Group 7 Copy 3 Created with Sketch.
News Issue Archive Device Guide Calendar Subscribe Advertising

MENU

Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

News Current Issue Archive Device Guide Calendar Subscribe Advertising About Contact Privacy Submissions
Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

Back to Top

Advertisement

Advertisement

EUROPE. Company Directory


Terumo Neuro

35 Enterprise, Aliso Viejo, CA 92656

PHONE: (800) 990-8368 | FAX: (949) 247-8013

down-arrow Created with Sketch.
down-arrow Created with Sketch.

Balloons / Specialty Balloons

View Chart
Company Name Product Name Nominal Pressure (atm) Rated Burst Pressure (atm) Guidewire Compatibility (inch) Size (F) Sheath Compatibility (F) Shaft Length (cm) Balloon Diameters (mm) Balloon Lengths (cm)
Terumo Neuro Scepter Mini – 47.6 0.008 2.8 4 165 2.2 0.9
Terumo Neuro Scepter C Occlusion Balloon – 20.4 0.0165 2.8 4 150 4 1.5, 2
Terumo Neuro Scepter XC Occlusion Balloon – 20.4 0.0165 2.8 4 150 4 1.1

Advertisement

Advertisement

Catheters / Guiding Catheters

View Chart
Company Name Product Name Type Size (F) Length (cm) Internal Diameter (inch) Radiopaque Tip (Yes/No) Hydrophilic Coated
Terumo Neuro Chaperon Guiding Catheter Single PTFE layer with flat wire braid guiding catheter STR or MP2 tip shape 5 95 0.059 Yes Yes
Terumo Neuro Chaperon Guiding Catheter Single PTFE layer with flat wire braid guiding catheter STR or MP2 tip shape 6 95 0.071 Yes Yes
Terumo Neuro Chaperon Guiding Catheter System Guiding catheter with inner catheter system: STR/JB2, STR/VTR, STR/SIM, MP2/JB2, MP2/VTR, MP2/SIM tip shapes 4, 5 95, 117 0.041, 0.059 Yes Yes
Terumo Neuro Chaperon Guiding Catheter System Guiding catheter with inner catheter system: STR/JB2, STR/VTR, STR/SIM, MP2/JB2, MP2/VTR, MP2/SIM, BUR/JB2, BUR/VTR tip shapes 5, 6 95, 117 0.048, 0.071 Yes Yes

Catheters / Microcatheters

View Chart
Company Name Product Name Type of Catheter Construction Proximal Size (F) Middle Size (F) Distal Size (F) Catheter Working Length (cm) Catheter Endhole Diameter ID (inch) Recommended Guidewire Size (inch) Radiopaque Tip (Yes/No) Hydrophilic Coating (Yes/No)
Terumo Neuro Headway 27 PTFE liner with coil reinforcement 3.1 – 2.6 150 0.027 0.027 Yes Yes
Terumo Neuro Wedge Coil reinforcement and distal bulb 2.5 – 2 1.5 (distal length) 0.021 0.014 Yes Yes
Terumo Neuro Headway Duo Hybrid braid/coil design 2.1 – 1.6 156 0.0165 0.0165 Yes Yes
Terumo Neuro Headway Duo Hybrid braid/coil design 2.1 – 1.6 167 0.0165 0.0165 Yes Yes
Terumo Neuro Headway 21 PTFE liner with coil reinforcement 2.5 – 2 150 0.021 0.021 Yes Yes
Terumo Neuro Headway 17 Advanced Soft Tapered PTFE liner with coil reinforcement 2.4 – 1.7 150 0.017 0.017 Yes Yes
Terumo Neuro Headway 17 Advanced Tapered PTFE liner with coil reinforcement 2.4 – 1.7 150 0.017 0.017 Yes Yes

Embolization / Cerebral Coils

View Chart
Company Name Product Name Materials Used Coil Type Method of Detachment CE Mark Indications Comments
Terumo Neuro VFC Coils Bare-platinum coils MicroPlex coil system, complex shape, for filling V-Grip detachment controller, self-contained integrated power supply, rapid coil detachment: 0.75 seconds Intended for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistula; intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature This coils unique loop/wave shape and long length sizes seek out and fill available space efficiently
Terumo Neuro HyperSoft Helical Coils Bare-platinum coils MicroPlex coil system, helical shape, for filling and finishing V-Grip detachment controller, self-contained integrated power supply, rapid coil detachment: 0.75 seconds Intended for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistula; intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature Platinum coils provide versatile framework, stability, and conformability
Terumo Neuro HyperSoft 3D Coils Bare-platinum coils MicroPlex coil system, complex shape, for filling and finishing V-Grip detachment controller, self-contained integrated power supply, rapid coil detachment: 0.75 seconds Intended for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistula; intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature Platinum coils provide versatile framework, stability, and conformability
Terumo Neuro HydroSoft Helical Coils Hydrogel thread placed inside of platinum coil HydroCoil embolic system, helical shape, for filling and finishing V-Grip detachment controller, self-contained integrated power supply, rapid coil detachment: 0.75 seconds Intended for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistula; intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature Hydrogel technology provides a scaffold for endothelialization at the aneurysm neck
Terumo Neuro HydroSoft 3D Coils Hydrogel thread placed inside of platinum coil HydroCoil embolic system, complex shape, for filling and finishing V-Grip detachment controller, self-contained integrated power supply, rapid coil detachment: 0.75 seconds Intended for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistula; intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature Hydrogel technology provides a scaffold for endothelialization at the aneurysm neck
Terumo Neuro HydroFill Coils Hydrogel thread placed inside of platinum coil HydroCoil Embolic System, helical shape, for filling V-Grip detachment controller, self-contained integrated power supply, rapid coil detachment: 0.75 seconds Intended for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistula; intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature Hydrogel core of HydroFill coil line expands diameter of coil by 20% for efficient filling
Terumo Neuro Helical Coils Bare-platinum coils MicroPlex coil system, helical shape, for filling and finishing V-Grip detachment controller, self-contained integrated power supply, rapid coil detachment: 0.75 seconds Intended for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistula; intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature Platinum coils provide versatile framework, stability, and conformability
Terumo Neuro Cosmos Coils Bare-platinum coils MicroPlex coil system, complex shape, for framing and filling V-Grip detachment controller, self-contained integrated power supply, rapid coil detachment: 0.75 seconds Intended for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistula; intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature Platinum coils provide versatile framework, stability, and conformability
Terumo Neuro Complex Coils Bare-platinum coils MicroPlex coil system, complex shape, for framing and filling V-Grip detachment controller, self-contained integrated power supply, rapid coil detachment: 0.75 seconds Intended for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistula; intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature Platinum coils provide versatile framework, stability, and conformability
Terumo Neuro Compass Coils Bare-platinum coils MicroPlex coil system, complex shape, for framing and filling V-Grip detachment controller, self-contained integrated power supply, rapid coil detachment: 0.75 seconds Intended for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistula; intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature Platinum coils provide versatile framework, stability, and conformability
Terumo Neuro HydroFrame Coils Hydrogel thread placed inside of platinum coil HydroCoil Embolic System, complex shape, for framing and filling V-Grip detachment controller, self-contained integrated power supply, rapid coil detachment: 0.75 seconds Intended for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistula; intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature Hydrogel technology provides a scaffold for endothelialization at the aneurysm neck

Embolization / Liquid Embolics

View Chart
Company Name Product Name Viscosity Vial Size (mL) CE Mark Indications Comments
Terumo Neuro Phil Liquid Embolic System 12, 16, 36, 72 (cSt) 1 The Phil device is intended for use in the embolization of lesions in the peripheral and neurovasculature, including arteriovenous malformations and hypervascular tumors Nonadhesive liquid embolic made of copolymer covalently bonded with iodine and dissolved in DMSO

Stents / Carotid Artery Stenting Systems

View Chart
Company Name Product Name Tapered Stent Diameters (Proximal/Distal) (mm) Tapered Stent Lengths (mm) Straight Stent Diameters (mm) Straight Stent Lengths (mm) Embolic Protection Device Type Position CE Mark Indications
Terumo Neuro Casper RX In vivo tapering In vivo tapering 5–10 25, 37, 47; 22, 33, 40; 25, 35, 40; 25, 35, 40, 47; 33, 40; 35, 43 EmPro Embolic Protection System Dual-layer braided stent Sustained embolic protection Indicated for use in patients with carotid arterial atherosclerotic disease

Stents / Cerebral Stents

View Chart
Company Name Product Name Materials Used Stent Diameters (mm) Stent Lengths (mm) Recommended Guidewire Size (inch) Recommended Guide Catheter Size (inch)
Terumo Neuro LVIS EVO Intraluminal Support Device Nitinol with platinum core (DFT wire) 2.5, 3, 3.5, 4 12–34 0.014 0.0165, 0.017
Terumo Neuro LVIS Intraluminal Support Device Nitinol, tantalum 3.5, 4, 4.5, 5.5 Various 0.014 ID: 0.021
Terumo Neuro LVIS Jr. Intraluminal Support Device Nitinol, tantalum 2.5, 3.5 Various 0.014 0.0165, 0.017

Wires / Hydrophilic Guidewires

View Chart
Company Name Product Name Type Diameter (inch) Length (cm) Tip Type
Terumo Neuro Glidewire Gold Neuro Guidewire Hydrophilic nitinol guidewire 0.011, 0.014, 0.016, 0.018 180 45°, 70° angle
Terumo Neuro Traxcess Docking Wire Docking 0.014 115 –
Terumo Neuro Traxcess 7 Mini Soft 0.007 210 Soft
Terumo Neuro Traxcess 14 EX Support 0.014 200 STR, shapeable
Terumo Neuro Traxcess 14 Soft 0.014 200 STR, shapeable
Terumo Neuro Headliner Guidewire Hydrophilic nitinol guidewire 0.012 200 1.5-mm J tip, 45°, 90° angle, 90°/150° double angle
Terumo Neuro Headliner Guidewire Hydrophilic nitinol guidewire 0.014 200 45°, 70° angle, STR (shapeable)
Terumo Neuro Headliner Guidewire Hydrophilic nitinol guidewire 0.016 200 1.5-mm J tip, 90° angle, 90°/150° double angle

Other Devices / Thrombus Aspiration Devices

View Chart
Company Name Product Name Type Maximum Tip Diameter (mm) Minimum Guide Catheter Size (F) Catheter Length (cm)
Terumo Neuro Sofia Plus Aspiration Catheter Aspiration catheter Distal OD: 2.; ID: 0.070 inch 6 125, 131

Other Devices / Mechanical Thrombectomy (Neurovascular)

View Chart
Company Name Product Name Sheath Compatibility (F) Guidewire Compatibility (inch) Working Length (cm) Mode of Operation CE Mark Indications
Terumo Neuro Eric Retrieval Device 0.017- and 0.021-inch microcatheter 0.014 15, 20, 24, 30, 35, 44 Clot retriever device with intraluminal clot capture surface Intended for use in the revascularization of acute ischemic stroke caused by the intracranial occlusive vessels of patients who are not eligible for intravenous tissue plasminogen activator (IV tPA) or who fail IV tPA therapy
Terumo Neuro Sofia Plus Aspiration Catheter 6 – 125, 131 Aspiration catheter Indicated for general intravascular use, including the peripheral and neurovasculatures; can be used to facilitate introduction of diagnostic or therapeutic agents; not intended for use in coronary arteries; intended for use in the removal/aspiration of emboli and thrombi from selected blood vessels in the arterial system, including the peripheral and neurovasculatures

More Categories:

Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View All

Advertisement

Latest News


April 17, 2026

Bayer’s Asundexian FXIa Inhibitor Demonstrates Reduction in Ischemic Stroke in OCEANIC-STROKE Study

April 16, 2026

Rapid Medical’s Tigertriever 25 Cleared by FDA to Treat LVO Stroke

April 15, 2026

Stereotaxis to Acquire Robocath

Most Read Articles


A Private Practice Physician’s Experience Treating Chronic Venous Insufficiency

By Robert A. Edwards, DO

Update on Modern Complex Abdominal Aortic Repair Options

With Jason T. Lee, MD; Steven Maximus, MD, FACS; Gustavo Oderich, MD, FACS; Benjamin W. Starnes, MD, FACS; Carlos Timaran, MD; Kak Khee Yeung, MD, PhD, FEBVS; and Javairiah Fatima, MD, FACS, DFSVS

Transforming the Future of PE Care: Expanding Mechanical Thrombectomy Through Innovation

By Mehdi Shishehbor, DO, MPH, PhD

Back to Top
Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous
Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

News• Current Issue• Archive• Device Guide• Advertising• About Calendar• Contact• Privacy• Submissions• Subscriptions


Endovascular Today (ISSN 1551-1944 print and ISSN 2689-792X online) is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field.



magazine Created with Sketch.

Free Print Subscriptions

Fill 1 Created with Sketch.

Email Newsletter



twitter-icon LinkedIn Created with Sketch. instagram BlueSky-Circle
Cardiac Interventions Today
Group 7 Copy 3 Created with Sketch.
bmc-secondary-mark-color copy Created with Sketch.

© 2026 Bryn Mawr Communications II, LLC.  
All Rights Reserved   •   Privacy Policy

one-trust-button