Group 7 Copy 3 Created with Sketch.
News Issue Archive Device Guide Calendar Subscribe Advertising

MENU

Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

News Current Issue Archive Device Guide Calendar Subscribe Advertising About Contact Privacy Submissions
Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

Back to Top

Advertisement

Advertisement

US Company Directory


Asahi Intecc USA, Inc.

2500 Red Hill Ave., Suite 210, Santa Ana, CA 92705

PHONE: (949) 756-8901 | FAX: (949) 756-8165

down-arrow Created with Sketch.
down-arrow Created with Sketch.

Catheters / Guiding Catheters

View Chart
Company Name Product Name Type Size (F) Length (cm) Internal Diameter (inch) Radiopaque Tip (Yes/No) Hydrophilic Coated
Asahi Intecc USA, Inc. Asahi Sheathless Eaucath JL, JR, Amplatz, Power Backup, multipurpose 6.5, 7.5 100 0.070, 0.081 Yes Yes
Asahi Intecc USA, Inc. Asahi Fubuki Stainless steel braiding 6, 7, 8 80, 90, 100, 110 0.071, 0.081, 0.090 Yes Yes, 15 cm (5 cm on 8 F)

Advertisement

Advertisement

Catheters / Specialty Catheters

View Chart
Company Name Product Name Catheter Size (F) Working Length (cm) Minimum Guiding Catheter ID (inch) Comments
Asahi Intecc USA, Inc. Asahi Corsair Armet 2.5 60, 90, 135, 150 0.017 Stainless steel braided catheter with increased support and a durable metal tip for use in the peripheral vasculature
Asahi Intecc USA, Inc. Asahi Fubuki 4.2-F Distal Support System 4.2 (ID: 0.043 inch) 120, 125, 130 6 F Suitable for triaxial system
Asahi Intecc USA, Inc. Tornus Specialty Catheter 2.1, 2.6 135 – The specialty catheter, with its threaded stainless steel construction, enables the exchange and support required for treating chronically stenosed lesions

Wires / Coiled Stainless Steel Guidewires

View Chart
Company Name Product Name Type Diameter (inch) Length (cm) Tip Type Antithrombogenic Comments
Asahi Intecc USA, Inc. Asahi Chikai 10 Stainless steel Actone structure 0.010 200, 300 Straight – Neurointervention
Asahi Intecc USA, Inc. Asahi Chikai V Stainless steel Actone structure 0.014 165 Straight – Interventional radiology procedures
Asahi Intecc USA, Inc. Asahi Chikai 008 Stainless steel Actone structure 0.010, 0.008 200 Straight – Neurointervention
Asahi Intecc USA, Inc. Asahi Chikai Stainless steel Actone structure 0.014 200, 300 Straight and round curve – Neurointervention

Wires / Hydrophilic Guidewires

View Chart
Company Name Product Name Type Diameter (inch) Length (cm) Tip Type Comments
Asahi Intecc USA, Inc. Asahi Gladius Mongo 18 PV ES Stainless steel with a polymer jacket and hydrophilic coating 0.018 190, 300 3-gf tip load, straight, preshape A workhorse polymer-jacketed guidewire with high steerability, good support, and the ability to form a narrow loop for crossing and treating stenosed lesions
Asahi Intecc USA, Inc. Asahi Gladius 0.018 Stainless steel with hydrophilic coating 0.018 200, 300 4-gf tip load, straight A workhorse polymer-jacketed guidewire with ACT ONE technology for superior maneuverability and durability in a broad range of cases
Asahi Intecc USA, Inc. Asahi Gladius Mongo ES Stainless steel with polymer jacket and hydrophilic coating 0.014 190, 300 3-gf tip load, straight, preshape A workhorse polymer-jacketed guidewire with high steerability, good support, and the ability to form a narrow loop for crossing and treating stenosed lesions
Asahi Intecc USA, Inc. Treasure Floppy 0.018 Stainless steel with hydrophilic coating 0.018 190, 300 4-gf tip load, straight Workhorse guidewire for nontotally occluded lesions
Asahi Intecc USA, Inc. Treasure 12 Stainless steel with hydrophilic coating 0.018 180, 300 12-gf tip load, straight A specialty guidewire for controlled drilling when targeting highly stenosed, calcified lesions
Asahi Intecc USA, Inc. Astato XS 40 Stainless steel with tapered tip and hydrophilic coating 0.014 200, 300 40-gf tip load, straight A specialty guidewire with tapered tip and high tip load for crossing complex lesions with heavy calcification and/or tough fibrous tissue
Asahi Intecc USA, Inc. Astato XS 20 Stainless steel with a tapered tip and hydrophilic coating 0.014 180, 300 20-gf tip load, straight A specialty guidewire with tapered tip for crossing complex lesions with heavy calcification and/or tough fibrous tissue
Asahi Intecc USA, Inc. Astato 30 Stainless steel with hydrophilic coating 0.018 180, 300 30-gf tip load, straight A specialty guidewire with tapered tip for crossing complex lesions with heavy calcification and/or tough fibrous tissue
Asahi Intecc USA, Inc. Asahi Regalia XS 1.0 Stainless steel with a polymer jacket and hydrophilic coating 0.014 180, 300 1-gf tip load, straight A soft polymer guidewire with flexible shaft for trackability in tight lesions and difficult anatomy
Asahi Intecc USA, Inc. Asahi Meister 16 Stainless steel Actone structure 0.016 165, 180 45° angle/round curve/double angle Interventional radiology procedure
Asahi Intecc USA, Inc. CrossLead 0.035 Nitinol with a polymer jacket and hydrophilic coating 0.035 200, 300 Angled A multipurpose nitinol guide wire with shapeable tip and narrow looping technology for sheath delivery, lesion crossing and device delivery in difficult anatomy and complex lesions
Asahi Intecc USA, Inc. Asahi Halberd 0.018 Stainless steel with hydrophilic coating 0.018 200, 300 12-gf tip load, straight A specialty guide wire with ACT ONE technology for superior directional control and effective lesion engagement
Asahi Intecc USA, Inc. Asahi Gladius 0.014 Stainless steel with polymer jacket and hydrophilic coating 0.014 200, 300 3-gf tip load, straight A workhorse polymer-jacketed guidewire with ACT ONE technology for superior maneuverability and durability in a broad range of cases
Asahi Intecc USA, Inc. Asahi Gaia PV Stainless steel with hydrophilic coating 0.018 200, 300 7.5-gf tip load, preshaped A tapered guidewire with micro cone tip and ACT ONE technology for effective navigation, ease of advancement, and good penetration
Asahi Intecc USA, Inc. Asahi Chikai V Stainless steel with hydrophilic coating 0.014 165 Straight Designed for super selective embolization; Actone, dual-coil, provides exceptional torque response and durable tip-shape retention for distal branch and multiple vessel embolization
Asahi Intecc USA, Inc. Asahi Chikai black 18 Stainless steel Actone structure 0.016, 0.018 (reverse taper) 200 Round curve Neurointervention
Asahi Intecc USA, Inc. Asahi Chikai black Stainless steel Actone structure 0.014 200 Round curve/90° angle Neurointervention
Asahi Intecc USA, Inc. Asahi Chikai 10 Stainless steel with hydrophilic coating 0.010 200, 300 Straight Designed as workhorse guidewire for neurointerventional procedures; Actone, dual-coil, provides exceptional torque response and durable tip-shape retention; designed with optimum balance between tip flexibility and microcatheter support
Asahi Intecc USA, Inc. Asahi Chikai Stainless steel with hydrophilic coating 0.014 200, 300 Straight Designed as workhorse guidewire for neurointerventional procedures; Actone, dual-coil, provides exceptional torque response and durable tip-shape retention; designed with optimum balance between tip flexibility and microcatheter support
Asahi Intecc USA, Inc. Asahi Halberd 0.014 Stainless steel with hydrophilic coating 0.014 200, 300 12-gf tip load, straight A specialty guidewire with ACT ONE technology for superior directional control and effective lesion engagement

Wires / Mandril/Specialty Guidewires

View Chart
Company Name Product Name Type Diameter (inch) Length (cm) Tip Type Coating Type Comments
Asahi Intecc USA, Inc. Asahi Treasure 12 Stainless steel 0.018 180, 300 Straight Hydrophilic; uncoated tip Percutaneous transluminal angioplasty
Asahi Intecc USA, Inc. Asahi Sion black Polymer jacket 0.014 190, 300 Straight, J, Preshape Polymer jacket with hydrophilic coating Stainless steel core with Act One structure
Asahi Intecc USA, Inc. Asahi Halberd Stainless steel with Act One structure 0.014, 0.018 200, 300 Straight/preshaped Hydrophilic; uncoated tip Percutaneous transluminal angioplasty
Asahi Intecc USA, Inc. Asahi Gaia PV Stainless steel with Act One structure 0.018 200, 300 Straight/preshaped Hydrophilic; uncoated tip Percutaneous transluminal angioplasty
Asahi Intecc USA, Inc. Asahi Astato XS 40 Stainless steel 0.008, 0.014 180, 300 Straight Hydrophilic; uncoated tip Percutaneous transluminal angioplasty
Asahi Intecc USA, Inc. Asahi Astato XS 20 Stainless steel 0.009, 0.014 180, 300 Straight Hydrophilic; uncoated tip Percutaneous transluminal angioplasty
Asahi Intecc USA, Inc. Asahi Astato 30 Stainless steel 0.018 180, 300 Straight Hydrophilic; uncoated tip Percutaneous transluminal angioplasty

Catheters / Microcatheters

View Chart
Company Name Product Name Type of Catheter Construction Proximal Size (F) Middle Size (F) Distal Size (F) Catheter Working Length (cm) Catheter Endhole Diameter ID (inch) Recommended Guidewire Size (inch) Radiopaque Tip (Yes/No) Hydrophilic Coating (Yes/No)
Asahi Intecc USA, Inc. Asahi Caravel Stainless steel braided 2.6 1.9 1.4 135, 150 – 0.014 Yes, tungsten powder 5-mm tip Yes
Asahi Intecc USA, Inc. Asahi Corsair Stainless steel braided 2.8 2.6 1.3 135, 150 0.015 0.014 Yes, tungsten powder 5-mm tip Yes
Asahi Intecc USA, Inc. Asahi Corsair Pro Stainless steel braided 2.8 2.6 1.3 135, 150 0.015 0.014 Yes, tungsten powder 5-mm tip Yes

More Categories:

Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View All

Advertisement

Latest News


May 4, 2026

ENGULF Analysis Shows Reduced Blood Loss With E2’s Hēlo System in PE Procedures

May 1, 2026

FDA Awards IDE for Pivotal Study of enVVeno’s Venous Valve to Treat Severe Deep CVI

April 29, 2026

Cydar Maps Planning and Navigation Solution Expanded to Enable Use in Complex Branched and Visceral Cases

Most Read Articles


Update on Modern Complex Abdominal Aortic Repair Options

With Jason T. Lee, MD; Steven Maximus, MD, FACS; Gustavo Oderich, MD, FACS; Benjamin W. Starnes, MD, FACS; Carlos Timaran, MD; Kak Khee Yeung, MD, PhD, FEBVS; and Javairiah Fatima, MD, FACS, DFSVS

A Private Practice Physician’s Experience Treating Chronic Venous Insufficiency

By Robert A. Edwards, DO

Addressing Pelvic Venous Disease With a New Class of Coils

With Gloria Salazar, MD, FSIR; Ronald Winokur, MD, FSIR, RPVI; Marissa Famularo, DO; Eric Hager, MD; Driss Raissi, MD, MBA, FSIR; and Brian Do, DO

Back to Top
Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous
Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

News• Current Issue• Archive• Device Guide• Advertising• About Calendar• Contact• Privacy• Submissions• Subscriptions


Endovascular Today (ISSN 1551-1944 print and ISSN 2689-792X online) is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field.



magazine Created with Sketch.

Free Print Subscriptions

Fill 1 Created with Sketch.

Email Newsletter



twitter-icon LinkedIn Created with Sketch. instagram BlueSky-Circle
Cardiac Interventions Today
Group 7 Copy 3 Created with Sketch.
bmc-secondary-mark-color copy Created with Sketch.

© 2026 Bryn Mawr Communications II, LLC.  
All Rights Reserved   •   Privacy Policy

one-trust-button