Advertisement
Advertisement
Transit Scientific
159 W Broadway #200, Salt Lake City, UT 84101
PHONE:
Balloons / PTA Balloons
View Chart| Company Name | Product Name | Nominal Pressure (atm) | Rated Burst Pressure (atm) | Guidewire Compatibility (inch) | Shaft Length (cm) | Sheath Compatibility (F) | Balloon Diameters (mm) | Balloon Lengths (cm) |
|---|---|---|---|---|---|---|---|---|
| Transit Scientific | XO Score D25 Sheath (0.25-mm Scoring Depth) | Dependent on nominal pressure of balloon used | Dependent on rated burst pressure of balloon used | 0.014, 0.018, 0.035 | 65, 125 | 7 | 4, 5, 6, 7, 8 | 2, 3, 4 |
| Transit Scientific | XO Score Low Profile RX 2.2F Device (0.15-mm Scoring Depth) | Dependent on nominal pressure of balloon used with the device | Dependent on rated burst pressure of balloon used with the device | 0.014 | 150 | 1 F size larger than the PTA balloon labeling | 1.5–4.0 | 20–200 mm |
| Transit Scientific | XO Score Low Profile RX 3.8F Device (0.20-mm Scoring Depth) | Dependent on nominal pressure of balloon used with the device | Dependent on rated burst pressure of balloon used with the device | 0.014, 0.018 | 150 | 1 F size larger than the PTA balloon labeling | 3.0–7.0 | 20–200 mm |
| Transit Scientific | XO Constrain 2.2F Catheter | Dependent on nominal pressure of PTA/PTCA used | Dependent on burst pressure of PTA/PTCA used | 0.014 | 145 | 1 F size larger than PTA/PTCA balloon labeling | 1.5–4 | 6–20 mm |
Advertisement
Advertisement
Balloons / Specialty Balloons
View Chart| Company Name | Product Name | Nominal Pressure (atm) | Rated Burst Pressure (atm) | Guidewire Compatibility (inch) | Size (F) | Sheath Compatibility (F) | Shaft Length (cm) | Balloon Diameters (mm) | Balloon Lengths (cm) |
|---|---|---|---|---|---|---|---|---|---|
| Transit Scientific | XO Score Sheath | Dependent on nominal pressure of balloon used | Dependent on rated burst pressure of balloon used | 0.014, 0.018, 0.035 | 6.4 | 7 | 65, 125 | 4, 5, 6, 7, 8 | 2, 3, 4 |
| Transit Scientific | XO Score Low Profile RX Device (0.15-mm Scoring Depth) | Dependent on nominal pressure of balloon used with the device | Dependent on rated burst pressure of balloon used with the device | 0.014 | 2.2 | 1 F size larger than the PTA balloon labeling | 150 | 1.5–4 | 20–200 mm |
| Transit Scientific | XO Score Low Profile RX Device (0.20-mm Scoring Depth) | Dependent on nominal pressure of balloon used with the device | Dependent on rated burst pressure of balloon used | 0.014, 0.018 | 3.8 | 1 F size larger than the PTA balloon labeling | 150 | 3–7 | 20–200 mm |
| Transit Scientific | XO Constrain 2.2F Catheter | Dependent on nominal pressure of PTA/PTCA used | Dependent on burst pressure of PTA/PTCA used | 0.014 | 2.2 | 1 F size larger than PTA/PTCA balloon labeling | 145 | 1.5–4 | 6–20 mm |
Catheters / Microcatheters
View Chart| Company Name | Product Name | Type of Catheter Construction | Proximal Size (F) | Middle Size (F) | Distal Size (F) | Catheter Working Length (cm) | Catheter Endhole Diameter ID (inch) | Recommended Guidewire Size (inch) | Radiopaque Tip (Yes/No) | Hydrophilic Coating (Yes/No) |
|---|---|---|---|---|---|---|---|---|---|---|
| Transit Scientific | XO Cross 14 Microcatheter | Metal exoskeleton with outer polymer layer | 2 | 2 | 1.6 | 90, 135, 150, 175 | 0.018 | 0.014 | Yes | No |
| Transit Scientific | XO Cross 14 Microcatheter With Hydrophilic Coating | Metal exoskeleton with outer polymer layer and hydrophilic coating | 2 | 2 | 1.6 | 90, 135, 150, 175 | 0.018 | 0.014 | Yes | Yes |
| Transit Scientific | XO Cross 18 Microcatheter | Metal exoskeleton with outer polymer layer | 2.6 | 2.6 | 1.9 | 90, 135, 150 | 0.021 | 0.014, 0.018 | Yes | No |
| Transit Scientific | XO Cross 18 Microcatheter With Hydrophilic Coating | Metal exoskeleton with outer polymer layer and hydrophilic coating | 2.6 | 2.6 | 1.9 | 90, 135, 150 | 0.021 | 0.014, 0.018 | Yes | Yes |
| Transit Scientific | XO Cross 35 Support Catheter | Metal exoskeleton with outer polymer layer | 3.9 | 3.9 | 3.2 | 90, 135, 150, 175 | 0.038 | 0.014, 0.018, 0.035 | Yes | No |
| Transit Scientific | XO Cross 35 Support Catheter With Hydrophilic Coating | Metal exoskeleton with outer polymer layer and hydrophilic coating | 3.9 | 3.9 | 3.2 | 90, 135, 150, 175 | 0.038 | 0.014, 0.018, 0.035 | Yes | Yes |
| Transit Scientific | XO Cath 2.0F Microcatheter | Laser cut metal hypotube with hydrophilic coating and PTFE liner | 2.6 | – | 2 | 90, 110, 130, 150, 175, 220 | 0.021 | 0.014, 0.018 | Yes, 2 radiopaque markerbands | Yes |
| Transit Scientific | XO Cath 2.6F Microcatheter | Laser cut metal hypotube with hydrophilic coating and PTFE liner | 2.8 | – | 2.6 | 90, 110, 130, 150, 175, 220 | 0.027 | 0.014, 0.018, 0.021 | Yes, 2 radiopaque markerbands | Yes |
More Categories:
Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View AllAdvertisement