Aortic (AAA) / Diagnostic Catheters
View Chart| Company Name | Product Name | Catheter Type | Size (F) | Recommended Introducer Size (F) | Guidewire Compatibility (inch) | Catheter Length (cm) |
|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | Performa Vessel Sizing Catheters | Vessel sizing | 4, 5 | 4, 5 | 0.035 | 65, 80, 100 |
Advertisement
Advertisement
Aortic (AAA) / Guidewires
View Chart| Company Name | Product Name | Diameter (inch) | Length (cm) | Flexible Tip Length (cm) |
|---|---|---|---|---|
| Merit Medical Systems, Inc. | InQwire Amplatz Guide Wires | 0.035, 0.038 | 75, 145, 180, 260 | 1, 3.5, 4, 6, 7; 3-mm J-shaped tip |
| Merit Medical Systems, Inc. | InQwire Guide Wires | 0.014, 0.018, 0.025, 0.035, 0.038 | 80, 150, 180, 260 | Bentson: 10, 15, and 23; Newton: 15, 18, and 23; J: 1.5, 3, 6, and 15 |
Aortic (AAA) / Occlusion/Molding Balloons
View Chart| Company Name | Product Name | Size (F) | Recommended Introducer Size (F) | Guidewire Compatibility (inch) | Catheter Length (cm) | Maximum Inflated Balloon Diameter (mm) |
|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | Q50X Stent Graft Balloon Catheter | 8 | 10 | 0.038 or smaller | 65, 100 | 50 |
Aortic (TAA) / Access Needles
View Chart| Company Name | Product Name | Gauge | Length (cm) |
|---|---|---|---|
| Merit Medical Systems, Inc. | Merit Advance Angiographic Needles | 18, 19, 20, 21 (smooth and echo-enhanced) | 2.5, 4, 7, 9 |
| Merit Medical Systems, Inc. | Merit Advance Angiographic Safety Needles | 18, 21 | 7 |
Aortic (TAA) / Diagnostic Catheters
View Chart| Company Name | Product Name | Catheter Type | Size (F) | Recommended Introducer Size (F) | Guidewire Compatibility (inch) | Catheter Length (cm) |
|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | Impress Diagnostic Catheters | Peripheral diagnostic, braided and nonbraided, selective and flush | 4, 5 | 4, 5 | 0.035, 0.038 | 30, 40, 65, 80, 90, 100, 110, 125 |
| Merit Medical Systems, Inc. | Impress Hydrophilic Diagnostic Catheters Coated (Legato) | Hydrophilic, braided and nonbraided, peripheral diagnostic, selective and flush catheters | 4, 5 | 4, 5 | 0.038 | 40, 65, 80, 100, 125 |
| Merit Medical Systems, Inc. | Performa Diagnostic Catheters | Peripheral diagnostic, braided and nonbraided, selective and flush | 4, 5, 6 | 4, 5, 6 | 0.035, 0.038 | 40, 65, 80, 90, 100, 110, 120, 125 |
| Merit Medical Systems, Inc. | Performa Vessel Sizing Catheters | Vessel sizing | 4, 5 | 4, 5 | 0.035 | 65, 80, 100 |
Aortic (TAA) / Guidewires
View Chart| Company Name | Product Name | Diameter (inch) | Length (cm) | Flexible Tip Length (cm) |
|---|---|---|---|---|
| Merit Medical Systems, Inc. | InQwire Amplatz Guide Wires | 0.035, 0.038 | 75, 145, 180, 260 | 1, 3.5, 4, 6, 7; 3-mm J-shaped |
| Merit Medical Systems, Inc. | InQwire Guide Wires | 0.014, 0.018, 0.025, 0.035, 0.038 | 80, 100, 150, 180, 260 | Bentson: 10, 15, 23; Newton: 15, 18, 23; J: 1.5, 3, 6, and 15 |
Aortic (TAA) / Occlusion/Molding Balloons
View Chart| Company Name | Product Name | Size (F) | Recommended Introducer Size (F) | Guidewire Compatibility (inch) | Catheter Length (cm) | Maximum Inflated Balloon Diameter (mm) |
|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | Q50X Stent Graft Balloon Catheter | 8 | 10 | 0.038 or smaller | 65, 100 | 50 |
Catheters / Angiographic Catheters: Flush
View Chart| Company Name | Product Name | Type | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Radiopaque Tip (Yes/No) | Variety of Selective Shapes |
|---|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | Performa/Impress | Both | 4, 5, 6 | 30, 40, 65, 80, 90, 110, 125 | 0.035, 0.038 | Yes | Pigtail, straight, contralateral (modified hook), ultra bolus (racquet) pediatric |
Catheters / Angiographic Catheters: Flush, Radiopaque Bands
View Chart| Company Name | Product Name | Measuring Increments | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Radiopaque Tip (Yes/No) | Variety of Selective Shapes |
|---|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | Pediatric | 1 cm | 3 | 65, 80 | 0.035 | Yes | Pigtail |
| Merit Medical Systems, Inc. | Performa | 1, 2 cm | 4, 5 | 65, 80, 90, 100 | 0.035 | Yes | Pigtail, straight, ultra bolus, modified hook |
Catheters / Angiographic Catheters: Selective, Hydrophilic Coated
View Chart| Company Name | Product Name | Type | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Radiopaque Tip (Yes/No) | Variety of Selective Shapes |
|---|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | Impress Hydrophilic Catheters Coated (Legato) | Braided, selective, and flush | 4–5 | 40, 65, 80, 100, 125 | 0.038 | Yes | Wide variety of cerebral, visceral, and multipurpose available |
Catheters / Angiographic Catheters: Selective, Nonhydrophilic Coated
View Chart| Company Name | Product Name | Type | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Radiopaque Tip | Variety of Selective Shapes |
|---|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | Impress Diagnostic Catheters | Peripheral diagnostic, braided and nonbraided, selective | 4, 5 | 30, 40, 65, 80, 90, 100, 110, 120, 125 | 0.035, 0.038 | Yes | Wide variety of cerebral, visceral, and peripheral shapes |
| Merit Medical Systems, Inc. | Performa Diagnostic Catheters | Peripheral, braided and nonbraided, selective and flush | 4, 5, 6 | 40, 65, 80, 90, 110, 125 | 0.035, 0.038 | Yes | Wide variety |
Catheters / Drainage Catheters
View Chart| Company Name | Product Name | Type | Tip | Size (F) | Length (cm) | Durometer | Radiopaque Tip (Yes/No) |
|---|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | ReSolve Non-Locking | General | J | 6.5, 7.5, 8.5, 10, 12 | 20, 25 | Polyurethane | Yes |
| Merit Medical Systems, Inc. | One-Step | Centesis | Pigtail | 4, 5, 6, 8 | 7, 10, 12, 15, 17 | FEP, polyurethane | No |
| Merit Medical Systems, Inc. | ReSolve Mini | General | Mini pigtail | 6.5, 7.5, 8.5, 10, 12, 14 | 17, 27, 42 | Polyurethane | Yes |
| Merit Medical Systems, Inc. | ReSolve Locking | General | Pigtail | 6.5, 7.5, 8.5, 10, 12, 14 | 15, 25, 40 | Polyurethane | Yes |
| Merit Medical Systems, Inc. | ReSolve Biliary | Biliary | Pigtail | 8, 10, 12, 14 | 40 | Polyurethane | Yes |
| Merit Medical Systems, Inc. | Aspira Tunneled Pleural and Peritoneal Catheter | Tunneled pleural and peritoneal | Straight | 15.5 | 72 | Silicone | Yes |
Catheters / Microcatheters
View Chart| Company Name | Product Name | Type of Catheter Construction | Proximal Size (F) | Middle Size (F) | Distal Size (F) | Catheter Working Length (cm) | Catheter Endhole Diameter ID (inch) | Recommended Guidewire Size (inch) | Radiopaque Tip (Yes/No) | Hydrophilic Coating (Yes/No) |
|---|---|---|---|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | Maestro | Nylon ribbon braiding | 2.8, 2.9 | 2.8, 2.9 | 2.1, 2.4, 2.8, 2.9 | 110, 130, 150 | 0.018, 0.020, 0.024, 0.027 | 0.016, 0.018, 0.021 | Yes, one markerband | Yes |
| Merit Medical Systems, Inc. | Pursue Microcatheter | Metal braided | 2.8, 2.9 | 2.8, 2.9 | 1.7, 2 | 110, 130, 150 | 0.016, 0.020 | 0.014, 0.018 | Yes, one markerband | Yes |
| Merit Medical Systems, Inc. | SwiftNinja Steerable Microcatheter | Tungsten-braided shaft | 2.9 (0.97 mm) | 2.9 (0.97 mm) | 2.4 (0.80 mm) | 125 | 0.021 | ≤ 0.018 | Yes, two markerbands | Yes |
Catheters / Specialty Catheters
View Chart| Company Name | Product Name | Catheter Size (F) | Working Length (cm) | Minimum Guiding Catheter ID (inch) | Comments |
|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | SureCross Support Catheter - 0.014 inch | 1.5 distal tip (0.014-inch wire) | 65, 90, 135, 150 | 0.066 (5 F) | Low-profile, hydrophilic-coated, tapered-tip catheter provides seamless catheter-to-guidewire transition to facilitate crossing of challenging lesions and tracking through tortuous anatomy |
| Merit Medical Systems, Inc. | SureCross Support Catheter - 0.018 inch | 1.7 distal tip (0.018-inch wire) | 65, 90, 135, 150 | 0.066 (5 F) | Low-profile, hydrophilic-coated, tapered-tip catheter provides seamless catheter-to-guidewire transition to facilitate crossing of challenging lesions and tracking through tortuous anatomy |
| Merit Medical Systems, Inc. | SureCross Support Catheter - 0.035 inch | 3.1 distal tip (0.035-inch wire) | 65, 90, 135, 150 | 0.079 (6 F) | Low-profile, hydrophilic-coated, tapered-tip catheter provides seamless catheter-to-guidewire transition to facilitate crossing of challenging lesions and tracking through tortuous anatomy |
Embolization / Embolic Particles/Beads
View Chart| Company Name | Product Name | Composition | Type | Sizes (µm) | Color Coded | CE Mark Indications |
|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | Bearing nsPVA Embolization Particles | PVA particles | Irregularly shaped particles | 45–150; 150–250; 250–355; 355–500; 500–710; 710–1,000; 1,000–1,180 | Labels are color-coded by particle size | Indicated for the embolization of AVMs and hypervascular tumors, including symptomatic uterine fibroids |
| Merit Medical Systems, Inc. | EmboGold Microspheres | Trisacryl with gelatin | Colored spherical embolic microspheres | 40–120; 100–300; 300–500; 500–700; 700–900; 900–1,200 | Labels are color-coded by microsphere size | Indicated for the embolization of AVMs, hypervascular tumors, including uterine fibroids, meningiomas, etc., and hemostatic embolization |
| Merit Medical Systems, Inc. | Embosphere Microspheres | Trisacryl with gelatin | Spherical embolic microspheres | 50–100; 40–120; 100–300; 300–500; 500–700; 700–900; 900–1,200 | Labels are color-coded by microsphere size | Indicated for the embolization of AVMs, prostate arteries for relief of symptoms related to benign prostatic hyperplasia, hypervascular tumors, including uterine fibroids, meningiomas, etc., and hemostatic embolization |
| Merit Medical Systems, Inc. | HepaSphere Microspheres | Sodium acrylate alcohol copolymer | Spherical drug-eluting microspheres; doxorubicin and irinotecan | 30–60 (120–240 reconstituted), 50–100 (200–400 reconstituted), 100–150 (400–600 reconstituted), 150–200 (600–800 reconstituted) | Labels are color-coded by microsphere size | Indicated for the embolization of blood vessels with or without delivery of doxorubicin or irinotecan for therapeutic or preoperative purposes in the following procedures: embolization of hepatocellular carcinoma and embolization of metastases to the liver |
Sheaths / Special Access Sheaths
View Chart| Company Name | Product Name | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Curved or Straight | Radiopaque Tip | Type of Special Access |
|---|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | PreludeEase Hydrophilic Sheath Introducers | 4–7 | 7, 11, 16, 23 | 0.018, 0.021, 0.025, 0.035 (nitinol mandrel with platinum tips; stainless steel; straight; single-ended floppy; double ended [3-mm J; floppy]; angled plastic jacketed wire) | Straight | No | Hydrophilic coated; radial access |
| Merit Medical Systems, Inc. | Prelude Short Sheaths | 5–8 | 4 | 0.018, 0.035, 0.038 (mandrel or stainless steel coil wires; straight or double ended [3-mm J and floppy]) | Straight | Yes | Dialysis access management |
| Merit Medical Systems, Inc. | Prelude Sheath Introducers | 4–7 | 7, 11, 23 | 0.018, 0.025 (mandrel or stainless steel wires; straight, angled or doubled ended [3-mm J and floppy]) | Straight | With or without | Radial access: combines mini access approach and sheath placement |
| Merit Medical Systems, Inc. | Merit MAK, SMAK and PAK: Mini Access Kits Regular and Stiffened, Pedal Access Kits | 4, 5 (available with 21-gauge X 7-cm smooth and echo-enhanced needles and 21-gauge X 4-cm echo-enhanced needles; 4, 5 stiffened dilator kits are available) | 10, 15 | 0.018 X 40, 60 cm (stainless steel mandrel with stainless, platinum coiled tips; nitinol mandrel with platinum or palladium coiled tips) | Straight | No | Microaccess (wire also available as standalone and two additional configurations: 0.018-inch X 60-cm stainless wire with platinum tip and 0.018-inch X 80-cm nitinol wire with platinum tip); 21-gauge X 9-cm smooth and echo-enhanced needles available; all components are available sterile, standalone |
| Merit Medical Systems, Inc. | MAK-NV Introducer System | 6 | 20 | 0.018 X 60 cm (nitinol with platinum tip; stainless with platinum tip), 0.038 X 150 cm (double-ended heavy duty) | Straight | Yes | Microaccess for nonvascular procedures; all components are available sterile, standalone |
| Merit Medical Systems, Inc. | Prelude Ideal Hydrophilic Sheath Introducer | 4, 5, 6, 7 | 7, 11, 16, 23 | 0.018, 0.021, 0.025 (nitinol mandrel with platinum tips; stainless steel; straight; single-ended floppy; double ended [3-mm J; floppy]; angled plastic jacketed wire) | Straight | No | Hydrophilic coated, radial access |
Sheaths / Standard Sheaths
View Chart| Company Name | Product Name | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Curved or Straight | Radiopaque Tip |
|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | Prelude ACT Sheath Introducers | 4.5, 5.5, 6.5, 7.5, 8.5 | 11 | 0.035, 0.038 (stainless steel wire double ended [3-mm J, floppy]) | Straight | No |
| Merit Medical Systems, Inc. | Prelude Sheath Introducers | 4–8 | 11, 23 | 0.018, 0.025, 0.035, 0.038 (mandrel or stainless steel coils; tips are straight, angled, or double ended [3-mm J, floppy]) | Straight | With or without |
Stents / Ostial Stent Positioning Systems
View Chart| Company Name | Product Name | Device Size (mm) | Working Length (cm) | Wire Diameters (inch) | Minimum Guiding Catheter (F) | Comments |
|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | Ostial Pro Stent Positioning System | 15-mm leg span | 127 | 0.014 (distal: 4 cm), 0.018 (proximal: 123 cm) | 6 ID (0.070 inch), 7 ID (0.078 inch), 8 ID (0.088 inch) | A guidewire system designed to provide consistent and precise stent implantation in aorto-ostial lesions during coronary or peripheral interventional procedures |
Stents / Self-Expanding Stent Grafts
View Chart| Company Name | Product Name | Materials Used | Introducer Size (F) | Guidewire Compatibility (inch) | Stent Diameter (mm) | Stent Length (mm) | Delivery System Length (cm) | CE Mark Indications | Comments |
|---|---|---|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | Merit Wrapsody Cell-Impermeable Endoprosthesis | Nitinol, ePTFE, PTFE | 8, 9, 10, 11, 12, 14 | 0.035 | 6, 7, 8, 9, 10, 12, 14, 16 | 30, 40, 50, 60, 70, 75, 80, 100, 125 | 80, 120 | Flexible self-expanding endoprosthesis indicated for use in hemodialysis patients for the treatment of stenosis or occlusion within the dialysis outflow circuit of an arteriovenous (AV) fistula or AV graft | The 6-10-mm-diameter stents come in lengths of 50, 75, 100, and 125 mm; the 12-, 14-, and 16-mm-diameter stents come in lengths of 30, 40, 50, 60, 70, and 80 mm |
Wires / Coiled Stainless Steel Guidewires
View Chart| Company Name | Product Name | Type | Diameter (inch) | Length (cm) | Tip Type | Antithrombogenic | Comments |
|---|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | InQwire PTFE Coated | J-tip fixed core, straight-tip fixed core, J-tip movable core, straight-tip movable core | 0.014, 0.018, 0.021, 0.025, 0.035, 0.038 | 80, 150, 180, 260 | Straight; Bentson 23-cm flex, Bentson 15 cm, Bentson short taper 10-cm flex; Newton LT, LLT, LLLT flex tips; super stiff straight tip; Rosen/1.5 mm; 1.5-, 3-, 6-, 15-mm J; double-flex ended; exchange 260-cm straight and J-tip | PTFE coating with and without heparin coating | – |
| Merit Medical Systems, Inc. | Prelude Sheath Wire | Stainless steel coils or plastic jacketed | 0.018, 0.021, 0.025, 0.035, 0.038 | 45, 50, 80 | Straight, angled, or double ended (3-mm J; floppy) | – | – |
Wires / Hydrophilic Guidewires
View Chart| Company Name | Product Name | Type | Diameter (inch) | Length (cm) | Tip Type |
|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | True Form Reshapable Guide Wire | Stainless steel | 0.014 | 145, 165, 180 | Straight, angled |
| Merit Medical Systems, Inc. | Splash Hydrophilic Coated Guide Wire | Nitinol | 0.018, 0.025, 0.035, 0.038 | 80, 150, 180, 220, 260 | Straight, angled, and straight long taper; tip flexibility 5 cm; available in standard and stiff configurations |
Wires / Mandril/Specialty Guidewires
View Chart| Company Name | Product Name | Type | Diameter (inch) | Length (cm) | Tip Type | Coating Type |
|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | InQwire: Marker Wire | Fixed core | 0.018 | 80, 120 | Straight 20-cm nitinol | Hydrophilic |
| Merit Medical Systems, Inc. | MAK (Mini Access Kits) Wires | Mandrel, nitinol with platinum tip, stainless steel, or nitinol core | 0.018 | 40, 60, 80 | Stainless steel, platinum, or palladium coil tips; stainless steel or nitinol mandrel; straight | – |
| Merit Medical Systems, Inc. | Prelude Sheath Wire | Stainless steel coils | 0.035, 0.038 | 50, 80 | Double ended: straight and 3-mm J | – |
Other Devices / Assisted Compression Devices
View Chart| Company Name | Product Name | Type | Puncture Size (F) | Maximum Wire Compatibility | Comments |
|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | PreludeSYNC | Radial compression device | All | All | Personal, effective, and comfortable radial compression; available in two sizes and two inflation luer options |
| Merit Medical Systems, Inc. | PreludeSYNC EZ | Radial compression device | All | All | Personal, effective, and comfortable radial compression; available in two sizes and two inflation luer options |
| Merit Medical Systems, Inc. | Safeguard (12, 24 cm) | Pressure-assisted device | All | – | Assists manual compression and maintains hands-free pressure; adjustable pressure is applied to wound and access site via an inflatable bulb contained within an adhesive bandage, allowing visibility of the site; available in two sizes |
| Merit Medical Systems, Inc. | Safeguard Radial | Radial hemostasis | All | – | Provides direct compression on the radial artery; excellent site visibility through clear window; soft, nonlatex adhesive band for increased patient comfort |
Other Devices / CTO Crossing Devices
View Chart| Company Name | Product Name | Catheter Size (F) | Wire Size (inch) | Working Length (cm) | Minimum Guiding Catheter ID (inch) | Comments |
|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | Spinr High-Performance Guidewire Controller | – | 0.014–0.038 | – | 0.014 | Used to maneuver guidewires in the coronary and peripheral vasculature during interventional or diagnostic procedures; assists in accessing distal anatomy, navigating tortuous vessels, crossing old lesions, and working through fresh blockages |
Other Devices / Dialysis Catheters
View Chart| Company Name | Product Name | Size (F) | Tip-to-Cuff Insertion Length (cm) | Tip Type | Number of Lumens | Sideholes (Yes/No) | Coated (Yes/No) | Acute or Chronic |
|---|---|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | BioFlo DuraMax Catheter | 16 | 15–50 | Curved step-tip | 2 | Yes | Yes | Chronic |
| Merit Medical Systems, Inc. | ProGuide | 14.5 | 19, 23, 27, 31, 35 | Step-tip | Two | Yes | No | Chronic |
| Merit Medical Systems, Inc. | CentrosFLO Long-Term Hemodialysis Catheter | 16 | 15, 17, 19, 23, 27, 31 | Self-centering split tip | Two | Yes | No | Chronic |
| Merit Medical Systems, Inc. | Flex-Neck Peritoneal Dialysis Catheter | 15 | 1.5, 4.5, 6.5, 9.5, 13.5, 14, 15.5 | Coil, straight | One | Yes | No | Chronic |
Other Devices / Endovenous Ablation
View Chart| Company Name | Product Name | Technology | Wavelength (nm) | Sheath Size (F) | Sheath Length (cm) | CE Mark Indications |
|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | ClariVein OC | Mechanochemical | – | 4, 5 | – | Indicated for infusion of physician-specified agents in the peripheral vasculature including for endovascular occlusion of incompetent veins in patients with superficial venous reflux |
Other Devices / Hybrid Vascular Grafts
View Chart| Company Name | Product Name | Materials Used | Nitinol Reinforced Section Diameter (mm) | Nitinol Reinforced Section Length (cm) | Vascular Graft Section Introducer Size (F) | Vascular Graft Section Recommended Guidewire (inch) | Introducer Size (F) | Recommended Guidewire (inch) | CE Mark Indications |
|---|---|---|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | Hero Graft | Nitinol, silicone, barium sulfate, tantalum, ePTFE, PTFE, and titanium | 5 ID | 40 (customizable length) | – | 0.035 for over-the-wire | 20 peelaway for over-the-wire | 59 (minimum length) | Indicated for end-stage renal disease patients on hemodialysis who have exhausted all other access options; see Instructions for Use for full indication, contraindication, and caution statements; Rx only |
Other Devices / Snares
View Chart| Company Name | Product Name | Catheter Size/Length (F/cm) | Working Diameters (mm) | Snare Length (cm) | Snare Type |
|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | EN Snare Endovascular Snare System | 3.2/150, 6, 7/100 | 2–4, 4–8, 6–10, 9–15, 12–20, 18–30, 27–45 | 120, 175 | Incorporates an interlaced triple-loop design which conforms to vessel walls to promote accurate and reliable foreign body retrieval; the super elastic nitinol provides kink resistance and torque control; the platinum strands around the loops provide excellent fluoroscopic visualization |
| Merit Medical Systems, Inc. | One Snare Endovascular Snare System | 4/48, 4/100, 6/48, 6/100 | 5, 10, 15, 20, 25, 30, 35 | 65, 120 | Single 90° angle loop to optimize retrieval and manipulation of foreign objects; nitinol loop wrapped with gold-plated tungsten provides strength and shape retention and enhances visibility under fluoroscopy |
| Merit Medical Systems, Inc. | One Snare Microsnare System | 2.3–3/150, 175 | 2, 4, 7 | 175, 200 | Single 90° loop configuration and gold tungsten coils (for enhanced visualization) |
| Merit Medical Systems, Inc. | One Snare Petite Snare System | 4, 6 | 48 | 65 | Single 90° loop configuration and gold tungsten coils (for enhanced visualization) |
Other Devices / Therapeutic Infusion Systems
View Chart| Company Name | Product Name | Sheath Compatibility (F) | Guidewire Compatibility (inch) | Working Length (cm) | Mode of Operation | CE Mark Indications |
|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | Fountain Infusion System | 4, 5 | 0.035 | 45, 90, 135 | – | Intended to administer infusions of various therapeutic solutions into the peripheral vasculature of a patient |
| Merit Medical Systems, Inc. | Mistique Infusion Catheter | 5 | 0.035 | 45, 90, 135 | Can be used for slow, continuous infusion, or pulse infusion | Intended to administer infusions of various therapeutic solutions into the peripheral vasculature of a patient |
| Merit Medical Systems, Inc. | Fountain Occluding Wire | 4, 5 | – | 45, 90, 135 | Can be used for slow, continuous infusion, or pulse infusion | Intended to administer infusions of various therapeutic solutions into the peripheral vasculature of a patient |
| Merit Medical Systems, Inc. | Fountain Infusion System: Catheter, Occluding Wire, and AcessPLUS Hemostasis Valve | 4, 5 | 0.035 | 45, 90, 135 | – | Intended to administer infusions of various therapeutic solutions into the peripheral vasculature of a patient |
| Merit Medical Systems, Inc. | Fountain Infusion Catheter With Squirt Fluid Delivery System | 4, 5 | 0.035 (0.89 mm) | 45, 90, 135 | Fluid delivery system with consistent, forceful, pulsed injections for optimal thrombolysis procedures | Intended to administer infusions of various therapeutic solutions into the peripheral vasculature of a patient |
Other Devices / Thrombus Aspiration Devices
View Chart| Company Name | Product Name | Type | Maximum Tip Diameter (mm) | Minimum Guide Catheter Size (F) | Catheter Length (cm) |
|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | ASAP Aspiration Catheter Kit | Manual aspiration catheter and kit | 1.73 | Guiding catheter ID: 6 (≥ 0.070 inch) | 140 |
| Merit Medical Systems, Inc. | ASAPLP Aspiration Catheter Kit | Low-profile manual aspiration catheter and kit | 1.40 | Guiding catheter ID: 6 (≥ 0.066 inch) | 145 |
Other Devices / Inflation Devices
View Chart| Company Name | Product Name | Color | Pressure Range (atm) | Barrel Volume (mL) | Luminescent Gauge (Yes/No) | Gauge | Latch Type | Threads |
|---|---|---|---|---|---|---|---|---|
| Merit Medical Systems, Inc. | basix Touch | White/blue handle | 35 | 30 | Yes | Yes | Squeeze handle/one-handed prep | Yes |
| Merit Medical Systems, Inc. | basixCompak | White/clear | 30 | 20 | Yes | Yes | Squeeze handle | Yes |
| Merit Medical Systems, Inc. | Diamond Touch | White/blue handle | 35 | 30 | Yes | Digital | Squeeze handle/one-handed prep | Yes |
More Categories:
Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View AllAdvertisement