Indicated for use as a guidewire and EPS to contain and remove embolic material (thrombus/debris) while performing carotid artery angioplasty and stenting procedures in carotid arteries; the diameter of the artery at the site of the filter basket placement should be from 3 to 7.5 mm (see instructions for use for basket/vessel sizing)
Abbott
Emboshield Nav6
Barewire filter delivery wire
Distal
The system is designed to reduce distal embolization while maintaining blood flow during interventional procedures; indicated for use during percutaneous transluminal angioplasty, and stenting procedures in saphenous vein grafts and carotid arteries and percutaneous transluminal angioplasty, atherectomy and stenting procedures in the lower extremity arteries
Boston Scientific Corporation
FilterWire EZ Embolic Protection System
Filter
Distal
Indicated for use as a guidewire and EPS to contain and remove embolic material (thrombus/debris) while performing angioplasty and stenting procedures in coronary saphenous vein bypass grafts and carotid arteries; the diameter of the vessel at the site of filter loop placement should be between 2.25–5.5 mm for coronary saphenous vein bypass graft procedures and between 3.5–5.5 mm for carotid procedures
Invamed
Inca
Protective filter
Distal
Indicated for use as a guidewire and EPS to contain and remove embolic material while performing DVT carotid artery angioplasty, stenting procedures in carotid arteries; suitable for acute PE, VTE, and ICU thrombectomy
Medtronic
Mo.Ma Ultra Proximal Cerebral Protection Device
Proximal protection
Proximal
Indicated as an EPS to contain and remove embolic material (thrombus/debris) while performing angioplasty and stenting procedures involving lesions of the internal carotid artery and/or the bifurcation; the reference diameter of the external carotid artery should be between 3–6 mm and the reference diameter of the common carotid artery should be between 5–13 mm
Terumo Europe
Nanoparasol
Filter; concentric nitinol micromesh; guidewire of choice
Distal
Indicated for use in patients with carotid arterial atherosclerotic disease; indicated for use as a guidewire to contain and remove embolic material (thrombus/debris) while performing angioplasty and stenting procedures in carotid arteries
Contego Medical LLC
Paladin Carotid Post-Dilation Balloon System With Integrated Embolic Protection
Carotid postdilation balloon with integrated embolic protection filter (40 µm)
Distal
Indicated for postdilation of a deployed self-expanding stent in the carotid artery
Balton
Robin RX/OTW
Nitinol filter basket
Distal
Distal neuroprotection system is used to seize embolic material during performance of angioplasty procedure on carotid artery and during stent implementation in carotid arteries; recommended vessel diameter from 3 to 7.5 mm
Utilizes an embolic filter delivered to the brachiocephalic artery (proximal filter) and a second embolic filter delivered to the left common carotid artery (distal filter)
Indicated for use as an embolic protection device to capture and remove embolic material (thrombus/debris) that may enter the cerebral vascular system during endovascular procedures; the diameters of the arteries at the site of filter placement should be between 9–15 mm for the brachiocephalic and 6.5–10 mm in the left common carotid
Medtronic
SpiderFX Embolic Protection Device
Filter; guidewire of choice
Distal
Indicated for distal embolization protection during peripheral, coronary, and carotid interventions; indications, contraindications, warnings, and Instructions for Use can be found in the product labeling supplied with each device
Contego Medical LLC
Vanguard IEP Peripheral Balloon Angioplasty System With Integrated Embolic Protection
Angioplasty balloon with integrated embolic protection filter (150 µm)
Distal
Indicated for peripheral vascular percutaneous transluminal angioplasty and the capture and removal of embolic material during angioplasty for the femoral, iliac, popliteal, and profunda arteries