Group 7 Copy 3 Created with Sketch.
News Issue Archive Device Guide Calendar Subscribe Advertising

MENU

Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

News Current Issue Archive Device Guide Calendar Subscribe Advertising About Contact Privacy Submissions
Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

Back to Top

Advertisement

Advertisement

EUROPE. Company Directory


Reflow Medical, Inc

208 Avenida Fabricante, Suite 100, San Clemente, CA 92673

PHONE: (949) 481-0399

down-arrow Created with Sketch.
down-arrow Created with Sketch.

Catheters / Angiographic Catheters: Selective, Hydrophilic Coated

View Chart
Company Name Product Name Type Size (F) Length (cm) Guidewire Compatibility (inch) Radiopaque Tip (Yes/No) Variety of Selective Shapes
Reflow Medical, Inc SpexLP 14 Shapeable Support Microcatheter Low profile, shapeable tip, braid reinforced 2.2 90, 135, 150 0.014 Yes User's choice
Reflow Medical, Inc SpexLP 18 Shapeable Support Microcatheter Low profile, shapeable tip, braid reinforced 2.5 90, 135, 150 0.018 Yes User's choice
Reflow Medical, Inc SpexLP 35 Shapeable Support Microcatheter Low profile, shapeable tip, braid reinforced 3.8 90, 135, 150 0.035 Yes User's choice
Reflow Medical, Inc Spex35 Shapeable Support Microcatheter Shapeable tip, braid reinforced 4.6 50, 90, 135, 150 0.035 Yes User's choice

Advertisement

Advertisement

Catheters / Microcatheters

View Chart
Company Name Product Name Type of Catheter Construction Proximal Size (F) Middle Size (F) Distal Size (F) Catheter Working Length (cm) Catheter Endhole Diameter ID (inch) Recommended Guidewire Size (inch) Radiopaque Tip (Yes/No) Hydrophilic Coating (Yes/No)
Reflow Medical, Inc Wingman14 CTO Crossing Catheter Braided with extendable beveled tip 2.7 2.7 2.7 65, 135, 150 0.022 0.014 Yes No
Reflow Medical, Inc Wingman18 CTO Crossing Catheter Braided with extendable beveled tip 3.8 3.8 3.8 90, 135, 150 0.032 0.018 Yes Yes
Reflow Medical, Inc Spex35 Shapeable Support Microcatheter Shapeable tip, braid reinforced 4.6 4.6 4.6 50, 90, 135, 150 0.038 0.035 Yes Yes
Reflow Medical, Inc SpexLP 14 Shapeable Support Microcatheter Low profile, shapeable tip, braid reinforced 2.2 2.2 1.4 90, 135, 150 0.018 0.014 Yes Yes
Reflow Medical, Inc SpexLP 18 Shapeable Support Microcatheter Low profile, shapeable tip, braid reinforced 2.5 2.5 1.6 90, 135, 150 0.021 0.018 Yes Yes
Reflow Medical, Inc SpexLP 35 Shapeable Support Microcatheter Low profile, shapeable tip, braid reinforced 3.8 3.8 2.9 90, 135, 150 0.038 0.035 Yes Yes
Reflow Medical, Inc Wingman 14C CTO Crossing Catheter Braided with extendable beveled tip 2.7 2.7 2.7 90, 135, 150 0.024 0.014 Yes Yes
Reflow Medical, Inc Wingman 35 CTO Crossing Catheter Braided with extendable beveled tip 4.6 4.6 4.6 90, 135, 150 0.032 0.035 Yes Yes

Catheters / Specialty Catheters

View Chart
Company Name Product Name Catheter Size (F) Working Length (cm) Minimum Guiding Catheter ID (inch) Comments
Reflow Medical, Inc Spex35 Shapeable Support Microcatheter 4.6 50, 90, 135, 150 0.066 Single lumen, shapeable tip microcatheters designed to access the peripheral vasculature; allows for exchange of guidewires and other interventional devices and provides a conduit for delivery of saline solutions or diagnostic contrast; available in a variety of lengths; braided support matrix and hydrophilic coating (distal segment); the distal tip of the Spex has one radiopaque marker
Reflow Medical, Inc Wingman 14C CTO Crossing Catheter 2.7 90, 135, 150 0.039 A beveled (needle) tip recanalization device intended to provide additional support to a steerable guidewire when accessing discrete regions of the peripheral vasculature; the Wingman CTO Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable needle tip) and activating handle
Reflow Medical, Inc SpexLP 35 Shapeable Support Microcatheter 3.8 90, 135, 150 0.052 Single lumen, shapeable tip microcatheters designed to access the peripheral vasculature; allows for exchange of guidewires and other interventional devices and provides a conduit for delivery of saline solutions or diagnostic contrast; available in a variety of lengths and diameters; braided support matrix and hydrophilic coating (distal segment); Spex LP has 3 radiopaque markers spaced equally along the distal shaft at 50-mm increments, to aid in estimating geometry within the vascular system
Reflow Medical, Inc SpexLP 18 Shapeable Support Microcatheter 2.5 90, 135, 150 0.021 Single lumen, shapeable tip microcatheters designed to access the peripheral vasculature; allows for exchange of guidewires and other interventional devices and provides a conduit for delivery of saline solutions or diagnostic contrast; available in a variety of lengths and diameters; braided support matrix and hydrophilic coating (distal segment); Spex LP has 3 radiopaque markers spaced equally along the distal shaft at 50-mm increments, to aid in estimating geometry within the vascular system
Reflow Medical, Inc SpexLP 14 Shapeable Support Microcatheter 2.2 90, 135, 150 0.052 Single lumen, shapeable tip microcatheters designed to access the peripheral vasculature; allows for exchange of guidewires and other interventional devices and provides a conduit for delivery of saline solutions or diagnostic contrast; available in a variety of lengths and diameters; braided support matrix and hydrophilic coating (distal segment); Spex LP has 3 radiopaque markers spaced equally along the distal shaft at 50-mm increments, to aid in estimating geometry within the vascular system
Reflow Medical, Inc Wingman35 CTO Crossing Catheter 4.6 65, 90, 135 0.066 A beveled (needle) tip recanalization device intended to provide additional support to a steerable guidewire when accessing discrete regions of the peripheral vasculature; the Wingman CTO Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable needle tip) and activating handle
Reflow Medical, Inc Wingman18 CTO Crossing Catheter 3.8 90, 135, 150 0.052 A beveled (needle) tip recanalization device intended to provide additional support to a steerable guidewire when accessing discrete regions of the peripheral vasculature; the Wingman CTO Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable needle tip) and activating handle
Reflow Medical, Inc Wingman14 CTO Crossing Catheter 2.7 65, 135, 150 0.039 A beveled (needle) tip recanalization device intended to provide additional support to a steerable guidewire when accessing discrete regions of the peripheral vasculature; the Wingman CTO Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable needle tip) and activating handle

Other Devices / CTO Crossing Devices

View Chart
Company Name Product Name Catheter Size (F) Wire Size (inch) Working Length (cm) Minimum Guiding Catheter ID (inch) Comments
Reflow Medical, Inc Wingman14 CTO Crossing Catheter 2.7 0.014 65, 135, 150 0.039 A beveled (needle) tip recanalization device intended to provide additional support to a steerable guidewire when accessing discrete regions of the peripheral vasculature; the Wingman CTO Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable needle tip) and activating handle
Reflow Medical, Inc Wingman18 CTO Crossing Catheter 3.8 0.018 90, 135, 150 0.052 A beveled (needle) tip recanalization device intended to provide additional support to a steerable guidewire when accessing discrete regions of the peripheral vasculature; the Wingman CTO Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable needle tip) and activating handle
Reflow Medical, Inc Wingman35 CTO Crossing Catheter 4.6 0.035 65, 90, 135 0.066 A beveled (needle) tip recanalization device intended to provide additional support to a steerable guidewire when accessing discrete regions of the peripheral vasculature; the Wingman CTO Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable needle tip) and activating handle
Reflow Medical, Inc Wingman 14C CTO Crossing Catheter 2.7 0.014 90, 135, 150 0.039 A beveled (needle) tip recanalization device intended to provide additional support to a steerable guidewire when accessing discrete regions of the peripheral vasculature; the Wingman CTO Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable needle tip) and activating handle

Other Devices / Retrievable Scaffold Therapy

View Chart
Company Name Product Name Material Used Introducer Size (F) Guidewire Compatibility (inch) Device Diameter (mm) Device Length (mm) Delivery System Length (cm) CE Mark Indications
Reflow Medical, Inc Spur Nitinol 6 0.014 3, 4 60, 65 135 Indicated for treatment of de novo or restenotic infrapopliteal lesions, with a reference vessel diameters ranging from 2.5 to 4.5 mm, prior to treatment with a commercially available drug-coated balloon; intended to treat de novo or restenotic lesions in the infrapopliteal arteries to prepare the vessel for treatment with a commercially available drug-coated balloon to enhance drug absorption

More Categories:

Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View All

Advertisement

Latest News


April 17, 2026

Bayer’s Asundexian FXIa Inhibitor Demonstrates Reduction in Ischemic Stroke in OCEANIC-STROKE Study

April 16, 2026

Rapid Medical’s Tigertriever 25 Cleared by FDA to Treat LVO Stroke

April 15, 2026

Stereotaxis to Acquire Robocath

Most Read Articles


A Private Practice Physician’s Experience Treating Chronic Venous Insufficiency

By Robert A. Edwards, DO

Update on Modern Complex Abdominal Aortic Repair Options

With Jason T. Lee, MD; Steven Maximus, MD, FACS; Gustavo Oderich, MD, FACS; Benjamin W. Starnes, MD, FACS; Carlos Timaran, MD; Kak Khee Yeung, MD, PhD, FEBVS; and Javairiah Fatima, MD, FACS, DFSVS

Transforming the Future of PE Care: Expanding Mechanical Thrombectomy Through Innovation

By Mehdi Shishehbor, DO, MPH, PhD

Back to Top
Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous
Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

News• Current Issue• Archive• Device Guide• Advertising• About Calendar• Contact• Privacy• Submissions• Subscriptions


Endovascular Today (ISSN 1551-1944 print and ISSN 2689-792X online) is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field.



magazine Created with Sketch.

Free Print Subscriptions

Fill 1 Created with Sketch.

Email Newsletter



twitter-icon LinkedIn Created with Sketch. instagram BlueSky-Circle
Cardiac Interventions Today
Group 7 Copy 3 Created with Sketch.
bmc-secondary-mark-color copy Created with Sketch.

© 2026 Bryn Mawr Communications II, LLC.  
All Rights Reserved   •   Privacy Policy

one-trust-button