Advertisement
Advertisement
BD Interventional
1625 W. 3rd St., Tempe, AZ 85281
PHONE: (480) 894-9515 | FAX: (480) 966-7062
Balloons / Drug-Coated Balloons (SFA/Popliteal Indication)
View Chart| Company Name | Product Name | Drug Type | Drug Concentration (µg/mm2) | Excipient Type | Guidewire Compatibility (inch) | Shaft Length (cm) | Sheath Compatibility (F) | Balloon Diameters (mm) | Balloon Lengths (mm) | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|---|---|---|
| BD Interventional | Lutonix 035 (SFA/popliteal indication) | Paclitaxel | 2 | Polysorbate, sorbitol | 0.035 | 130 | 5 | 4–7 | 40, 60, 80, 100, 120, 150, 220 | Indicated for PTA, after appropriate vessel preparation, of de novo, restenotic, or in-stent restenotic lesions up to 300 mm in length in native superficial femoral or popliteal arteries with reference vessel diameters of 4 to 7 mm |
| BD Interventional | Lutonix 018 | Paclitaxel | 2 | Polysorbate, sorbitol | 0.018 | 100, 130 | 4, 5 | 4–7 | 40, 60, 80, 100, 150, 220, 300 | Indicated for PTA, after appropriate vessel preparation, of de novo, restenotic, or in-stent restenotic lesions up to 300 mm in length in native superficial femoral or popliteal arteries with reference vessel diameters of 4 to 7 mm; also indicated for PTA, after predilatation, for treatment of stenotic lesions of dysfunctional native arteriovenous dialysis fistulae 4 to 7 mm in diameter and up to 80 mm in length |
Advertisement
Advertisement
Balloons / PTA Balloons
View Chart| Company Name | Product Name | Nominal Pressure (atm) | Rated Burst Pressure (atm) | Guidewire Compatibility (inch) | Shaft Length (cm) | Sheath Compatibility (F) | Balloon Diameters (mm) | Balloon Lengths (cm) |
|---|---|---|---|---|---|---|---|---|
| BD Interventional | Ultraverse 018 | 6 | Up to 16 | 0.018 | 75, 130, 150, 200 | 4–6 | 2, 2.5, 3, 3.5, 4, 5, 6, 7, 8, 9 | 2, 4, 6, 8, 10, 12, 15, 20, 22, 30 |
| BD Interventional | Ultraverse RX | 6 | Up to 16 | 0.014 | 150, 200 | 4–5 | 1.25, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6, 7 | 1.5, 2, 4, 6, 8, 10, 12, 15, 20, 25, 30 |
| BD Interventional | Ultraverse 035 | 6, 8 | Up to 21 | 0.035 | 75, 130 | 5–7 | 3, 4, 5, 6, 7, 8, 9, 10, 12 | 2, 4, 6, 8, 10, 12, 15, 20, 25, 30 |
| BD Interventional | Ultraverse 014 | 6 | Up to 16 | 0.014 | 150 | 4–5 | 1.5, 2, 2.5, 3, 3.5, 4, 5 | 2, 4, 6, 8, 10, 12, 15, 22, 30 |
| BD Interventional | Highlander 014 | 6 | 30 | 0.014 | 150 | 4 | 2–4 | 2–15 |
| BD Interventional | Dorado | 8 | Up to 24 | 0.035 | 40, 80, 120, 135 | 5–7 | 3, 4, 5, 6, 7, 8, 9, 10 | 2, 4, 6, 8, 10, 12, 15, 17, 20 |
| BD Interventional | Conquest 40 | 8 | Up to 40 | 0.035 | 50, 75 | 6–8 | 4, 5, 6, 7, 8, 9, 10, 12 | 2, 3, 4, 6, 8, 10 |
| BD Interventional | Conquest | 8 | Up to 30 | 0.035 | 50, 75, 120 | 6–8 | 5, 6, 7, 8, 9, 10, 12 | 2, 3, 4, 6, 8 |
| BD Interventional | Atlas Gold | 4, 6 | Up to 18 | 0.035 | 80, 120 | 7–12 | 12, 14, 16, 18, 20, 22, 24, 26 | 2, 4, 6 |
| BD Interventional | Atlas | 4, 6 | Up to 18 | 0.035 | 75, 120 | 7–12 | 12, 14, 16, 18, 20, 22, 24, 26 | 2, 4, 6 |
Balloons / Specialty Balloons
View Chart| Company Name | Product Name | Nominal Pressure (atm) | Rated Burst Pressure (atm) | Guidewire Compatibility (inch) | Size (F) | Sheath Compatibility (F) | Shaft Length (cm) | Balloon Diameters (mm) | Balloon Lengths (cm) |
|---|---|---|---|---|---|---|---|---|---|
| BD Interventional | True Dilatation Balloon Valvuloplasty Catheter | 3 | 6 | 0.035 | – | 11–14 | 110 | 18–28 | 4.5 |
| BD Interventional | True Flow Valvuloplasty Perfusion Catheter | 3 | 6 | 0.035 | – | 11–16 | 110 | 18–26 | 3.5 |
| BD Interventional | UltraScore | 6–8 | Up to 14 | 0.014 (2–7 mm), 0.035 (4–8 mm) | – | 4–6 | 130, 150 | 2, 2.5, 3, 3.5, 4, 5, 6, 7, 8 | 2, 4, 8, 10, 12, 15, 20, 30 |
| BD Interventional | Vida BAV Balloon Valvuloplasty Catheter | 4–6 | 6–8 | 0.035 | – | 8–12 | 100 | 18–26 | 4 |
| BD Interventional | Vida PTV Balloon Dilatation Catheter | 4–6 | 12–18 | 0.035 | – | 7–12 | 100 | 12–26 | 2–6 |
Catheters / Guiding Catheters
View Chart| Company Name | Product Name | Type | Size (F) | Length (cm) | Internal Diameter (inch) | Radiopaque Tip (Yes/No) | Hydrophilic Coated |
|---|---|---|---|---|---|---|---|
| BD Interventional | Usher | Tapered, stainless steel braid, PTFE | 6 | 83, 130 | 0.027 | Yes | Yes |
| BD Interventional | Sidekick (tapered) | Tapered, stainless steel braid, PTFE | 7 | 70, 110 | 0.046 | Yes | Yes |
| BD Interventional | Sidekick (nontapered) | Nontapered, stainless steel braid, PTFE | 7 | 70, 110 | 0.067 | Yes | Yes |
Catheters / Specialty Catheters
View Chart| Company Name | Product Name | Catheter Size (F) | Working Length (cm) | Minimum Guiding Catheter ID (inch) | Comments |
|---|---|---|---|---|---|
| BD Interventional | Seeker Crossing Support Catheter | 4, 5 | 65, 90, 135, 150 | 4, 5 F | Hydrophilic-coated support catheter with a 30-cm radiopaque marking system, sized to support standard 0.014-, 0.018-, and 0.035-inch guidewires |
Embolization / Vascular Plugs
View Chart| Company Name | Product Name | Material | Target Vessel Diameter (mm) | Delivery Wire Length (cm) | Recommended Catheter Sizes: ID (inch) or OD (F) | US FDA Indicated Use |
|---|---|---|---|---|---|---|
| BD Interventional | Caterpillar Arterial Embolization Device | Nitinol fiber segments with a polyethylene and polyurethane occlusion membrane | 3–6 | 155 | 0.038 | Indicated for arterial embolization in the peripheral vasculature; contraindicated for use in vessels subject to cyclic bending, such as locomotive joints or muscle beds |
| BD Interventional | Caterpillar Arterial Embolization Device | Nitinol fiber segments with a polyethylene and polyurethane occlusion membrane | 5–7 | 155 | 0.056 | Indicated for arterial embolization in the peripheral vasculature; contraindicated for use in vessels subject to cyclic bending, such as locomotive joints or muscle beds |
| BD Interventional | Caterpillar Micro Arterial Embolization Device | Nitinol fiber segments with a polyethylene and polyurethane occlusion membrane | 1.5–4 | 170 | Microcatheter: 0.027 | Indicated for arterial embolization in the peripheral vasculature; contraindicated for use in vessels subject to cyclic bending, such as locomotive joints or muscle beds |
Sheaths / Reinforced Sheaths
View Chart| Company Name | Product Name | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Curved or Straight | Radiopaque Tip | Hydrophilic Coating |
|---|---|---|---|---|---|---|---|
| BD Interventional | Halo One Thin-Walled Guiding Sheath | 4–6 | 10, 25, 45, 70, 90 | 0.018, 0.035 | Straight | Yes | Yes |
Sheaths / Special Access Sheaths
View Chart| Company Name | Product Name | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Curved or Straight | Radiopaque Tip | Type of Special Access |
|---|---|---|---|---|---|---|---|
| BD Interventional | Arteriovenous Sheath Tunneler Set | 5, 6 | 19, 22, 23 | Guidewire not included | Curved, Straight | No | Intended to aid in creating subcutaneous tunnels for placement of AV grafts up to 7 mm |
| BD Interventional | Peripheral Vascular Sheath Tunneler Set | 8.5, 11 | 48, 60 | Guidewire not included | Straight | No | Intended to aid in creating subcutaneous tunnels for placement of AV grafts up to 7 mm |
Stents / Balloon-Expandable Covered Stents
View Chart| Company Name | Product Name | Material Used | Maximum Guidewire Size (inch) | Introducer Size (F) | Stent Diameter (mm) | Stent Length (mm) | Delivery System Length (cm) | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|---|
| BD Interventional | LifeStream Balloon Expandable Vascular Covered Stent | 316L stainless steel and ePTFE | 0.035 | 6, 7, 8 | 5, 6, 7, 8, 9, 10, 12 | 16, 26, 37/38, 58 | 80, 135 | Indicated for the treatment of atherosclerotic lesions in common and external iliac arteries |
Stents / Balloon-Expandable Stents
View Chart| Company Name | Product Name | Material Used | Maximum Guidewire Size (inch) | Introducer Size (F) | Stent Diameter (mm) | Stent Length (mm) | Delivery System Length (cm) | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|---|
| BD Interventional | Valeo Balloon Expandable Biliary Stent | 316L stainless steel | 0.035 | 6, 7 | 6, 7, 8, 9, 10 | 17,* 18,† 26, 36, 56‡ (*only available in 9–10-mm diameters; †only available in 6–8-mm diameters; ‡only available in 7–8-mm diameters) | 80, 120 | Biliary |
Stents / Self-Expanding Stents
View Chart| Company Name | Product Name | Material Used | Introducer Size (F) | Guidewire Compatibility (inch) | Stent Diameter (mm) | Stent Length (mm) | Delivery System Length (cm) | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|---|
| BD Interventional | E-Luminexx Biliary Stent | Nitinol | 6 | 0.035 | 4, 5, 6, 7, 8, 9, 10, 12, 14 | 20, 30, 40, 60, 80, 100, 120 | 80, 135 | Biliary |
| BD Interventional | E-Luminexx Vascular Stent | Nitinol | 6 | 0.035 | 7, 8, 9, 10 | 20, 30, 40, 60, 80, 100 | 80, 135 | Iliac |
| BD Interventional | LifeStar Biliary Stent System | Nitinol | 6 | 0.035 | 6, 7, 8, 9, 10, 12, 14 | 20, 30, 40, 60, 80, 100, 120 | 80, 135 | Biliary |
| BD Interventional | LifeStar Vascular Stent System | Nitinol | 6 | 0.035 | 7, 8, 9, 10 | 20, 30, 40, 60, 80, 100 | 80, 135 | Iliac |
| BD Interventional | LifeStent 5F Vascular Stent System | Nitinol | 5 | 0.014–0.035 | 5, 6, 7 | 20, 30, 40, 60, 80, 100, 120, 150*, 170† (*only available in 5–6 mm diameters, †only available in 5 mm diameter) | 80, 135 | SFA, full popliteal |
| BD Interventional | LifeStent and LifeStent XL Biliary Stent System | Nitinol | 6 | 0.035 | 5, 6, 7, 8, 9, 10 | 20, 30, 40, 60, 80, 100,* 120,* 150† (*only available in 5–7 mm diameters; †only available in 6, 7 mm diameters) | 80, 130 | Biliary |
| BD Interventional | LifeStent and LifeStent XL Vascular Stent System | Nitinol | 6 | 0.035 | 5, 6, 7 | 20, 30, 40, 60, 80, 100, 120, 150, 170 | 80, 130 | SFA, full popliteal |
| BD Interventional | LifeStent Solo Vascular Stent System | Nitinol | 6 | 0.035 | 6, 7 | 200 | 100, 135 | SFA, full popliteal |
Stents / Self-Expanding Stent Grafts
View Chart| Company Name | Product Name | Materials Used | Introducer Size (F) | Guidewire Compatibility (inch) | Stent Diameter (mm) | Stent Length (mm) | Delivery System Length (cm) | US FDA Indicated Use | Comments |
|---|---|---|---|---|---|---|---|---|---|
| BD Interventional | Covera Vascular Covered Stent | Nitinol/ePTFE | 8, 9 | 0.035 | 6, 7, 8, 9, 10 | 30, 40, 60, 80, 100 | 80, 120 | Indicated for use in hemodialysis patients for the treatment of stenoses in the venous outflow of an AV fistula and at the venous anastomosis of ePTFE or other synthetic AV grafts | – |
| BD Interventional | Fluency Plus Endovascular Stent Graft | Nitinol/ePTFE | 8, 9, 10 | 0.035 | 6, 7, 8, 9, 10, 12, 13.5 | 40, 60, 80, 100, 120 | 80, 117 | Indicated for use in the treatment of in-stent restenosis in the venous outflow of hemodialysis patients dialyzing by either an AVF or AV graft and for the treatment of stenosis in the venous outflow of hemodialysis patients dialyzing by an AV graft | – |
Stents / Venous Stents
View Chart| Company Name | Product Name | Stent Material | Cell Design | Introducer Size (F) | Guidewire Compatibility (inch) | Stent Diameter (mm) | Stent Length (mm) | Delivery System | Delivery System Length (cm) |
|---|---|---|---|---|---|---|---|---|---|
| BD Interventional | Venovo Venous Stent System | Nitinol | Open-cell | 8–10 | 0.035 | 10, 12, 14, 16, 18, 20 | 40, 60, 80, 100, 120, 140, 160 | Triaxial, thumbwheel | 80, 120 |
Wires / Hydrophilic Guidewires
View Chart| Company Name | Product Name | Type | Diameter (inch) | Length (cm) | Tip Type | Comments |
|---|---|---|---|---|---|---|
| BD Interventional | Porter | Stainless steel | 0.014 | 195, 300 | Straight, 3-, 6-, 9-, 12-gauge tip stiffness | Hydrophilic guidewire in various levels of tip stiffness, providing excellent trackability, steerability, visibility, and support for delivery of therapeutic devices |
Wires / Mandril/Specialty Guidewires
View Chart| Company Name | Product Name | Type | Diameter (inch) | Length (cm) | Tip Type | Coating Type | Comments |
|---|---|---|---|---|---|---|---|
| BD Interventional | Guidewire | Nitinol + lubricious PTFE coating, hydrophilic tip | 0.018 | 220, 270, 320 | 50° angled | PTFE | For use with Rotarex S |
Other Devices / Atherectomy Devices
View Chart| Company Name | Product Name | Minimum Vessel Diameter (mm) | Sheath Compatibility (F) | Crossing Profile (inch) | Working Length (cm) | Tip Length (cm) |
|---|---|---|---|---|---|---|
| BD Interventional | Crosser 14S | 1.1 | 5 | 0.044 (1.1 mm) | 106, 146 | – |
| BD Interventional | Crosser S6 | 0.6 | 5 | 0.025 (0.6 mm) | 106, 154 | – |
| BD Interventional | Rotarex Rotational Excisional Atherectomy System | 3 | 6 | 0.079 | 110, 135 | – |
| BD Interventional | Rotarex Rotational Excisional Atherectomy System | 5 | 8 | 0.104 | 85, 110 | – |
Other Devices / CTO Crossing Devices
View Chart| Company Name | Product Name | Catheter Size (F) | Wire Size (inch) | Working Length (cm) | Minimum Guiding Catheter ID (inch) | Comments |
|---|---|---|---|---|---|---|
| BD Interventional | Crosser 14S | 5 | 0.014 | 106, 146 | 0.067 | Recanalizes CTOs through ultrasonic mechanical vibration and cavitation; includes the GeoAlign Marketing System; compatible with Sidekick Support Catheter; available in OTW and RX configurations |
| BD Interventional | Crosser S6 | 5 | – | 106, 154 | 0.055 | Recanalizes CTOs through ultrasonic mechanical vibration and cavitation; includes the GeoAlign Marking System; compatible with Usher Support Catheter |
Other Devices / Dialysis Catheters
View Chart| Company Name | Product Name | Size (F) | Tip-to-Cuff Insertion Length (cm) | Tip Type | Number of Lumens | Sideholes (Yes/No) | Coated (Yes/No) | Acute or Chronic |
|---|---|---|---|---|---|---|---|---|
| BD Interventional | Reliance XK | 16 | 19, 23, 27, 31, 35, 42, 50 (straight), 19, 24, 28, 31 (alphacurve) | Step tip | Dual | Yes | No | Chronic |
| BD Interventional | Pristine | 15.5 | 19, 23, 28, 33, 55 | Symmetric | Dual | No | No | Chronic |
| BD Interventional | HemoStar XK | 16 | 19, 23, 27, 31, 35, 42 (straight), 19, 24, 28, 31 (alphacurve) | Stepped | Dual | Yes | No and yes, silver sulfadiazine | Chronic |
| BD Interventional | HemoStar | 14.5 | 15, 19, 23, 27, 31, 35, 42 (straight), 19, 24, 28, 31 (alphacurve) | Stepped | Dual | Yes | No and yes, silver sulfadiazine | Chronic |
| BD Interventional | HemoSplit XK | 16 | Straight: 19, 23, 27, 31, 35, 42; alphacurve: 19, 24, 28, 31 | Split tip | Dual | Yes | No and yes, silver sulfadiazine | Chronic |
| BD Interventional | HemoSplit | 14.5 | 15, 19, 23, 27, 31, 35, 42 (straight), 19, 24, 28, 31 (alphacurve) | Split tip | Dual | Yes | No and yes, silver sulfadiazine | Chronic |
| BD Interventional | GlidePath Retro | 14.5 | 15, 19, 23, 27, 31, 35, 42, 50 | Symmetric | Dual | Yes | No | Chronic |
| BD Interventional | GlidePath 10F | 10 | 10, 12, 15, 19, 23 | Symmetric | Dual | Yes | No | Chronic |
| BD Interventional | GlidePath | 14.5 | 15, 19, 23, 27, 31, 35, 42, 50 (straight), 19, 24, 28, 31 (alphacurve) | Symmetric | Dual | Yes | No | Chronic |
| BD Interventional | Equistream XK | 16 | 19, 23, 27, 31, 35, 42 (straight), 19, 24, 28 (alphacurve) | Split tip | Dual | Yes | No | Chronic |
| BD Interventional | Equistream | 14.5 | 15, 19, 23, 27, 31, 35, 42 (straight), 19, 24, 28, 31 (alphacurve) | Split tip | Dual | Yes | No | Chronic |
| BD Interventional | Decathlon DF | 16 | 19, 23, 27, 31, 35, 50 (straight) | Split tip | Dual | Yes | No | Chronic |
| BD Interventional | GlidePath 7.5F | 7.5 | 15, 19, 23, 27, 31, 35 | Symmetric | Dual | Yes | No | Chronic |
Other Devices / Endovenous Ablation
View Chart| Company Name | Product Name | Technology | Wavelength (nm) | Sheath Sizes (F) | Sheath Lengths (cm) | US FDA Indicated Use |
|---|---|---|---|---|---|---|
| BD Interventional | Venclose Maven Perforator Catheter | Radiofrequency | Heating length (0.5 cm) | 6 (with working length of 40 cm) | – | Intended for endovascular coagulation of blood vessels in patients with perforator and tributary vein reflux |
| BD Interventional | Venclose RF Ablation Catheter | Radiofrequency | Adjustable heating length (2.5 cm/10 cm) | 6 (with working lengths of 60 cm and 100 cm) | 7, 12 | Intended for endovascular coagulation of blood vessels in patients with superficial vein reflux |
| BD Interventional | Venclose RF Generator | Radiofrequency | – | – | – | Intended for endovascular coagulation of blood vessels in patients with superficial vein reflux |
Other Devices / Hybrid Vascular Grafts
View Chart| Company Name | Product Name | Materials Used | Nitinol Reinforced Section Diameter (mm) | Nitinol Reinforced Section Length (cm) | Vascular Graft Section Diameter (mm) | Vascular Graft Section Length (cm) | Introducer Size (F) | Recommended Guidewire (inch) | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|---|---|
| BD Interventional | Venaflo II | Vascular ePTFE grafts for hemodialysis | – | – | 6–7, straight; 4–6, 4–7, stepped | 10–50 | – | – | Straight, stepped, CenterFlex, and stepped CenterFlex configurations are indicated for use as subcutaneous arteriovenous conduits for blood access only |
| BD Interventional | Impra Vascular Grafts | ePTFE with carbon impregnated into the inner portions of the graft wall | – | – | 3–19, straight; 6–19, flex; 6–4, 7–4, 8–5, tapered; 4–6, 4–7, 5–8, stepped | 5–90 | – | – | For use as vascular prostheses; straight, tapered, short tapered, stepped, and CenterFlex graft configurations are intended for use as subcutaneous arteriovenous conduits for blood access, bypass, or reconstruction of peripheral arterial blood vessels |
| BD Interventional | Impra Carboflo | ePTFE with carbon impregnated into the inner portions of the graft wall | – | – | 4–8, straight; 6–10 flex; 6–4, 7–4, tapered; 4–6, 4–7, 5–8 stepped | 10–80 | – | – | Indicated for use as vascular prostheses |
| BD Interventional | Distaflo | ePTFE with carbon impregnated into the inner portions of the graft wall; graft is also modified with a proprietary cuff at the distal end | – | – | 6–8, standard; 6, small-cuff; 6, mini-cuff | 50–90 | – | – | Intended for bypass or reconstruction of peripheral arterial blood vessels |
Other Devices / Inflation Devices
View Chart| Company Name | Product Name | Color | Pressure Range (atm) | Barrel Volume (mL) | Luminescent Gauge (Yes/No) | Gauge | Latch Type | Threads |
|---|---|---|---|---|---|---|---|---|
| BD Interventional | Presto | Blue/white | 0–40 | 30 | No | Angled | – | – |
Other Devices / Mechanical Thrombectomy/Thrombolysis (Peripheral/Venous)
View Chart| Company Name | Product Name | Sheath Compatibility (F) | Guidewire Compatibility (inch) | Working Length (cm) | Mode of Operation | US FDA Indicated Use |
|---|---|---|---|---|---|---|
| BD Interventional | Aspirex Mechanical Aspiration Thrombectomy System | 6, 8, 10 | 0.018, 0.025 | 85, 110, 135 | Aspiration | Indicated for the removal of acute emboli and thrombi from vessels of the peripheral venous system |
Other Devices / Percutaneous Arteriovenous Fistula Creation
View Chart| Company Name | Product Name | Size (F) | Maximum Guidewire Compatibility (inch) | Catheter Working Length (cm) | Recommended Introducer Size (F) | Fistula Site(s) | Outflow | Access | Mechanism of Action | AV Connection | Energy Source | Imaging Guidance | Adjunctive Procedures |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BD Interventional | WavelinQ EndoAVF System | 4 | 0.014 | 43 (venous catheter); 50 (arterial catheter) | 5 | (1) Concomitant ulnar artery and ulnar vein; or (2) concomitant radial artery and radial vein | Split-flow fistula (cephalic or basilic vein) | Venous and arterial | Radiofrequency ablation | Platelet deposition and endothelium development of fistula tract | Electrosurgical unit (BD ESU-1) | Fluoroscopy and ultrasound | Recommended embolization of a brachial vein at index procedure |
Other Devices / Snares
View Chart| Company Name | Product Name | Catheter Size/Length (F/cm) | Working Diameters (mm) | Snare Length (cm) | Snare Type | Comments |
|---|---|---|---|---|---|---|
| BD Interventional | Bard Snare Retrieval Kit | 9/63, 11/58 | 20 | 120 | A 20-mm radiopaque nitinol snare loop with a 6-F ID snare catheter assembly, a 9-F ID retrieval sheath with dilator assembly, and an 11-F ID access sheath | – |
Other Devices / Vena Cava Filters
View Chart| Company Name | Product Name | Indicated Caval Diameter (mm) (based on average caval diameter) | Maximum Deployed Length (mm) | Catheter Carrier System ID (F) | Material | Design | Approach | Permanent/Retrievable |
|---|---|---|---|---|---|---|---|---|
| BD Interventional | Denali Filter | 28 | 50 (unconstrained) | 8.4 | Nitinol | Bilevel, conical | Femoral/jugular | Optional (permanent or retrievable) |
Balloons / Drug-Coated Balloons (AV Indication)
View Chart| Company Name | Product Name | Drug Type | Drug Concentration (µg/mm2) | Excipient Type | Guidewire Compatibility (inch) | Shaft Length (cm) | Sheath Compatibility (F) | Balloon Diameters (mm) | Balloon Lengths (mm) | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|---|---|---|
| BD Interventional | Lutonix 035 (AV Indication) | Paclitaxel | 2 | Polysorbate, sorbitol | 0.035 | 75, 100 | 5–7 | 4–12 | 40, 60, 80, 100 | Indicated for PTA, after predilatation, for treatment of stenotic lesions of dysfunctional native arteriovenous dialysis fistulas that are 4 to 12 mm in diameter and up to 80 mm in length |
Other Devices / Powered Bone Lesion Biopsy Systems
View Chart| Company Name | Product Name | Introducer Needle Size (g) | Introducer Needle Length (cm) | Biopsy Needle Size (g) | Biopsy Needle Length (cm) |
|---|---|---|---|---|---|
| BD Interventional | BD Trek Powered Bone Biopsy System | 10 | 10 | 12 | 14.8 |
| BD Interventional | BD Trek Powered Bone Biopsy System | 10 | 15 | 12 | 19.8 |
| BD Interventional | BD Trek Powered Bone Biopsy System | 10 | 6 | 12 | 10.8 |
| BD Interventional | BD Trek Powered Bone Biopsy System | 11 | 6 | 13 | 10.8 |
| BD Interventional | BD Trek Powered Bone Biopsy System | 11 | 10 | 13 | 14.8 |
| BD Interventional | BD Trek Powered Bone Biopsy System | 11 | 15 | 13 | 19.8 |
Other Devices / Powered Bone Marrow Biopsy Systems
View Chart| Company Name | Product Name | Biopsy Needle Size (g) | Biopsy Needle Length (cm) |
|---|---|---|---|
| BD Interventional | BD Trek Powered Bone Biopsy System | 11 | 10 |
| BD Interventional | BD Trek Powered Bone Biopsy System | 11 | 15 |
More Categories:
Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View AllAdvertisement