Company Name Product Name Type (Detachable, Pushable) Material Coil Diameter (mm) Coil Length (cm) Recommended Delivery Catheter Sizes (ID) (inch) US FDA Indicated Use
Terumo Interventional Systems Azur CX Peripheral Coil Detachable .018 System Detachable Platinum and hydrogel 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 2, 4, 8, 13, 16, 20, 24, 28, 32, 34, 36, 38, 39, 40 0.019–0.027 Arterial and venous vessel embolization in the peripheral vasculature
Terumo Interventional Systems Azur CX Peripheral Coil Detachable .035 System Detachable Platinum and hydrogel 4, 5, 6, 8, 10, 13, 16, 20 7, 9, 11, 12, 17, 19, 24, 32, 39 0.038–0.047 Intended to reduce or block the rate of blood flow in vessels of the peripheral vasculature; it is intended for use in the interventional radiologic management of AVMs, AVFs, aneurysms, and other lesions of the peripheral vasculature
Terumo Interventional Systems Azur Peripheral Framing Coil Embolization Detachable .018 System Detachable Platinum 8, 10, 14, 20 20, 26, 34, 50 0.021–0.027 Arterial and venous vessel embolization in the peripheral vasculature
Terumo Interventional Systems Azur Peripheral Framing Coil Embolization Detachable .035 System Detachable Platinum 8, 10, 14, 20 20, 26, 34, 50 0.038–0.047 Arterial and venous vessel embolization in the peripheral vasculature
Terumo Interventional Systems Azur Peripheral HydroCoil Embolization Detachable .018 System Detachable Platinum and hydrogel 2, 3, 4, 5, 6, 8, 10, 12, 15, 20 2, 4, 5, 10, 15, 20, 30 0.021–0.027 Arterial and venous vessel embolization in the peripheral vasculature
Terumo Interventional Systems Azur Peripheral HydroCoil Embolization Detachable .035 System Detachable Platinum and hydrogel 4, 6, 8, 10, 12, 15, 20 5, 10, 15, 20, 30 0.038–0.047 Arterial and venous vessel embolization in the peripheral vasculature
Terumo Interventional Systems Azur Peripheral HydroCoil Embolization Pushable .018 System Pushable Platinum and hydrogel 2, 3, 4, 5, 6, 8, 10 2, 4, 6, 10, 14, 20 0.021–0.027 Arterial and venous vessel embolization in the peripheral vasculature
Terumo Interventional Systems Azur Peripheral HydroCoil Embolization Pushable .035 System Pushable Platinum and hydrogel 4, 5, 6, 8, 10, 15 4, 6, 10, 14, 20 0.038–0.047 Arterial and venous vessel embolization in the peripheral vasculature
Blockade Medical, a Balt Company Barricade Coil System Detachable Bare platinum 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15 1–50 0.017–0.021 Intended for the endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as AVMs and AVFs; it is also intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature
Boston Scientific Corporation Complex Helical-18 Fibered Platinum Coils Pushable Platinum tungsten alloy 4, 6, 7, 8, 10, 11 2, 3, 4, 5, 6, 7 0.021 0.018-inch fibered platinum coils are intended for arterial and venous embolizations in the peripheral vasculature
Medtronic Concerto Nylon Fibered Helical Coils Detachable 2 4, 6, 8 0.017 Indicated for arterial and venous embolizations in the peripheral vasculature
Medtronic Concerto Nylon Fibered Helical Coils Detachable 3 4, 8 0.017 Indicated for arterial and venous embolizations in the peripheral vasculature
Medtronic Concerto Nylon Fibered Helical Coils Detachable 4 8, 10 0.017 Indicated for arterial and venous embolizations in the peripheral vasculature
Medtronic Concerto Nylon Fibered Helical Coils Detachable 5 15, 20 0.021 Indicated for arterial and venous embolizations in the peripheral vasculature
Medtronic Concerto Nylon Fibered Helical Coils Detachable 6 20 0.021 Indicated for arterial and venous embolizations in the peripheral vasculature
Medtronic Concerto Nylon Fibered Helical Coils Detachable 7, 8, 9, 10 30 0.021 Indicated for arterial and venous embolizations in the peripheral vasculature
Medtronic Concerto PGLA Fibered 3D Coils Detachable 2 2, 4, 6 0.017 Indicated for arterial and venous embolizations in the peripheral vasculature
Medtronic Concerto PGLA Fibered 3D Coils Detachable 3 4, 6, 8 0.017 Indicated for arterial and venous embolizations in the peripheral vasculature
Medtronic Concerto PGLA Fibered 3D Coils Detachable 4 8, 10, 12 0.017 Indicated for arterial and venous embolizations in the peripheral vasculature
Medtronic Concerto PGLA Fibered 3D Coils Detachable 5 15 0.017 Indicated for arterial and venous embolizations in the peripheral vasculature
Medtronic Concerto PGLA Fibered 3D Coils Detachable 6 20 0.017 Indicated for arterial and venous embolizations in the peripheral vasculature
Medtronic Concerto PGLA Fibered 3D Coils Detachable 7, 8, 9, 10 30 0.017 Indicated for arterial and venous embolizations in the peripheral vasculature
Medtronic Concerto PGLA Fibered 3D Coils Detachable 12, 14, 16, 18 40 0.021 Indicated for arterial and venous embolizations in the peripheral vasculature
Medtronic Concerto PGLA Fibered Helical Coils Detachable 12, 14 30 0.021 Indicated for arterial and venous embolizations in the peripheral vasculature
Medtronic Concerto PGLA Fibered Helical Coils Detachable 16, 18 40 0.021 Indicated for arterial and venous embolizations in the peripheral vasculature
Medtronic Concerto PGLA Fibered Helical Coils Detachable 20 50 0.021 Indicated for arterial and venous embolizations in the peripheral vasculature
Spartan Micro, Inc. eCoil—Megalo Detachable (mechanical) Platinum 3–25 5.5–50 0.017 Indicated for arterial and venous embolizations in the peripheral vasculature
Boston Scientific Corporation Figure 8-18 Fibered Platinum Coils Pushable Platinum tungsten alloy 2 1 0.021 0.018-inch fibered platinum coils are intended for arterial and venous embolizations in the peripheral vasculature
Cook Medical Hilal Embolization Microcoil Pushable Platinum Straight to 5 0.5–3 0.018 Embolization of selective vessel supply to AVMs and other vascular lesions of the brain, spinal cord, and spine
Boston Scientific Corporation IDC Soft Interlocking Detachable Coil Detachable Platinum tungsten alloy 2, 3, 4, 5 2, 4, 6, 8, 10, 12 0.021 Indicated to obstruct or reduce blood flow in the peripheral vasculature; the device is not intended for neurovascular use
Boston Scientific Corporation Interlock-18 Fibered IDC Occlusion System Detachable Platinum tungsten alloy 2, 3, 4, 5, 6, 8, 10, 12, 14, 18, 20, 22 2.3, 4, 4.1, 5, 5.8, 6, 8, 10, 12, 15, 20, 30, 50, 60 0.021 Indicated to obstruct or reduce blood flow in the peripheral vasculature; the device is not intended for neurovascular use
Boston Scientific Corporation Interlock-35 Fibered IDC Occlusion System Detachable Platinum tungsten alloy 3, 4, 6, 8, 10, 12, 15, 18, 20 4, 4.5, 6, 9, 10, 14, 20, 25, 30, 40 5-F Imager II selective diagnostic catheter (0.035 or 0.038 inch ID) Indicated to obstruct or reduce blood flow in the peripheral vasculature; the device is not intended for neurovascular use
Cook Medical MReye Embolization Coil Pushable Inconel 2, 3, 5, 8, 10, 12, 14, 15, 20, 25, 30, 45 2, 3, 4, 5, 8, 10, 12, 15, 16 0.035, 0.038 Arterial and venous embolization in the peripheral vasculature
Boston Scientific Corporation Multi-Loop-18 Fibered Platinum Coils Pushable Platinum tungsten alloy 4 3 0.021 0.018-inch fibered platinum coils are intended for arterial and venous embolizations in the peripheral vasculature
Boston Scientific Corporation Multi-Loop-35 Fibered Platinum Coils Pushable Platinum tungsten alloy 3, 4, 5, 6, 7, 9 2, 3, 4, 5, 6 0.035 For arterial and venous embolization in the peripheral vasculature
Cook Medical Nester Embolization Coil Pushable Platinum 4, 6, 8, 10, 12, 14, 16, 18, 20 7, 14, 20 0.035 Arterial and venous embolization in the peripheral vasculature
Cook Medical Nester Embolization Microcoil Pushable Platinum 2, 3, 4, 5, 6, 8, 10 3, 5, 7, 14 0.018 Arterial and venous embolization in the peripheral vasculature
Penumbra, Inc. (Peripheral Vascular) Packing Coil Detachable Platinum Wave shape conforms to vessel diameter 5, 15, 30, 45, 60 0.025–0.027 high-flow microcatheters (Lantern) Indicated for the embolization of intracranial aneurysms, other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistula, and arterial and venous embolizations in the peripheral vasculature
Penumbra, Inc. (Peripheral Vascular) POD Detachable with dedicated anchor segment for high flow vessel sacrifice Platinum 3, 4, 5, 6, 8, 10, 12, 14 20–60 0.025–0.027 high-flow microcatheters (Lantern) For coils with nominal sizes ≤ 6 mm: indicated for the embolization of intracranial aneurysms, other neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistula, arterial and venous embolizations in the peripheral vasculature; for coils with nominal sizes > 6 mm: indicated for arterial and venous embolizations in the peripheral vasculature
Cook Medical Retracta Detachable Embolization Coil Detachable Platinum 4, 6, 8, 10, 12, 14, 16, 18, 20 7, 14 0.035 Arterial and venous embolization in the peripheral vasculature
Penumbra, Inc. (Peripheral Vascular) Ruby Coil Detachable Platinum 2–40 (3D complex shape, multiple softness levels) 1–60 0.025–0.027 high-flow microcatheters (Lantern) Arterial and venous vessel embolization in the peripheral vasculature
Boston Scientific Corporation Straight-18 Fibered Platinum Coils Pushable Platinum tungsten alloy Straight 0.2, 0.5 0.021 0.018-inch fibered platinum coils are intended for arterial and venous embolizations in the peripheral vasculature
Cook Medical Tornado Embolization Coil Pushable Platinum 4–3, 5–3, 6–3, 7–3, 8–4, 8–5, 10–4, 10–5 2.6–12.5 0.035 Arterial and venous embolization in the peripheral vasculature
Cook Medical Tornado Embolization Microcoil Pushable Platinum 3–2, 4–2, 5–2, 6–2, 7–3, 8–4, 10–4 2–14.2 0.018 Arterial and venous embolization in the peripheral vasculature
Codman Neuro (Johnson & Johnson) Trufill Pushable Coils Pushable Platinum with nylon fibers 3, 4, 5, 6, 7, 10 2–10 0.021 To reduce or block the rate of blood flow in vessels of the peripheral and neurovasculature; they are intended for use in the interventional radiologic management of AVMs, AVFs, and other vascular lesions of the spinal cord and spine
Boston Scientific Corporation VortX Diamond-18 Fibered Platinum Coils Pushable Platinum tungsten alloy 3, 4, 5, 6 2.3, 4.1, 5.8, 8 0.021 0.018-inch fibered platinum coils are intended for arterial and venous embolizations in the peripheral vasculature
Boston Scientific Corporation VortX-18 Fibered Platinum Coils Pushable Platinum tungsten alloy 3, 4, 5, 6 2.2, 4.2, 6, 8.5 0.021 0.018-inch fibered platinum coils are intended for arterial and venous embolizations in the peripheral vasculature
Boston Scientific Corporation VortX-35 Fibered Platinum Coils Pushable Platinum tungsten alloy 4, 5, 6, 7 3, 3.5, 5.3, 6.7 0.035 For arterial and venous embolization in the peripheral vasculature

Advertisement