Group 7 Copy 3 Created with Sketch.
News Issue Archive Device Guide Calendar Subscribe Advertising

MENU

Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

News Current Issue Archive Device Guide Calendar Subscribe Advertising About Contact Privacy Submissions
Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

Back to Top

Advertisement

Advertisement

EURO Company Directory


Teleflex

3015 Carrington Mill Boulevard, Morrisville, NC 27560

PHONE: (866) 246-6990 | FAX: (866) 804-9881

down-arrow Created with Sketch.
down-arrow Created with Sketch.

Balloons / Drug-Coated Balloons

View Chart
Company Name Product Name Drug Type Drug Concentration (µg/mm2) Excipient Type Guidewire Compatibility (inch) Shaft Length (cm) Sheath Compatibility (F) Balloon Diameters (mm) Balloon Lengths (cm)
Teleflex Passeo-18 Lux Paclitaxel 3 Butyryl-tri-hexyl citrate 0.018 90, 130; 150 (2-mm diameter only) 4 (2–4 mm), 5 (5–7 mm) 2, 2.5, 3, 4, 5, 6, 7 4, 8, 12

Advertisement

Advertisement

Balloons / PTA Balloons

View Chart
Company Name Product Name Nominal Pressure (atm) Rated Burst Pressure (atm) Guidewire Compatibility (inch) Shaft Length (cm) Sheath Compatibility (F) Balloon Diameters (mm) Balloon Lengths (cm)
Teleflex Oscar Peripheral Multifunctional Catheter 8 14 (ø 3.5 mm), 16 (ø 2, 2.5, 3 mm) 0.014 127 4 (only to be used with the matching Oscar Peripheral Multifunctional Support Catheter system) 2, 2.5, 3, 3.5 Variable from 2–18
Teleflex Oscar Peripheral Multifunctional Catheter 6 12 (ø 7 mm), 14 (ø 4, 5, 6 mm) 0.018 72 (ø 7 mm), 80, 128 6 (only to be used with the matching Oscar Peripheral Multifunctional Support Catheter system) 4, 5, 6, 7 Variable from 2–10 (ø 7 mm), 2–18
Teleflex Passeo-14 7 14 0.014 90, 120, 150 4 1.5, 2, 2.5, 3, 3.5, 4 2, 4, 7, 10, 14, 18, 22
Teleflex Passeo-18 6 12–15 0.018 90, 130, 150 4–5 2, 2.5, 3, 3.5, 4, 5, 6, 7 2, 4, 6, 8, 12, 15, 17, 20
Teleflex Passeo-35 7 12–20 0.035 80, 130 5–6 3, 4, 5, 6, 7, 8, 9, 10 2, 4, 6, 8, 10, 12, 15, 17, 20
Teleflex Passeo-35 HP 12, 14 18–27 0.035 40, 75 6, 7, 8 3, 4, 5, 6, 7, 8, 9, 10, 12 2, 4, 6, 8, 10
Teleflex Passeo-35 Xeo 8, 9 10–21 0.035 90, 130, 170 5–7 3, 4, 5, 6, 7, 8, 9, 10, 12 2, 4, 6, 8, 10, 12, 15, 17, 20, 25

Balloons / Specialty Balloons

View Chart
Company Name Product Name Nominal Pressure (atm) Rated Burst Pressure (atm) Guidewire Compatibility (inch) Size (F) Sheath Compatibility (F) Shaft Length (cm) Balloon Diameters (mm) Balloon Lengths (cm)
Teleflex Oscar Peripheral Multifunctional Catheter 6 (4–7 mm); 8 (2–3.5 mm) 12 (7 mm); 14 (3.5–6 mm); 16 (2–4 mm) 0.014 (2–3.5 mm); 0.018 (4–7 mm) 4 (2–3.5 mm); 6 (4–7 mm) 4 (2–3.5 mm); 6 (4–7 mm) 80, 128 2, 2.5, 3, 3.5, 4, 5, 6, 7 2–18 (length-adjustable)

Catheters / Microcatheters

View Chart
Company Name Product Name Type of Catheter Construction Proximal Size (F) Middle Size (F) Distal Size (F) Catheter Working Length (cm) Catheter Endhole Diameter ID (inch) Recommended Guidewire Size (inch) Radiopaque Tip (Yes/No) Hydrophilic Coating (Yes/No)
Teleflex Turnpike LP Catheter Hybrid multilayer: dual bidirectional coils with inner braid 2.9 2.2 1.6 135, 150 0.0165 0.014 Yes, tungsten-loaded tip Yes
Teleflex Turnpike Spiral Catheter Hybrid multilayer: dual bidirectional coils with inner braid and external nylon spiral coil 2.9 2.9 1.6 135, 150 0.0165 0.014 Yes, tungsten-loaded tip Yes
Teleflex Turnpike Gold Catheter Hybrid multilayer: dual bidirectional coils with inner braid and external nylon spiral coil 2.9 2.9 2.1 135 0.0165 0.014 Yes, gold-plated tip Yes
Teleflex Turnpike Catheter Hybrid multilayer: dual bidirectional coils with inner braid 2.9 2.6 1.6 135, 150 0.0165 0.014 Yes, tungsten-loaded tip Yes
Teleflex SuperCross Microcatheter OTW - 0.014 Straight and Flexible Tip Braided 2.5 – 1.8 130, 150 0.017 0.014 Yes, single markerband Yes
Teleflex SuperCross Microcatheter OTW - 0.014 Angled Tips: 45°, 90°, 120°, and 90° Extended Tip Dual coil design; platinum/tungsten coil tip 3.2 – 2.4 130, 150 0.017 0.014 Yes, platinum/tungsten coil tip Yes

Catheters / Specialty Catheters

View Chart
Company Name Product Name Catheter Size (F) Working Length (cm) Minimum Guiding Catheter ID (inch) Comments
Teleflex GuideLiner Navigation Catheter – 163 5.5 F (model 5570), 6 F (model 5571), 7 F (model 5572), 8 F (model 5573) Helps to protect the arterial wall during deep-seating of the GuideLiner; its construction combines the advantages of atraumatic vessel navigation with support for GuideLiner advancement in tortuous anatomy
Teleflex GuideLiner V3 Catheter 5, 5.5, 6, 7, 8 150 ≥ 0.056 (5 F), ≥ 0.066, ≥ 0.070 (6 F), ≥ 0.078 (7 F), ≥ 0.088 (8 F) Features a half-pipe design for seamless collar transition; this rapid-exchange, coaxial mother-and-child guide extension is delivered through standard guide catheters, resulting in an ID approximately one F size smaller than the guide catheter; used to access discrete regions of the coronary and/or peripheral vasculature and to facilitate placement of interventional devices
Teleflex SuperCross Microcatheter OTW - 0.014 Angled Tips: 45°, 90°, 120°, and 90° Extended Tip Distal: 2.4; proximal: 3.2 130, 150 0.014 Low-profile, hydrophilic-coated, OTW microcatheter is available in multiple tip angle options (45°, 90°, 120°, and 90° extended tip) with a dual coil design for good torque response and delivery into branched anatomy
Teleflex SuperCross Microcatheter OTW - 0.014 Straight and Flexible Tip Distal: 1.8; proximal: 2.5 130, 150 0.014 Low-profile, hydrophilic-coated, braided OTW microcatheter with straight tip and flexible tip options provides support when navigating tortuous anatomy and bifurcated vessels

Sheaths / Reinforced Sheaths

View Chart
Company Name Product Name Size (F) Length (cm) Guidewire Compatibility (inch) Curved or Straight Radiopaque Tip Hydrophilic Coating
Teleflex Fortress 4, 5, 6, 7, 8 45, 65, 90, 100 0.035 Curved, straight Radiopaque markerband 5–8 hydrophobic
Teleflex Super Arrow-Flex Introducer Sets (Adult) 5–11 11–100 0.035 Straight Yes Yes
Teleflex Super Arrow-Flex Sheath Introducer Sets (Pediatric) 5–6 7.5 0.021 Straight Yes Yes

Sheaths / Special Access Sheaths

View Chart
Company Name Product Name Size (F) Length (cm) Guidewire Compatibility (inch) Curved or Straight Radiopaque Tip Type of Special Access
Teleflex Arrow Radial Access Sheaths 4, 5, 6 7, 11, 24 0.018 Straight Yes Radial
Teleflex Super Arrow-Flex Carotid Access Sheath Introducer Set 7 90 – Straight Yes Carotid
Teleflex Super Arrow-Flex Renal Access Sheath Introducer Sets 6, 7 45 0.035–0.038 Curved, 90° Yes Renal

Sheaths / Standard Sheaths

View Chart
Company Name Product Name Size (F) Length (cm) Guidewire Compatibility (inch) Curved or Straight Radiopaque Tip
Teleflex Arrow Percutaneous Sheath Introducer Kits (Pediatric) 4–6 5, 7.5 0.021 Straight Yes
Teleflex Arrow Percutaneous Sheath Introducer Kits (Adult) 4–9 11 0.035 Straight Yes

Stents / Balloon-Expandable Stents

View Chart
Company Name Product Name Material Used Maximum Guidewire Size (inch) Introducer Size (F) Stent Diameter (mm) Stent Length (mm) Delivery System Length (cm) CE Mark Indications
Teleflex Dynamic Stainless steel 0.035 6 (5–9 diameter), 7 (10 diameter) 5, 6, 7, 8, 9, 10 15, 25, 38, 56 80, 130 Iliac arteries
Teleflex Dynamic Renal Cobalt chromium 0.014 4 (4.5–5 diameter), 5 (6–7 diameter) 4.5, 5, 6, 7 12, 15, 19 140 Renal arteries
Teleflex Dynetic-35 Cobalt chromium 0.035 6 (for all sizes) 5–10 18, 28, 38, 58, 78 90, 130, 170 Iliac arteries
Teleflex Pro-Kinetic Energy Explorer Cobalt chromium 0.014 4 2, 2.5, 3, 3.5, 4, 4.5, 5 9, 15, 20, 30, 40 140 Infrapopliteal arteries

Stents / Self-Expanding Stents

View Chart
Company Name Product Name Material Used Introducer Size (F) Guidewire Compatibility (inch) Stent Diameter (mm) Stent Length (mm) Delivery System Length (cm) CE Mark Indications
Teleflex Astron Nitinol 6 0.035 7, 8, 9, 10 30, 40, 60, 80 70, 120 Iliac artery
Teleflex Astron Pulsar Nitinol 4 0.018 4, 5, 6, 7 20, 30, 40, 60, 80 70–75, 120–135 Femoral and infrapopliteal arteries
Teleflex Pulsar-18 Nitinol 4 0.018 4, 5, 6, 7 20, 30, 40, 60, 80, 100, 120, 150, 170, 200 90, 135 Femoral and infrapopliteal arteries
Teleflex Pulsar-18 T3 Nitinol 4 0.018 4, 5, 6, 7 20, 30, 40, 60, 80, 100, 120, 150, 170, 200 90, 135 Superficial femoral proximal popliteal and infrapopliteal arteries
Teleflex Pulsar-35 Nitinol 6 0.035 5, 6, 7 30, 40, 60, 80, 100, 120, 150, 170, 200 90, 135 Femoral and proximal popliteal arteries

Wires / Mandril/Specialty Guidewires

View Chart
Company Name Product Name Type Diameter (inch) Length (cm) Tip Type Coating Type
Teleflex Cruiser-18 Stainless steel 0.018 195, 300 Coil Hydrophilic tip, hydrophobic shaft

Other Devices / Closure Devices

View Chart
Company Name Product Name Type Puncture Size (F) Maximum Wire Compatibility (inch) Comments
Teleflex Manta Vascular Closure Device Bioresorbable implant Following the use of 10–20 F device or sheaths (12–25 F OD) 0.035 Designed specifically for closure of large bore femoral artery access sites; easy positioning without the need for preclosure; simple deployment with help from auditory and visual cues and a reliable closure using a single device; the 14-F device is indicated for closure of femoral arterial access sites after the use of 10- to 14-F devices or sheaths (maximum OD/profile of 18 F), and the 18-F device is indicated for closure of femoral arterial access sites after the use of 15- to 18-F devices or sheaths (maximum OD/profile of 25 F)

Other Devices / Dialysis Catheters

View Chart
Company Name Product Name Size (F) Tip-to-Cuff Insertion Length (cm) Tip Type Number of Lumens Sideholes (Yes/No) Coated (Yes/No) Acute or Chronic
Teleflex Arrow NextStep Hemodialysis Catheterization Sets (Antegrade Catheters) 15 19, 23, 27, 31, 42, 50 Step tip Two Yes No Chronic
Teleflex Arrow-Clark VectorFlow Hemodialysis Catheterization Sets (Antegrade and Retrograde) 15 19, 23, 27, 31, 42, 55 Symmetric tip Two Yes No Chronic
Teleflex Arrow NextStep Hemodialysis Catheterization Sets (Retrograde Catheters) 15 19, 23, 27, 31 Step tip Two Yes No Chronic
Teleflex Arrow Pediatric Hemodialysis Catheterization Kits 8, 9 11, 13 Staggered tip Two Yes No Acute
Teleflex Arrow Precurved Arrowgard Blue Hemodialysis Catheterization Kits 14 15, 20 Staggered tip Two Yes Yes, Arrowgard Blue antimicrobial protection Acute
Teleflex Arrow Three Lumen Pressure Injectable Hemodialysis Catheterization Kits 12 15, 20, 25 Staggered tip Three Yes No Acute
Teleflex Arrow You-Bend Arrowgard Blue Hemodialysis Catheterization Kits 12 13, 16, 20 Staggered tip Two Yes Yes, Arrowgard Blue antimicrobial coating Acute
Teleflex Arrow Hemodialysis Catheterization Kits 12 16, 20, 25 Staggered tip Two Yes No Acute
Teleflex Arrow Edge Hemodialysis Catheterization Sets (Antegrade Catheters) 15 19, 23, 27, 31, 50 V-tip Two Yes No Chronic
Teleflex Arrow Cannon II Plus Hemodialysis Catheterization Sets (Retrograde Catheters) 15 19, 23, 27, 31, 50 V-tip Two Yes No Chronic
Teleflex Arrow Arrowgard Blue Hemodialysis Catheterization Kits 12 15, 20 Staggered tip Two Yes Yes, Arrowgard Blue antimicrobial protection Acute
Teleflex Arrow Arrowgard Blue Hemodialysis Catheterization Kits 14 15, 20, 25 Staggered tip Two Yes No Acute

Other Devices / Thrombus Aspiration Devices

View Chart
Company Name Product Name Type Maximum Tip Diameter (mm) Minimum Guide Catheter Size (F) Catheter Length (cm)
Teleflex Pronto V4 Extraction Catheter Embedded longitudinal wire; hydrophilic coating; patented Silva tip; maximized extraction lumen and force; 5.5, 6, 7, 8 F 1.64–2.2 6, 7, 8 138
Teleflex Pronto LP Extraction Catheter Low-profile; hydrophilic coating; patented Silva tip; round, braided shaft; delivery stylet 1.35 6 140
Teleflex Pronto V3 Extraction Catheter Full-length braided shaft; hydrophilic coating; patented Silva tip; maximized extraction lumen and force 1.65 6 140
Teleflex Pronto LP 5 F Extraction Catheter Low-profile; hydrophilic coating; patented Silva tip; delivery stylet; 5-F guide catheter compatibility 1.35 5 138
Teleflex Pronto .035 Extraction Catheter Large-vessel thrombus aspiration catheter; full-length braided shaft; patented Silva tip 3.25 10 (sheath) 115

Catheters / Multifunctional Catheters

View Chart
Company Name Product Name Sheath Compatibility (F) Recommended Guidewire Size (inch) Balloon Diameters (mm) Balloon Lengths (cm) Working Length (cm) Support Catheter Construction Dilator Construction Balloon Nominal Pressure (atm) Balloon Rated Burst Pressure (atm) Comments
Teleflex Oscar Peripheral Multifunctional Catheter 4 0.014 2, 2.5, 3, 3.5 Variable from 2-18 127 Reinforced shaft, polymer braid with straight tip and platinum-iridium marker Straight with olive-shaped stainless steel tip 8 14 (ø 3.5 mm), 16 (ø 2, 2.5, 3 mm) Multicomponent system (support catheter, dilator, and PTA balloon) indicated for percutaneous transluminal interventions in the peripheral vasculature to provide support during access into and to dilate stenoses in femoral, popliteal and infrapopliteal arteries; also intended for injection of radiopaque contrast media for the purpose of angiography
Teleflex Oscar Peripheral Multifunctional Catheter 6 0.018 4, 5, 6, 7 Variable from 2-18, 2-10 (ø 7 mm) 72 (ø 7 mm), 80, 128 Reinforced shaft, polymer braid with straight tip and platinum-iridium marker Straight with olive-shaped stainless steel tip 6 12 (ø 7 mm), 14 (ø 4, 5, 6 mm) Multicomponent system (support catheter, dilator, and PTA balloon) indicated for percutaneous transluminal interventions in the peripheral vasculature to provide support during access into and to dilate stenoses in femoral, popliteal, and infrapopliteal arteries; also intended for injection of radiopaque contrast media for the purpose of angiography

More Categories:

Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View All

Advertisement

Latest News


April 17, 2026

Bayer’s Asundexian FXIa Inhibitor Demonstrates Reduction in Ischemic Stroke in OCEANIC-STROKE Study

April 16, 2026

Rapid Medical’s Tigertriever 25 Cleared by FDA to Treat LVO Stroke

April 15, 2026

Stereotaxis to Acquire Robocath

Most Read Articles


A Private Practice Physician’s Experience Treating Chronic Venous Insufficiency

By Robert A. Edwards, DO

Update on Modern Complex Abdominal Aortic Repair Options

With Jason T. Lee, MD; Steven Maximus, MD, FACS; Gustavo Oderich, MD, FACS; Benjamin W. Starnes, MD, FACS; Carlos Timaran, MD; Kak Khee Yeung, MD, PhD, FEBVS; and Javairiah Fatima, MD, FACS, DFSVS

Transforming the Future of PE Care: Expanding Mechanical Thrombectomy Through Innovation

By Mehdi Shishehbor, DO, MPH, PhD

Back to Top
Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous
Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

News• Current Issue• Archive• Device Guide• Advertising• About Calendar• Contact• Privacy• Submissions• Subscriptions


Endovascular Today (ISSN 1551-1944 print and ISSN 2689-792X online) is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field.



magazine Created with Sketch.

Free Print Subscriptions

Fill 1 Created with Sketch.

Email Newsletter



twitter-icon LinkedIn Created with Sketch. instagram BlueSky-Circle
Cardiac Interventions Today
Group 7 Copy 3 Created with Sketch.
bmc-secondary-mark-color copy Created with Sketch.

© 2026 Bryn Mawr Communications II, LLC.  
All Rights Reserved   •   Privacy Policy

one-trust-button