Group 7 Copy 3 Created with Sketch.
News Issue Archive Device Guide Calendar Subscribe Advertising

MENU

Centers

Carotid Dialysis EVAR Embolization HTN Limb Salvage Neurointervention Oncology PE Radial Regulatory Renal SFA TEVAR Venous

News Current Issue Archive Device Guide Calendar Subscribe Advertising About Contact Privacy Submissions
Carotid Dialysis EVAR Embolization HTN Limb Salvage Neurointervention Oncology PE Radial Regulatory Renal SFA TEVAR Venous

Back to Top

Advertisement

Advertisement

US Company Directory


Bentley InnoMed GmbH (distributed by Cook Medical)

Lotzenäcker 3, 72379 Hechingen, Germany

PHONE: +49 (0) 7471 984 995 10

down-arrow Created with Sketch.
down-arrow Created with Sketch.

Catheters / Specialty Catheters

View Chart
Company Name Product Name Catheter Size (F) Working Length (cm) Minimum Guiding Catheter ID (inch) Comments
Bentley InnoMed GmbH (distributed by Cook Medical) BeBack Crossing & Re-Entry Catheter 4 80, 120 4 F–0.018 inch; 6 F for crossover A low-profile support catheter that has a crossing and targeted re-entry capability with a length-adjustable and 360° rotational nitinol needle; the C-shaped radiopaque marker indicates in which direction the curved needle protrudes from the tip of the catheter; antegrade, retrograde, and crossover are possible for intraluminal and subintimal approach on 0.018-inch wire platform
Bentley InnoMed GmbH (distributed by Cook Medical) BeBack Crossing & Re-Entry Catheter 2.9 80, 120 2.9 F–0.014 inch; 5 F for crossover A low profile support catheter that has a crossing and targeted re-entry capability with a length-adjustable and 360° rotational nitinol needle; the C-shaped radiopaque marker indicates in which direction the curved needle protrudes from the tip of the catheter; antegrade, retrograde, and crossover are possible for intraluminal and subintimal approach on 0.014 wire platform

Advertisement

Advertisement

Other Devices / CTO Crossing Devices

View Chart
Company Name Product Name Catheter Size (F) Wire Size (inch) Working Length (cm) Minimum Guiding Catheter ID (inch) Comments
Bentley InnoMed GmbH (distributed by Cook Medical) BeBack Crossing & Re-Entry Catheter 4 0.018 80, 120 4 F–0.018 inch; 6 F for crossover A low-profile support catheter that has a crossing and targeted re-entry capability with a length-adjustable and 360° rotational nitinol needle; the C-shaped radiopaque marker indicates in which direction the curved needle protrudes from the tip of the catheter; antegrade, retrograde, and crossover are possible for intraluminal and subintimal approach on 0.014- and 0.018-inch wire platform
Bentley InnoMed GmbH (distributed by Cook Medical) BeBack Crossing & Re-Entry Catheter 2.9 0.014 80, 120 2.9 F–0.014 inch; 5 F for crossover A low-profile support catheter that has a crossing and targeted re-entry capability with a length-adjustable and 360° rotational nitinol needle; the C-shaped radiopaque marker indicates in which direction the curved needle protrudes from the tip of the catheter; antegrade, retrograde, and crossover are possible for intraluminal and subintimal approach on 0.014-inch wire platform

More Categories:

Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View All

Advertisement

Latest News


November 2, 2026

Inquis Medical Launches SENSE-PE Registry of Aventus Thrombectomy System

October 30, 2026

AMA Advances Framework for Clinical AI Liability

October 30, 2026

Rampart Launches Vanguard Total-Body Radiation Protection for Interventional Imagers

Most Read Articles


Improving PAD Awareness, Access, and Amputation Prevention

With Eric A. Secemsky, MD, MSc, RPVI, FACC, FAHA, FSCAI, FSVM

The 2026 AHA/ACC Guideline for the Management of Acute Pulmonary Embolism

By Geoffrey D. Barnes, MD, MSc; Allison Burnett, PharmD; Jay Giri, MD, MPH; and Soophia Naydenov, MD

SEISMIQ™ IVL System as a Next-Generation Technology Offering for Complex PAD

With Jaafer Golzar, MD, FACC, FSCAI, and Gregory A. Stanley, MD, FACS

Back to Top
Carotid Dialysis EVAR Embolization HTN Limb Salvage Neurointervention Oncology PE Radial Regulatory Renal SFA TEVAR Venous
Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Pulmonary Embolism Radial Regulatory Renal SFA TEVAR Venous

News• Current Issue• Archive• Device Guide• Advertising• About Calendar• Contact• Privacy• Submissions• Subscriptions


Endovascular Today (ISSN 1551-1944 print and ISSN 2689-792X online) is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field.



magazine Created with Sketch.

Free Print Subscriptions

Fill 1 Created with Sketch.

Email Newsletter



twitter-icon LinkedIn Created with Sketch. instagram BlueSky-Circle
Cardiac Interventions Today
Group 7 Copy 3 Created with Sketch.
bmc-secondary-mark-color copy Created with Sketch.

© 2026 Bryn Mawr Communications II, LLC.  
All Rights Reserved   •   Privacy Policy

one-trust-button