US Company Directory


Terumo Neuro

35 Enterprise, Aliso Viejo, CA 92656

PHONE: (800) 990-8368 | FAX: (949) 247-8013

down-arrow Created with Sketch.
down-arrow Created with Sketch.

Balloons / Specialty Balloons (Neuro)

View Chart
Company Name Product Name Proximal OD (F) Distal OD (F) Tip Length (mm) Balloon Diameters (mm) Balloon Lengths (mm)
Terumo Neuro Scepter Mini 2.8 1.6 2.5 2.2 9
Terumo Neuro Scepter XC 2.8 2.1 5 4 11
Terumo Neuro Scepter C 2.8 2.1 5 4 10, 15, 20

Advertisement

Advertisement

Catheters / Guiding Catheters

View Chart
Company Name Product Name Type Size (F) Length (cm) Internal Diameter (inch) Radiopaque Tip (Yes/No) Hydrophilic Coated
Terumo Neuro Bobby Balloon guide catheter 8.4 95 0.086 Yes Yes
Terumo Neuro Chaperon Guiding catheter system offered with inner select catheters with a hydrophilic coating for navigation and vessel selection 5/6 95 0.059/0.071 Yes Chaperon catheter, no; inner select catheter, yes

Catheters / Specialty Catheters

View Chart
Company Name Product Name Catheter Size (F) Working Length (cm) Minimum Guiding Catheter ID (inch) Comments
Terumo Neuro SOFIA 5 115, 125 0.070 Designed for distal navigation and supports precise delivery of a variety of neurovascular therapies
Terumo Neuro SOFIA 6 115 0.085 Designed for distal navigation and supports precise delivery of a variety of neurovascular therapies

Embolization / Cerebral Coils

View Chart
Company Name Product Name Materials Used Coil Type Method of Detachment US FDA Indicated Use Comments
Terumo Neuro HydroFill Coils Hydrogel thread placed inside of platinum coil HydroCoil Embolic System, helical shape, for filling V-Grip detachment controller, self-contained integrated power supply, rapid coil detachment: 0.75 seconds Intended for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistulae; intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature Hydrogel core of HydroFill coil line expands diameter of coil by 20% for efficient filling
Terumo Neuro VFC Coils Bare-platinum coils MicroPlex Coil System, complex shape, for filling V-Grip detachment controller, self-contained integrated power supply, rapid coil detachment: 0.75 seconds Intended for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistulae; intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature VFC coil’s unique loop/wave shape and long length sizes seek out and fill available space efficiently
Terumo Neuro HyperSoft Helical Coils Bare-platinum coils MicroPlex Coil System, helical shape, for filling and finishing V-Grip detachment controller, self-contained integrated power supply, rapid coil detachment: 0.75 seconds Intended for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistulae; intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature Platinum coils provide versatile framework, stability, and conformability
Terumo Neuro HyperSoft 3D Coils Bare-platinum coils MicroPlex Coil System, complex shape, for filling and finishing V-Grip detachment controller, self-contained integrated power supply, rapid coil detachment: 0.75 seconds Intended for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistulae; intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature Platinum coils provide versatile framework, stability, and conformability
Terumo Neuro HydroSoft Helical Coils Hydrogel thread placed inside of platinum coil HydroCoil Embolic System, helical shape, for filling and finishing V-Grip detachment controller, self-contained integrated power supply, rapid coil detachment: 0.75 seconds Intended for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistulae; intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature Hydrogel technology provides a scaffold for endothelialization at the aneurysm neck
Terumo Neuro HydroSoft 3D Coils Hydrogel thread placed inside of platinum coil HydroCoil Embolic System, complex shape, for filling and finishing V-Grip detachment controller, self-contained integrated power supply, rapid coil detachment: 0.75 seconds Intended for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistulae; intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature Hydrogel technology provides a scaffold for endothelialization at the aneurysm neck
Terumo Neuro HydroFrame Coils Hydrogel thread placed inside of platinum coil HydroCoil Embolic System, complex shape, for framing and filling V-Grip detachment controller, self-contained integrated power supply, rapid coil detachment: 0.75 seconds Intended for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistulae; intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature Hydrogel technology provides a scaffold for endothelialization at the aneurysm neck
Terumo Neuro Helical Coils Bare-platinum coils MicroPlex Coil System, helical Shape, for filling and finishing V-Grip detachment controller, self-contained integrated power supply, rapid coil detachment: 0.75 seconds Intended for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistulae; intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature Platinum coils provide versatile framework, stability, and conformability
Terumo Neuro Complex Coils Bare-platinum coils MicroPlex Coil System, Complex Shape, for framing and filling V-Grip detachment controller, self-contained integrated power supply, rapid coil detachment: 0.75 seconds Intended for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistulae; intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature Platinum coils provide versatile framework, stability, and conformability
Terumo Neuro Cosmos Coils Bare-platinum coils MicroPlex Coil System, Complex Shape, for framing and filling V-Grip detachment controller, self-contained integrated power supply, rapid coil detachment: 0.75 seconds Intended for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistulae; intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature Platinum coils provide versatile framework, stability, and conformability

Stents / Cerebral Stents

View Chart
Company Name Product Name Materials Used Stent Diameters (mm) Stent Lengths (mm) Recommended Guidewire Size (inch) Recommended Guide Catheter Size (inch)
Terumo Neuro LVIS Jr Intraluminal Support Device Nitinol with tantalum markers 2.5, 3.5 13–33 0.014 ID: 0.0165, 0.017
Terumo Neuro LVIS Intraluminal Support Device Nitinol with tantalum markers 3.5, 4, 4.5, 5.5 12–33 0.014 ID: 0.021

Wires / Hydrophilic Guidewires

View Chart
Company Name Product Name Type Diameter (inch) Length (cm) Tip Type Comments
Terumo Neuro Traxcess Guidewire Hybrid nitinol/stainless steel construction with hydrophilic coating 0.012; 0.014 (proximal) 200 Soft, atraumatic tip; shapeable 1.4-cm tip length; straight with 0.012-inch distal diameter to access small vessels –
Terumo Neuro Traxcess Docking Wire Docking wire 0.014 115 – Compatible with Traxcess guidewire
Terumo Neuro Traxcess 7 Mini Hydrophilic guidewire 0.007 210 Soft 0.007-inch tip tapers to 0.014-inch guidewire body
Terumo Neuro Headliner Guidewire Guidewire with Terumo Glide technology hydrophilic coating 0.012, 0.016 200 45°, 90° angle; 90°/150° double angle; 1.5-mm J-tip angle; tip flexibility: 20, 35 cm Proprietary Glidewire technology with gold coil at tip for enhanced radiopacity; distal tip specifically engineered for delicate neuro procedures; floppy and standard tip taper available

Other Devices / Thrombus Aspiration Devices

View Chart
Company Name Product Name Type Maximum Tip Diameter (mm) Minimum Guide Catheter Size (F) Catheter Length (cm)
Terumo Neuro Sofia Flow Plus Aspiration catheter Distal OD: 2.1; ID: 0.070 inch 6 125, 131

Embolization / Intrasaccular Flow Disruptor

View Chart
Company Name Product Name Materials Used Device Diameter (mm) Device Height (mm)
Terumo Neuro WEB Aneurysm Embolization System—Single Layer Sphere Nitinol-platinum 4–11 2.6–9.6
Terumo Neuro WEB Aneurysm Embolization System—Single Layer Nitinol-platinum 4–11 3–9

Other Devices / Flow Diverters

View Chart
Company Name Product Name Stent Diameter (mm) Stent Length (mm) Recommended Guide Catheter Size (inch) Materials Used
Terumo Neuro FRED (Flow Re-Direction Endoluminal Device) 2.5, 3, 3.5, 4, 4.5, 5, 5.5 13–45 Headway 21 (2.5–3 mm devices); Headway 27 (3.5–5.5 mm devices) Nitinol wire braid with tantalum helix for visibility

Catheters / Microcatheters

View Chart
Company Name Product Name Type of Catheter Construction Proximal Size (F) Middle Size (F) Distal Size (F) Catheter Working Length (cm) Catheter Endhole Diameter ID (inch) Recommended Guidewire Size (inch) Radiopaque Tip (Yes/No) Hydrophilic Coating (Yes/No)
Terumo Neuro Headway 17 Distal shaft provides support for coiling while the segmented design provides smooth trackability 2.4 – 1.7 150 0.017 0.014 Yes Yes
Terumo Neuro Headway 21 Coil reinforced catheter with multisegmented design 2.5 – 2 156 0.021 0.014 Yes Yes
Terumo Neuro Headway 27 Coil reinforced catheter with multisegmented design 3.1 – 2.6 156 0.027 0.014 Yes Yes
Terumo Neuro Headway DUO Hybrid braid and coil design 2.1 – 1.3, 1.6 167, 156 0.013, 0.0165 – Yes Yes
Terumo Neuro VIA Designed for precise delivery, deployment, and retrieval of the WEB device 2.8, 3.2, 3.8 – 2.5, 3, 3.4 154, 154, 133 0.021, 0.027, 0.033 0.014 Yes Yes
Terumo Neuro Wedge Coil reinforcement and distal bulb 2.5 – 2 1.5 (distal length) 0.021 0.014 Yes Yes

More Categories:

Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View All

Advertisement

Latest News


May 4, 2026

ENGULF Analysis Shows Reduced Blood Loss With E2’s Hēlo System in PE Procedures

May 1, 2026

FDA Awards IDE for Pivotal Study of enVVeno’s Venous Valve to Treat Severe Deep CVI

April 29, 2026

Cydar Maps Planning and Navigation Solution Expanded to Enable Use in Complex Branched and Visceral Cases

Most Read Articles


Update on Modern Complex Abdominal Aortic Repair Options

With Jason T. Lee, MD; Steven Maximus, MD, FACS; Gustavo Oderich, MD, FACS; Benjamin W. Starnes, MD, FACS; Carlos Timaran, MD; Kak Khee Yeung, MD, PhD, FEBVS; and Javairiah Fatima, MD, FACS, DFSVS

A Private Practice Physician’s Experience Treating Chronic Venous Insufficiency

By Robert A. Edwards, DO

Addressing Pelvic Venous Disease With a New Class of Coils

With Gloria Salazar, MD, FSIR; Ronald Winokur, MD, FSIR, RPVI; Marissa Famularo, DO; Eric Hager, MD; Driss Raissi, MD, MBA, FSIR; and Brian Do, DO

Back to Top
Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous
Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

News• Current Issue• Archive• Device Guide• Advertising• About Calendar• Contact• Privacy• Submissions• Subscriptions


Endovascular Today (ISSN 1551-1944 print and ISSN 2689-792X online) is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field.



magazine Created with Sketch.

Free Print Subscriptions

Fill 1 Created with Sketch.