31 Technology Drive, Irvine, CA 92618

PHONE: (800) 225-2500

down-arrow Created with Sketch.
down-arrow Created with Sketch.

Balloons / Specialty Balloons

View Chart
Company Name Product Name Nominal Pressure (atm) Rated Burst Pressure (atm) Guidewire Compatibility (inch) Size (F) Sheath Compatibility (F) Shaft Length (cm) Balloon Diameters (mm) Balloon Lengths (cm)
Cerenovus Ascent Occlusion Balloon Catheter – – 0.017 2.9 5 150 4, 6 7, 9, 10, 15 (mm)

Advertisement

Advertisement

Catheters / Guiding Catheters

View Chart
Company Name Product Name Type Size (F) Length (cm) Internal Diameter (inch) Radiopaque Tip (Yes/No) Hydrophilic Coated
Cerenovus Envoy DA (Distal Access) Guiding Catheter Stainless steel braid 6 95, 105 0.071 Yes, three tip shapes available Yes
Cerenovus Envoy DA XB (Distal Access, Extra-Backup Support) Guiding Catheter Stainless steel braid 6 95, 105 0.071 Yes, three tip shapes available Yes
Cerenovus Envoy Guiding Catheter Stainless steel braid 5 90, 100 0.056 Yes, five tip shapes available Yes
Cerenovus Envoy Guiding Catheter Stainless steel braid 6 90, 100 0.070 Yes, six tip shapes available Yes
Cerenovus Envoy Guiding Catheter Stainless steel braid 7 90, 100 0.078 Yes, six tip shapes available Yes
Cerenovus Envoy XB (Extra-Backup Support) Guiding Catheter Stainless steel braid 6 90, 100 0.070 Yes, six tip shapes available Yes

Catheters / Specialty Catheters

View Chart
Company Name Product Name Catheter Size (F) Working Length (cm) Minimum Guiding Catheter ID (inch) Comments
Cerenovus Cerenovus Large Bore Catheter (0.071-inch ID) OD: 0.081 inch (distal), 0.0825-inch (proximal) 115, 125, 132 – –

Embolization / Cerebral Coils

View Chart
Company Name Product Name Materials Used Coil Type Method of Detachment US FDA Indicated Use Comments
Cerenovus Cerepak Detachable Coil System Platinum Complex, random complex, and helical Mechanical The Cerepak Uniform, Uniform XL, Uniform 3D, Heliform Soft, Heliform XtraSoft, Heliform XL, Heliform XtraSoft XL, Freeform, Freeform Mini Detachable Coil Systems are indicated for embolization of intracranial aneurysms, neurovascular abnormalities such as arteriovenous malformations and arteriovenous fistulae, and arterial and venous embolizations in the peripheral vasculature; the Cerepak Freeform XtraSoft Detachable Coil System is indicated for embolization of intracranial aneurysms Cerepak has a comprehensive portfolio of coils with a variety of shapes, primary winds from 0.015 to 0.009 inches, and lengths from 60 to 1 cm
Cerenovus Trufill DCS Orbit Detachable Coil System Bare platinum Complex fill, complex standard, mini complex fill, helical fill, tight distal loop technology Hydraulic detachment Intracranial aneurysms, AVMs, and AVFs; embolization of peripheral vasculature Excellent conformability and concentric filling for greater packing density
Cerenovus Orbit Galaxy Detachable Coil System Bare platinum, polypropylene stretch-resistant suture Complex framing, filling, and finishing coils Hydraulic detachment Indicated for embolizing intracranial aneurysms; indicated for embolizing intracranial aneurysms, AVMs, and AV fistulas; embolization of peripheral vasculature Coil has a unique ability to seek out and fill the open spaces in an aneurysm, enabling greater packing density

Embolization / Liquid Embolics

View Chart
Company Name Product Name Materials Used US FDA Indicated Use Comments
Cerenovus Trufill n-BCA Liquid Embolic System Trufill n-BCA, Trufill ethiodized oil, and tantalum powder; these components must be used as a system Embolization of cerebral AVMs when presurgical devascularization is desired; premarket approval device A clear, free-flowing liquid, which polymerizes quickly on contact with body fluid or tissue; it offers convenient preparation and delivery, customized radiopacity for visualization, and effective penetration of AVMs

Stents / Cerebral Stents

View Chart
Company Name Product Name Materials Used Stent Diameters (mm) Stent Lengths (mm) Recommended Guidewire Size (inch) Recommended Guide Catheter Size (inch)
Cerenovus Codman Enterprise 2 Vascular Reconstruction Device Nitinol, laser-cut, closed-cell design with platinum markers 5 (for vessels 2.5–4) 16, 23, 30, 39 No guidewire 5- or 6-F guiding catheter for a 0.021 delivery microcatheter
Cerenovus Codman Enterprise Vascular Reconstruction Device Nitinol 4.5 (for vessels 2.5–4) 14, 22, 28, 37 No guidewire 5- or 6-F guiding catheter for a 0.021 delivery microcatheter

Wires / Hydrophilic Guidewires

View Chart
Company Name Product Name Type Diameter (inch) Length (cm) Tip Type Comments
Cerenovus Agility 10 Steerable Guidewire Stainless steel with hydrophilic coating 0.010 195 Shapeable tip The soft tips enable easy shapeability and safe vessel access; available in standard and soft configurations
Cerenovus Agility 14 Steerable Guidewire Stainless steel with hydrophilic coating 0.014 205, 350 Shapeable tip The soft tips enable easy shapeability and safe vessel access; available in standard and soft configurations
Cerenovus Agility 16 Steerable Guidewire Stainless steel with hydrophilic coating 0.016 175, 205 Shapeable tip The soft tips enable easy shapeability and safe vessel access; available in standard and soft configurations
Cerenovus Neuroscout 14 Steerable Guidewire Stainless steel with hydrophilic coating 0.014 205, 300 Shapeable tip Specifically designed for excellent tip shaping and shape retention

Other Devices / Mechanical Thrombectomy (Neurovascular)

View Chart
Company Name Product Name Sheath Compatibility (F) Guidewire Compatibility (inch) Working Length (cm) Mode of Operation US FDA Indicated Use
Cerenovus Embotrap III Revascularization Device - 22 mm (indication 1.5-5mm) – – 194 (overall length) – Designed for use in the anterior and posterior neurovasculature in vessels such as the internal carotid artery, the M1 or M2 segments of the middle cerebral artery, and basilar arteries (vessel sizes ranging from 1.5 mm up to 5 mm for the 5-mm diameter device)
Cerenovus Embotrap III Revascularization Device - 37 mm (indication 1.5-5 mm) – – 195 (overall length) – Designed for use in the anterior and posterior neurovasculature in vessels such as the internal carotid artery, the M1 or M2 segments of the middle cerebral artery, and basilar arteries (vessel sizes ranging from 1.5 mm up to 5 mm for the 5-mm diameter device)
Cerenovus Embotrap III Revascularization Device - 45 mm (indication 1.5-6.5mm) – – 196 (overall length) – Designed for use in the anterior and posterior neurovasculature in vessels such as the internal carotid artery, the M1 or M2 segments of the middle cerebral artery, and basilar arteries (vessel sizes ranging from 1.5 mm up to 6.5 mm for the 6.5-mm diameter device)

Catheters / Microcatheters

View Chart
Company Name Product Name Type of Catheter Construction Proximal Size (F) Middle Size (F) Distal Size (F) Catheter Working Length (cm) Catheter Endhole Diameter ID (inch) Recommended Guidewire Size (inch) Radiopaque Tip (Yes/No) Hydrophilic Coating (Yes/No)
Cerenovus Transit Microcatheters Braid/coil design 2.8 – 2.5 135, 150 0.021 0.018 (maximum) Yes Yes
Cerenovus Rapidtransit Microcatheters Braid/coil design 2.3 – 2.3 75, 155, 175 (proximal, middle, and distal lengths); 100, 135 (proximal lengths) 0.021 0.018 (maximum) Yes Yes
Cerenovus Prowler Select Plus Braid/coil design 2.3 – 2.3 150 0.021 0.018 (maximum) Yes Yes
Cerenovus Prowler Select LP-ES Braid/coil design 2.8 – 1.9 150 0.0165 0.014 (maximum) Yes Yes
Cerenovus Prowler Plus Braid/coil design 2.8 – 2.3 110, 135, 150 0.021 0.018 (maximum) Yes Yes
Cerenovus Prowler 27 Braid/coil design 3 – 2.6 150 0.027 0.018 (maximum) Yes Yes
Cerenovus Prowler 14 Braid/coil design 2.8 – 1.9 150, 170 0.0165 0.014 (maximum) Yes Yes
Cerenovus Prowler 10 Braid/coil design 2.3 – 1.7 150 0.015 0.012 (maximum) Yes Yes

More Categories:

Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View All

Advertisement

Latest News


May 4, 2026

ENGULF Analysis Shows Reduced Blood Loss With E2’s Hēlo System in PE Procedures

May 1, 2026

FDA Awards IDE for Pivotal Study of enVVeno’s Venous Valve to Treat Severe Deep CVI

April 29, 2026

Cydar Maps Planning and Navigation Solution Expanded to Enable Use in Complex Branched and Visceral Cases

Most Read Articles


Update on Modern Complex Abdominal Aortic Repair Options

With Jason T. Lee, MD; Steven Maximus, MD, FACS; Gustavo Oderich, MD, FACS; Benjamin W. Starnes, MD, FACS; Carlos Timaran, MD; Kak Khee Yeung, MD, PhD, FEBVS; and Javairiah Fatima, MD, FACS, DFSVS

A Private Practice Physician’s Experience Treating Chronic Venous Insufficiency

By Robert A. Edwards, DO

Addressing Pelvic Venous Disease With a New Class of Coils

With Gloria Salazar, MD, FSIR; Ronald Winokur, MD, FSIR, RPVI; Marissa Famularo, DO; Eric Hager, MD; Driss Raissi, MD, MBA, FSIR; and Brian Do, DO

Back to Top
Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous
Centers

Carotid Coding Dialysis Embolization EVAR HTN Limb Salvage Neurointervention Oncology Radial Regulatory Renal SFA TEVAR Venous

News• Current Issue• Archive• Device Guide• Advertising• About Calendar• Contact• Privacy• Submissions• Subscriptions


Endovascular Today (ISSN 1551-1944 print and ISSN 2689-792X online) is a publication dedicated to bringing you comprehensive coverage of all the latest technology, techniques, and developments in the endovascular field.



magazine Created with Sketch.

Free Print Subscriptions

Fill 1 Created with Sketch.

Email Newsletter



twitter-icon LinkedIn Created with Sketch. instagram BlueSky-Circle
Cardiac Interventions Today
Group 7 Copy 3 Created with Sketch.
bmc-secondary-mark-color copy Created with Sketch.

© 2026 Bryn Mawr Communications II, LLC.  
All Rights Reserved   •   Privacy Policy

one-trust-button