View Chart| Company Name | Product Name | Nominal Pressure (atm) | Rated Burst Pressure (atm) | Guidewire Compatibility (inch) | Shaft Length (cm) | Sheath Compatibility (F) | Balloon Diameters (mm) | Balloon Lengths (cm) |
|---|---|---|---|---|---|---|---|---|
| Contego Medical LLC | Paladin Carotid PTA Balloon (2-in-1: balloon + filter) | 8 | 14 (5.0 mm balloon); 11 (5.5 mm balloon) | 0.014 | Catheter length: 140 | 6 | 5, 5.5 | 2, 3 |
Advertisement
Advertisement
Stents / Carotid Artery Stenting Systems
View Chart| Company Name | Product Name | Tapered Stent Diameters (Proximal/Distal) (mm) | Tapered Stent Lengths (mm) | Straight Stent Diameters (mm) | Straight Stent Lengths (mm) | Embolic Protection Device | Type | Position | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|---|---|
| Contego Medical LLC | Neuroguard IEP System 3-in-1: stent + balloon + filter | 9/7/8, 8/6/7 (hourglass shape) | 30, 40 | – | – | Integrated embolic protection (IEP) filter | Integrated embolic protection (IEP) filter | DIstal | Indicated for improving the carotid luminal diameter in subjects at high risk for adverse events from carotid endarterectomy who require carotid revascularization and meet the following criteria: patients with symptomatic stenosis of the common or internal carotid artery with ≥ 50% as determined by angiography using NASCET methodology, or patients with asymptomatic stenosis of the common or internal carotid artery with ≥ 80% as determined by angiography using NASCET methodology; and patients with reference vessel diameters 4–8 mm; also indicated for postdilation of the stent component with simultaneous capture and removal of embolic material; the Neuroguard IEP System should always be used in conjunction with an available primary distal embolic protection device as described in the IFU |
Other Devices / Embolic Protection Devices
View Chart| Company Name | Product Name | Type | Position | US FDA Indicated Use |
|---|---|---|---|---|
| Contego Medical LLC | Neuroguard IEP System 3-in-1: stent + balloon + filter | Integrated embolic protection (IEP) filter | Distal | Indicated for improving the carotid luminal diameter in subjects at high risk for adverse events from carotid endarterectomy who require carotid revascularization and meet the following criteria: patients with symptomatic stenosis of the common or internal carotid artery with ≥ 50% as determined by angiography using NASCET methodology, or patients with asymptomatic stenosis of the common or internal carotid artery with ≥ 80% as determined by angiography using NASCET methodology; and patients with reference vessel diameters 4–8 mm; also indicated for postdilation of the stent component with simultaneous capture and removal of embolic material; the Neuroguard IEP System should always be used in conjunction with an available primary distal embolic protection device as described in the IFU |
| Contego Medical LLC | Paladin Carotid PTA Balloon (2-in-1: balloon + filter) | Integrated embolic protection (IEP) filter | Distal | Indicated for percutaneous transluminal angioplasty (PTA) in the carotid arteries with capture and removal of embolic material; also indicated for postdilation of self-expanding stents in the carotid arteries with capture and removal of embolic material; the diameter of the arterial site for filter deployment should be no more than 7 mm; the Paladin Carotid PTA Balloon System with Integrated Embolic Protection (IEP) should always be used in conjunction with an available embolic protection device when used for postdilation of self-expanding stents |
Other Devices / Mechanical Thrombectomy/Thrombolysis (Peripheral/Venous)
View Chart| Company Name | Product Name | Sheath Compatibility (F) | Guidewire Compatibility (inch) | Working Length (cm) | Mode of Operation | US FDA Indicated Use |
|---|---|---|---|---|---|---|
| Contego Medical LLC | Excipio LV (Large Vessel) | 12.6 | 0.035 | 125 | The Excipio LV Thrombectomy Device is a rapid exchange catheter with an integrated nitinol braided basket designed to mechanically displace thrombus | Indicated for the nonsurgical removal of emboli and thrombi from peripheral blood vessels |
| Contego Medical LLC | Excipio SV (Small Vessel) | 7 | 0.014 | 165 | The Excipio SV Thrombectomy Device is a sterile, single-use catheter consisting of a catheter with an integrated nitinol braided basket designed to mechanically displace thrombus | Indicated for the nonsurgical removal of soft emboli and thrombi from peripheral blood vessels |
More Categories: