters
Inari Medical
Triever20 - FlowTriever Retrieval/Aspiration System
20, 22, 24
0.035
90
Mechanical and aspirational disruption, fragmentation, maceration, and retrieval of emboli and thrombi
The nonsurgical removal of emboli and thrombi from blood vessels, and injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel; the FlowTriever System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism; Triever catheters are intended for use in treating clot in transit in the right atrium but not in conjunction with FlowTriever catheters
Inari Medical
Triever24 - FlowTriever Retrieval/Aspiration System
24, 26
0.035
90
Mechanical and aspirational disruption, fragmentation, maceration, and retrieval of emboli and thrombi
The nonsurgical removal of emboli and thrombi from blood vessels, and injection, infusion and/or aspiration of contrast media and other fluids into or from a blood vessel; the FlowTriever System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism; Triever Catheters are intended for use in treating clot in transit in the right atrium, but not in conjunction with FlowTriever catheters
Invamed
Viper
5
0.035
200
Designed for controlled infusion of tPA along with mechanical vibrations
Over the guidewire system and 200 cm catheter length allows safe access to closed target vessels including pulmonary artery in PE cases
Advertisement
Advertisement
We value keeping the Device Guide up to date.
If you want to add or update your company’s device listings, please let us know!