Carlo Trani, MD
Dipartimento di Scienze Cardiovascolari
Fondazione Policlinico Universitario A: Gemelli
IRCCS–Università Cattolica del Sacro Cuore
Rome, Italy
Disclosures: Speaker’s fees from QualiMed.

Iliac endovascular interventions are commonly performed via a transfemoral approach. More recently, alternative approaches through the wrist arteries (mainly transradial but also transulnar) in selected patients have been proposed with the aim of reducing access site complications and possibly improving clinical outcomes. Yet, the small size of the forearm arteries makes iliac device miniaturization a critical issue for treatment diffusion.

There are currently very few low-profile devices with the necessary extended shaft length to perform peripheral revascularization via a 5-F transradial approach. Additionally, when performing iliac stenting, there are almost no low-profile balloon-expandable stents available that are suitable for true < 6-F arterial access, which is the accepted limit for safe transradial access in unselected patients.

This article describes the first implantation of the new QBX 18 (5 F) balloon-expandable iliac stent (QualiMed; Figure 1) through a 6-F coronary guiding catheter via a true 5-F transulnar access to treat iliofemoral disease in a patient who was not amenable for transfemoral access.

Figure 1. The QBX 18 balloon-expandable stent.

CASE STUDY

Patient History

A 68-year-old woman with previous (5 years before) bilateral carotid endoarterectomy and mechanical aortic prosthesis implantation (7 years prior) was admitted with severe right leg claudication at about 50 meters (Fontaine IIb; Rutherford 3). Seven months before, the patient had undergone endovascular aneurysm repair (EVAR) to treat an infrarenal abdominal aortic aneurysm.

A Doppler ultrasound performed 1 week before admission had shown subocclusion of the right common iliac artery (CIA) and tight stenosis of the common femoral artery (CFA) with significant flow acceleration (4.5 m/sec).

CTA documented diffuse calcific disease of the right external iliac artery (EIA), immediately distal to the previously implanted endoprosthesis, and a subocclusive stenosis at the junction with the CFA (Figure 2). After team discussion with vascular surgeons, percutaneous transluminal angioplasty was planned.

Figure 2. Three-dimensional CTA reconstruction.

Intervention

Due to the previous EVAR, a contralateral femoral approach was not feasible because the lesion location made ipsilateral retrograde access troublesome, and therefore an antegrade approach through the wrist was selected.

After confirming patency of the palmar arch by reverse Allen test, left ulnar access was preferred because radial pulse was weaker on palpation. To limit ulnar artery injury, the 5-in-6-F Glidesheath Slender sheath (Terumo Interventional Systems), a recently developed thinner wall sheath with a 5-F outer diameter and 6-F inner lumen, was used.

A 6-F, 125-cm-long multipurpose guiding catheter was advanced over a 0.035-inch J-tipped guidewire down to the descending aorta, and angiography was performed showing severe sequential stenosis of the right EIA and CFA with patent aortoiliac endoprosthesis.

After advancing the guiding catheter further down selectively into the right CIA, the lesion was crossed with a 0.018-inch, 400-cm-long wire, which was advanced into the right superficial femoral artery. An extended shaft length (180 cm) 6- X 40-mm balloon was advanced over the guidewire, and then predilation of both CFA and EIA was performed.

Two overlapping self-expandable nitinol stents (6 X 80 mm and 7 X 60 mm) with extended shaft length (180 cm) were deployed, starting from the CFA up to the EIA and then postdilated with the previously used 6- X 40-mm balloon.

Due to a residual significant focal stenosis in the segment between the stent and previously implanted endoprosthesis (Figure 3), the decision was made to implant a short balloon-expandable stent to optimize the result. The availability of the QBX 18 (5 F) cobalt chromium balloon-expandable iliac stent provided an opportunity to complete the procedure through the 6-F guiding catheter and avoid sheath upsizing. This newly developed stent with an extremely low profile was developed specifically to be delivered through a 6-F guiding catheter (5-F sheath).

Figure 3. EIA focal stenosis (arrow) after stent deployment into the CFA.

A 9- X 26-mm QBX 18 (5 F) stent was deployed into the proximal EIA, overlapping the previously implanted stent at one site and the distal end of EVAR at the other one (Figure 4A and 4B). Final angiography showed excellent result with no residual stenosis (Figure 5).

Figure 4. Fluoroscopic view of the undeployed (A) and deployed (B) QBX stent.

Figure 5. Final angiogram showing no residual stenosis.

No periprocedural complications were noticed. The patient ambulated prior to discharge and reported marked improvement of claudication. A postprocedure Doppler ultrasound revealed patency of implanted stents with normal flow (peak systolic velocity, 1.5 m/sec). The patient was discharged on aspirin, clopidogrel, and a statin.

DISCUSSION

Recent technical improvements of peripheral devices have resulted in increased compatibility and distal support and have made it feasible to treat peripheral artery disease with a transradial or transulnar approach.

It is commonly accepted that balloon-expandable stents fare better in some iliac lesions (ie, ostial or heavily calcified stenoses) due to their higher radial force and more precise deployment when compared with self-expanding stents. However, iliac balloon-expandable stents usually require 6-F or larger sheaths or 8-F guiding catheters.

In the present case, we were able to implant a 9-mm-diameter balloon-expandable stent through a 6-F guiding catheter with a 5-in-6-F slender sheath, thus leaving behind a true 5-F hole at the entry site. This has two major implications: (1) This shows how iliac stenting can be performed by wrist access using the standard transradial coronary stenting technique, and (2) it opens the door for expanding the transradial approach selection to a broader range of patients with peripheral artery disease, including female patients or those with small radial arteries who are not otherwise amenable for transradial treatment.

CONCLUSION

The combination of new equipment, such as slender sheaths and the QBX 18 (5 F) balloon-expandable stent, may allow operators to safely and effectively perform iliac stenting by transradial or transulnar access. This can further prompt the adoption of a transradial approach for peripheral interventions.