Advertisement
Advertisement
Reflow Medical, Inc
208 Avenida Fabricante, Suite 100, San Clemente, CA 92673
PHONE: (949) 481-0399
Catheters / Specialty Catheters
View Chart| Company Name | Product Name | Catheter Size (F) | Working Length (cm) | Minimum Guiding Catheter ID (inch) | Comments |
|---|---|---|---|---|---|
| Reflow Medical, Inc | SpexLP 14 Shapeable Support Microcatheter | 2.2 | 90, 135, 150 | 0.052 | Single lumen, shapeable tip support catheter designed to access the peripheral vasculature; allows for exchange of guidewires and other interventional devices and provides a conduit for delivery of saline solutions or diagnostic contrast; available in a variety of lengths and diameters; braided support matrix and hydrophilic coating (distal segment); Spex LP has 3 radiopaque markers spaced equally along the distal shaft at 50-mm increments, to aid in estimating geometry within the vascular system |
| Reflow Medical, Inc | SpexLP 18 Shapeable Support Microcatheter | 2.5 | 90, 135, 150 | 0.052 | Single lumen, shapeable tip support catheter designed to access the peripheral vasculature; allows for exchange of guidewires and other interventional devices and provides a conduit for delivery of saline solutions or diagnostic contrast; available in a variety of lengths and diameters; braided support matrix and hydrophilic coating (distal segment); Spex LP has 3 radiopaque markers spaced equally along the distal shaft at 50-mm increments, to aid in estimating geometry within the vascular system |
| Reflow Medical, Inc | SpexLP 35 Shapeable Support Microcatheter | 3.8 | 90, 135, 150 | 0.052 | Single lumen, shapeable tip support catheter designed to access the peripheral vasculature; allows for exchange of guidewires and other interventional devices and provides a conduit for delivery of saline solutions or diagnostic contrast; available in a variety of lengths and diameters; braided support matrix and hydrophilic coating (distal segment); Spex LP has 3 radiopaque markers spaced equally along the distal shaft at 50-mm increments, to aid in estimating geometry within the vascular system |
| Reflow Medical, Inc | Wingman14 CTO Crossing Catheter | 2.7 | 65, 135, 150 | 0.039 | A beveled tip catheter intended to be used in conjunction with steerable guidewires to access discrete regions of the peripheral vasculature; the Wingman Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable bevel tip) and activating handle |
| Reflow Medical, Inc | Wingman14C CTO Crossing Catheter | 2.7 | 90, 135, 150 | 0.039 | A beveled tip catheter intended to be used in conjunction with steerable guidewires to access discrete regions of the peripheral vasculature; the Wingman Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable bevel tip) and activating handle |
| Reflow Medical, Inc | Wingman18 CTO Crossing Catheter | 3.8 | 90, 135, 150 | 0.052 | A beveled tip catheter intended to be used in conjunction with steerable guidewires to access discrete regions of the peripheral vasculature; the Wingman Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable bevel tip) and activating handle |
| Reflow Medical, Inc | Wingman35 CTO Crossing Catheter | 4.6 | 65, 90, 135 | 0.066 | A beveled tip catheter intended to be used in conjunction with steerable guidewires to access discrete regions of the peripheral vasculature; the Wingman Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable bevel tip) and activating handle |
| Reflow Medical, Inc | Spex35 Shapeable Support Microcatheter | 4.6 | 50, 90, 135, 150 | 0.066 | Single lumen, shapeable tip support catheter designed to access the peripheral vasculature; allows for exchange of guidewires and other interventional devices and provides a conduit for delivery of saline solutions or diagnostic contrast; available in a variety of lengths; braided support matrix and hydrophlilic coating (distal segment); the distal tip of the Spex has one radiopaque marker |
Advertisement
Advertisement
Other Devices / CTO Crossing Devices
View Chart| Company Name | Product Name | Catheter Size (F) | Wire Size (inch) | Working Length (cm) | Minimum Guiding Catheter ID (inch) | Comments |
|---|---|---|---|---|---|---|
| Reflow Medical, Inc | Wingman14 CTO Crossing Catheter | 2.7 | 0.014 | 65, 135, 150 | 0.039 | A beveled tip catheter intended to be used in conjunction with steerable guidewires to access discrete regions of the peripheral vasculature; the Wingman Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable bevel tip) and activating handle |
| Reflow Medical, Inc | Wingman14C CTO Crossing Catheter | 2.7 | 0.014 | 90, 135, 150 | 0.039 | A beveled tip catheter intended to be used in conjunction with steerable guidewires to access discrete regions of the peripheral vasculature; the Wingman Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable bevel tip) and activating handle |
| Reflow Medical, Inc | Wingman18 CTO Crossing Catheter | 3.8 | 0.018 | 90, 135, 150 | 0.052 | A beveled tip catheter intended to be used in conjunction with steerable guidewires to access discrete regions of the peripheral vasculature; the Wingman Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable bevel tip) and activating handle |
| Reflow Medical, Inc | Wingman35 CTO Crossing Catheter | 4.6 | 0.035 | 65, 90, 135 | 0.066 | A beveled tip catheter intended to be used in conjunction with steerable guidewires to access discrete regions of the peripheral vasculature; the Wingman Crossing Catheter consists of a support catheter, with a user controlled radiopaque guide tip (5-mm extendable bevel tip) and activating handle |
Catheters / Angiographic Catheters: Selective, Hydrophilic Coated
View Chart| Company Name | Product Name | Type | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Radiopaque Tip (Yes/No) | Variety of Selective Shapes |
|---|---|---|---|---|---|---|---|
| Reflow Medical, Inc | SpexLP 18 Shapeable Support Microcatheter | Shapeable tip, braid reinforced | 2.5 | 90, 135, 150 | 0.018 | Yes | User's choice |
| Reflow Medical, Inc | SpexLP 35 Shapeable Support Microcatheter | Shapeable tip, braid reinforced | 3.8 | 90, 135, 150 | 0.035 | Yes | User's choice |
| Reflow Medical, Inc | SpexLP 14 Shapeable Support Microcatheter | Shapeable tip, braid reinforced | 2.2 | 90, 135, 150 | 0.014 | Yes | User's choice |
| Reflow Medical, Inc | Spex35 Shapeable Support Microcatheter | Shapeable tip, braid reinforced | 4.6 | 50, 90, 135, 150 | 0.035 | Yes | User's choice |
Catheters / Microcatheters
View Chart| Company Name | Product Name | Type of Catheter Construction | Proximal Size (F) | Middle Size (F) | Distal Size (F) | Catheter Working Length (cm) | Catheter Endhole Diameter ID (inch) | Recommended Guidewire Size (inch) | Radiopaque Tip (Yes/No) | Hydrophilic Coating (Yes/No) |
|---|---|---|---|---|---|---|---|---|---|---|
| Reflow Medical, Inc | coraForce Coronary Catheter | Polymer tip, stainless steel braid, integrated wire coating | 2.2 | 2.2 | 1.3 | 135, 150 | 0.016 | 0.014 | Yes | Yes |
| Reflow Medical, Inc | Wingman18 CTO Crossing Catheter | Braided with extendable beveled tip | 3.8 | 3.8 | 3.8 | 90, 135, 150 | 0.032 | 0.018 | Yes | Yes |
| Reflow Medical, Inc | Wingman14C CTO Crossing Catheter | Braided with extendable beveled tip | 2.7 | 2.7 | 2.7 | 90, 135, 150 | 0.024 | 0.014 | Yes | Yes |
| Reflow Medical, Inc | Wingman14 CTO Crossing Catheter | Braided with extendable beveled tip | 2.7 | 2.7 | 2.7 | 65, 135, 150 | 0.022 | 0.014 | Yes | No |
| Reflow Medical, Inc | Wingman 35 CTO Crossing Catheter | Braided with extendable beveled tip | 4.6 | 4.6 | 4.6 | 65, 90, 135 | 0.038 | 0.050 | Yes | Yes |
| Reflow Medical, Inc | SpexLP 35 Shapeable Support Microcatheter | Low profile, shapeable tip, braid reinforced | 3.8 | 3.8 | 2.9 | 90, 135, 150 | 0.038 | 0.035 | Yes | Yes |
| Reflow Medical, Inc | SpexLP 18 Shapeable Support Microcatheter | Low profile, shapeable tip, braid reinforced | 2.5 | 2.5 | 1.6 | 90, 135, 150 | 0.021 | 0.018 | Yes | Yes |
| Reflow Medical, Inc | SpexLP 14 Shapeable Support Microcatheter | Low profile, shapeable tip, braid reinforced | 2.2 | 2.2 | 1.4 | 90, 135, 150 | 0.018 | 0.014 | Yes | Yes |
| Reflow Medical, Inc | Spex35 Shapeable Support Microcatheter | Shapeable tip, braid reinforced | 4.6 | 4.6 | 4.6 | 50, 90, 135, 150 | 0.038 | 0.035 | Yes | Yes |
| Reflow Medical, Inc | coraFlex Coronary Catheter | Polymer tip, stainless steel braid, integrated wire coating | 2.2 | 2.2 | 1.4 | 135, 150 | 0.016 | 0.014 | Yes | Yes |
| Reflow Medical, Inc | coraCross Coronary Catheter | Polymer tip, stainless steel braid, integrated wire coating | 3.2 | 3.2 | 2.2 | 135, 150 | 0.016 | 0.014 | Yes | Yes |
Other Devices / Retrievable Scaffold Therapy
View Chart| Company Name | Product Name | Material Used | Introducer Size (F) | Guidewire Compatibility (inch) | Device Diameter (mm) | Device Length (mm) | Delivery System Length | US FDA Indicated Use | |
|---|---|---|---|---|---|---|---|---|---|
| Reflow Medical, Inc | Spur | Nitinol | 6 | 0.014 | 3, 4 | 60, 65 | 135 | Intended as an adjunct to percutaneous transluminal angioplasty (PTA) to dilate stenoses in infrapopliteal arteries ranging in diameter from 2.5 mm to 4.5 mm |
More Categories:
Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View AllAdvertisement