Advertisement
Advertisement
Boston Scientific Corporation
One Boston Scientific Place, Natick, MA 01760
PHONE: (508) 650-8000
Aortic (AAA) / Guidewires
View Chart| Company Name | Product Name | Diameter (inch) | Length (cm) | Flexible Tip Length (cm) |
|---|---|---|---|---|
| Boston Scientific Corporation | Amplatz Super Stiff Guidewire | 0.035, 0.038 | 145, 180, 260 | 6 |
| Boston Scientific Corporation | Amplatz Super Stiff J Guidewire | 0.035 | 145, 180, 260 | 7 |
| Boston Scientific Corporation | Amplatz Super Stiff J Guidewire | 0.038 | 145, 180 | 7 |
| Boston Scientific Corporation | Amplatz Super Stiff ST Guidewire | 0.035, 0.038 | 145 | 4 |
| Boston Scientific Corporation | Amplatz Super Stiff ST Guidewire | 0.035, 0.038 | 260 | 1 |
| Boston Scientific Corporation | Meier C Curve | 0.035 | 260, 300 | 10 |
| Boston Scientific Corporation | Meier J Curve | 0.035 | 185 | 15 |
Advertisement
Advertisement
Aortic (AAA) / Noncompliant Balloons
View Chart| Company Name | Product Name | Size (F) | Balloon Length (cm) | Guidewire Compatibility (inch) | Catheter Length (cm) | Maximum Inflated Balloon Diameter (mm) |
|---|---|---|---|---|---|---|
| Boston Scientific Corporation | XXL Balloon Catheter | 7 (for 12–14 mm diameters), N/A (for 16–18 mm diameters) | 2, 3, 6 | 0.035 | 75, 120 | 12, 14, 16, 18 |
Aortic (TAA) / Guidewires
View Chart| Company Name | Product Name | Diameter (inch) | Length (cm) | Flexible Tip Length (cm) | Primary Curve Radius (mm) | Secondary Curve Radius (mm) |
|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Amplatz Super Stiff Guidewire | 0.035, 0.038 | 145, 180, 260 | 6 | – | – |
| Boston Scientific Corporation | Amplatz Super Stiff J Guidewire | 0.038 | 145, 180 | 7 | – | – |
| Boston Scientific Corporation | Amplatz Super Stiff J Guidewire | 0.035 | 145, 180, 260 | 7 | – | – |
| Boston Scientific Corporation | Amplatz Super Stiff ST Guidewire | 0.035, 0.038 | 260 | 1 | – | – |
| Boston Scientific Corporation | Amplatz Super Stiff ST Guidewire | 0.035, 0.038 | 145 | 4 | – | – |
| Boston Scientific Corporation | Meier C Curve | 0.035 | 260, 300 | 10 | – | – |
| Boston Scientific Corporation | Meier J Curve | 0.035 | 185 | 15 | – | – |
Balloons / Drug-Coated Balloons (SFA/Popliteal Indication)
View Chart| Company Name | Product Name | Drug Type | Drug Concentration (µg/mm2) | Excipient Type | Guidewire Compatibility (inch) | Shaft Length (cm) | Sheath Compatibility (F) | Balloon Diameters (mm) | Balloon Lengths (mm) | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Ranger Drug-Coated Balloon | Paclitaxel | 2 | Citrate ester | 0.018 | 80, 90, 135, 150 | 5 (4–6 mm); 6 (7 mm) | 4, 5, 6, 7 | 40, 60, 80, 100, 120, 150, 200 | Indicated for percutaneous transluminal angioplasty (PTA) of de novo or restenotic lesions up to 180 mm in length located in native superficial femoral and proximal popliteal arteries (SFA/PPA) with reference vessel diameters of 4 to 7 mm |
Balloons / PTA Balloons
View Chart| Company Name | Product Name | Nominal Pressure (atm) | Rated Burst Pressure (atm) | Guidewire Compatibility (inch) | Shaft Length (cm) | Sheath Compatibility (F) | Balloon Diameters (mm) | Balloon Lengths (cm) |
|---|---|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Athletis Ultra-High-Pressure Balloon Catheter | 8 | Up to 40 | 0.035 | 50, 75, 135 | 6 (4–8 mm), 7 (9–10 mm), 8 (12 mm) | 4–10, 12 | 2, 3, 4, 6, 8, 10 |
| Boston Scientific Corporation | Charger Balloon Catheter | 8 (9–10 mm), 10 (3–8, 12 mm) | Up to 20 | 0.035 | 75, 135 | 5 (3–7 X 80 mm), 6 (8–10 mm, 6 X 180 mm, 6 X 200 mm, 7 X 100–200 mm), 7 (12 mm) | 3–10, 12 | 2, 3, 4, 6, 8, 10, 12, 15, 18, 20 |
| Boston Scientific Corporation | Coyote Balloon Catheter (Monorail) | 8 | 14 | 0.014 | 90, 150 | 4 | 1.5, 2, 2.5, 3, 3.5, 4 | 4 (1.5 mm only), 6, 8, 10, 12, 15, 22 |
| Boston Scientific Corporation | Coyote Balloon Catheter (OTW) | 8 | 14 | 0.014 | 90, 150 | 4 | 1.5, 2, 2.5, 3, 3.5, 4 | 4 (1.5 mm only), 6, 8, 10, 12, 15, 22 |
| Boston Scientific Corporation | Coyote ES Monorail PTA Balloon Dilatation Catheter | 6 | 12 (3.5–4 mm), 14 (1.5–3 mm) | 0.014 | 142–146 | 4 | 1.5, 2, 2.5, 3, 3.5, 4 | 2, 3, 4 |
| Boston Scientific Corporation | Coyote ES Over-the-Wire PTA Balloon Dilatation Catheter | 6 | 12 (3.5–4 mm), 14 (1.5–3 mm) | 0.014 | 142–146 | 4 | 1.5, 2, 2.5, 3, 3.5, 4 | 2, 3, 4 |
| Boston Scientific Corporation | Mustang Balloon Catheter | 8 (9–10 mm), 10 (3–8, 12 mm) | Up to 24 | 0.035 | 40, 75, 135 | 5 (3–7 mm), 6 (8–10 mm), 7 (12 mm) | 3–10, 12 | 2, 3, 4, 6, 8, 10, 12, 15, 18, 20 |
| Boston Scientific Corporation | Peripheral Cutting Balloon | 6 | 10 | 0.018 | 50, 90, 135 | 6 (5, 6 mm), 7 (7, 8 mm) | 5, 6, 7, 8 | 2 |
| Boston Scientific Corporation | Sterling Monorail PTA Balloon Dilatation Catheter | 6 | 12 (8 mm), 14 (3–7 mm) | 0.018 | 80, 135, 150 | 4 (up to 8 X 4), 5 (7 X 6, 8 X 6) | 2, 2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6, 6.5, 7, 8 | 1, 1.5, 2, 3, 4, 6, 22 |
| Boston Scientific Corporation | Sterling Over-the-Wire PTA Balloon Dilatation Catheter | 6 | 10 (9–10 mm), 12 (8 mm), 14 (4–7 mm) | 0.018 | 40, 80, 90, 135, 150 | 4 (up to 8 X 4), 5 (7 X 6, 8 X 6) | 2, 2.5, 3, 3.5, 4, 5, 6, 7, 8, 9, 10 | 2, 3, 4, 6, 8, 10, 12, 15, 20, 22 |
| Boston Scientific Corporation | Sterling SL Monorail PTA Balloon Dilatation Catheter | 6 | 14 | 0.018 | 90, 150 | 4 | 2, 2.5, 3, 3.5, 4 | 8, 10, 12, 15 |
| Boston Scientific Corporation | Sterling SL Over-the-Wire PTA Balloon Dilatation Catheter | 6 | 14 | 0.018 | 90, 150 | 4 | 2, 2.5, 3, 3.5, 4 | 8, 10, 12, 15 (4-mm diameter on 90-cm shaft; not available in 8- or 10-cm balloon lengths) |
| Boston Scientific Corporation | XXL Balloon Catheter | 5 (16–18 mm), 8 (13–14 mm) | 5 (16, 18 mm), 8 (13–14 mm) | 0.035 | 75, 120 | 7 (12, 14 mm), N/A (16, 18 mm) | 12, 14, 16, 18 | 2, 4, 6 |
| Boston Scientific Corporation | Enroute Enflate Transcarotid RX Balloon Dilatation Catheter | 8 | 14 | 0.014 | 75 | 4 (5 for 6 mm diameter) | 4, 4.5, 5, 5.5, 6 | 2.5, 3.5 |
Catheters / Angiographic Catheters: Selective, Nonhydrophilic Coated
View Chart| Company Name | Product Name | Type | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Radiopaque Tip | Variety of Selective Shapes |
|---|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Imager II Angiographic Catheter | Braided | 5 | 40, 65, 100 | 0.035, 0.038 | Yes | Wide variety of cerebral, visceral, and multipurpose shapes available |
Catheters / Drainage Catheters
View Chart| Company Name | Product Name | Type | Tip | Size (F) | Length (cm) | Durometer | Radiopaque Tip (Yes/No) |
|---|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Flexima All-Purpose Drainage Catheter | All purpose | J tip, locking loop, tight locking loop | 6, 7, 8, 10, 12, 14 | 20, 25 | Firm, regular | No |
| Boston Scientific Corporation | Flexima Biliary Drainage Catheter | Biliary | Locking loop | 8, 10, 12, 14 | 35 | Regular, firm | Optional RO marker |
| Boston Scientific Corporation | Flexima Urinary Drainage Catheter | Ureteral stent | Double pigtail | 6, 8, 10 | 20, 22, 24, 26, 28 | Regular | No |
| Boston Scientific Corporation | Flexima Urinary Drainage Catheter | Nephrostomy | Locking loop | 8, 10, 12, 14 | 25 | Regular, firm | No |
| Boston Scientific Corporation | Flexima VanSonnenberg Drainage Catheter | Dual-lumen sump | J tip, locking loop | 12, 14 | 30, 35 | Regular | No |
| Boston Scientific Corporation | Percuflex All-Purpose Drainage Catheter | All purpose | Locking loop | 8, 10, 12, 14 | 20, 25 | – | No |
| Boston Scientific Corporation | Percuflex Urinary Drainage Catheter | Ureteral stent | Double pigtail | 6, 8, 10 | 20, 22, 24, 26, 28 | – | No |
| Boston Scientific Corporation | Percuflex Urinary Drainage Catheter | Nephroureteral stent | Double pigtail | 8, 10 | 22, 24, 26, 28 | – | No |
| Boston Scientific Corporation | Percuflex Urinary Drainage Catheter | Nephrostomy | Locking loop, amplatz anchor, malecot, stenting malecot | 8, 10, 12, 14, 20, 24 | 25, 30, 35 | – | No |
Catheters / Guiding Catheters
View Chart| Company Name | Product Name | Type | Size (F) | Length (cm) | Internal Diameter (inch) | Radiopaque Tip (Yes/No) | Hydrophilic Coated |
|---|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Mach1 Peripheral Guide Catheter | Braided | 8 | 55, 90 | 0.091 | Yes | No |
| Boston Scientific Corporation | Mach1 Peripheral Guide Catheter | Braided | 7 | 55, 90 | 0.081 | Yes | No |
| Boston Scientific Corporation | Mach1 Peripheral Guide Catheter | Braided | 6 | 55, 90 | 0.070 | Yes | No |
Catheters / Specialty Catheters
View Chart| Company Name | Product Name | Catheter Size (F) | Working Length (cm) | Minimum Guiding Catheter ID (inch) | Comments |
|---|---|---|---|---|---|
| Boston Scientific Corporation | Rubicon Support Catheter | 4 (0.014, 0.018 inch), 5 (0.035 inch); distal tip profile: 0.014 (0.018-inch distal tip profile), 0.018 (0.022-inch distal tip profile), 0.035 (0.037-inch distal tip profile) | 65, 90, 135, 150 | 0.014, 0.018, 0.035 | Intended to facilitate placement and support of guidewires and other interventional devices within the peripheral vasculature and to allow for exchange of guidewires and provide a conduit for the delivery of saline or contrast solutions |
| Boston Scientific Corporation | Rubicon Control Support Catheter | Rubicon 0.014, 0.018 (4 F); Rubicon 0.035 (5 F); distal tip profile: Rubicon Control 0.014 (40° distal tip); Rubicon Control 0.018 (40°, straight distal tip): Rubicon Control 0.035 (45°, 20°, straight distal tip) | 65, 90, 135, 150 | 0.014, 0.018, 0.035 | Intended to facilitate placement and support of guidewires and other interventional devices within the peripheral vasculature for complex anatomy |
Embolization / Embolization Coils
View Chart| Company Name | Product Name | Type (Detachable, Pushable) | Material | Coil Diameter (mm) | Coil Length (cm) | Recommended Delivery Catheter Sizes (ID) (inch) | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Complex Helical-18 Fibered Platinum Coils | Pushable | Platinum tungsten alloy | 4, 6, 7, 8, 10, 11 | 2, 3, 4, 5, 6, 7 | 0.021 | 0.018-inch fibered platinum coils are intended for arterial and venous embolizations in the peripheral vasculature |
| Boston Scientific Corporation | Embold Fibered Detachable Coil System | Detachable | Platinum tungsten alloy | 2, 3, 4, 5, 6, 8, 10, 12, 14, 18, 20, 22, 32 | 4, 6, 8, 12, 10, 15, 20, 30, 50, 60 | 0.021–0.027 | Indicated to obstruct or reduce rate of blood flow in the peripheral vasculature |
| Boston Scientific Corporation | Embold Packing Detachable Coil System | Detachable | Platinum tungsten alloy | – | 15, 30, 45, 60 | 0.021–0.027 | Indicated to obstruct or reduce rate of blood flow in the peripheral vasculature |
| Boston Scientific Corporation | Embold Soft Detachable Coil System | Detachable | Platinum tungsten alloy | 2, 3, 4, 5, 6, 8 | 2, 4, 6, 8, 10, 12, 15, 20, 30, 60 | 0.021–0.027 | Indicated to obstruct or reduce rate of blood flow in the peripheral vasculature |
| Boston Scientific Corporation | Figure 8-18 Fibered Platinum Coils | Pushable | Platinum tungsten alloy | 2 | 1 | 0.021 | 0.018-inch fibered platinum coils are intended for arterial and venous embolizations in the peripheral vasculature |
| Boston Scientific Corporation | IDC Soft Interlocking Detachable Coil | Detachable | Platinum tungsten alloy | 2, 3, 4, 5 | 2, 4, 6, 8, 10, 12 | 0.021 | Indicated to obstruct or reduce blood flow in the peripheral vasculature; the device is not intended for neurovascular use |
| Boston Scientific Corporation | Interlock-18 Fibered IDC Occlusion System | Detachable | Platinum tungsten alloy | 2, 3, 4, 5, 6, 8, 10, 12, 14, 18, 20, 22 | 2.3, 4, 4.1, 5, 5.8, 6, 8, 10, 12, 15, 20, 30, 50, 60 | 0.021 | Indicated to obstruct or reduce blood flow in the peripheral vasculature; the device is not intended for neurovascular use |
| Boston Scientific Corporation | Interlock-35 Fibered IDC Occlusion System | Detachable | Platinum tungsten alloy | 3, 4, 6, 8, 10, 12, 15, 18, 20 | 4, 4.5, 6, 9, 10, 14, 20, 25, 30, 40 | 5-F Imager II selective diagnostic catheter (0.035 or 0.038 inch ID) | Indicated to obstruct or reduce blood flow in the peripheral vasculature; the device is not intended for neurovascular use |
| Boston Scientific Corporation | Multi-Loop-18 Fibered Platinum Coils | Pushable | Platinum tungsten alloy | 4 | 3 | 0.021 | 0.018-inch fibered platinum coils are intended for arterial and venous embolizations in the peripheral vasculature |
| Boston Scientific Corporation | Multi-Loop-35 Fibered Platinum Coils | Pushable | Platinum tungsten alloy | 3, 4, 5, 6, 7, 9 | 2, 3, 4, 5, 6 | 0.035 | For arterial and venous embolization in the peripheral vasculature |
| Boston Scientific Corporation | Straight-18 Fibered Platinum Coils | Pushable | Platinum tungsten alloy | Straight | 0.2, 0.5 | 0.021 | 0.018-inch fibered platinum coils are intended for arterial and venous embolizations in the peripheral vasculature |
| Boston Scientific Corporation | VortX Diamond-18 Fibered Platinum Coils | Pushable | Platinum tungsten alloy | 3, 4, 5, 6 | 2.3, 4.1, 5.8, 8 | 0.021 | 0.018-inch fibered platinum coils are intended for arterial and venous embolizations in the peripheral vasculature |
| Boston Scientific Corporation | VortX-18 Fibered Platinum Coils | Pushable | Platinum tungsten alloy | 3, 4, 5, 6 | 2.2, 4.2, 6, 8.5 | 0.021 | 0.018-inch fibered platinum coils are intended for arterial and venous embolizations in the peripheral vasculature |
| Boston Scientific Corporation | VortX-35 Fibered Platinum Coils | Pushable | Platinum tungsten alloy | 4, 5, 6, 7 | 3, 3.5, 5.3, 6.7 | 0.035 | For arterial and venous embolization in the peripheral vasculature |
Sheaths / Special Access Sheaths
View Chart| Company Name | Product Name | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Curved or Straight | Radiopaque Tip | Type of Special Access |
|---|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Accustick II Introducer System | 6 | 20 | 0.038 | Straight or J | Yes | For the introduction of 0.038-inch guidewires in nonvascular procedures; includes a coaxial 6-F sheath with RO marker and 4-F dilator, one 21-gauge needle 15 cm, and options to have 0.038-inch wire in straight or J tip with or without an 0.018-inch wire in the kit; can also be purchased without wires and needle accessories can be purchased separately |
| Boston Scientific Corporation | Enhance Transcarotid Peripheral Access Kit | 4 | 10, 15 | 0.018 | Flexible | No | Transcarotid access |
Sheaths / Standard Sheaths
View Chart| Company Name | Product Name | Size (F) | Length (cm) | Guidewire Compatibility (inch) | Curved or Straight | Radiopaque Tip |
|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Catapult Guide Sheath | 4, 5, 6, 7, 8 | 15, 45, 60, 90 | 0.035 | Straight and curved | With |
Stents / Balloon-Expandable Stents
View Chart| Company Name | Product Name | Material Used | Maximum Guidewire Size (inch) | Introducer Size (F) | Stent Diameter (mm) | Stent Length (mm) | Delivery System Length (cm) | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Express LD Iliac/Biliary Premounted Stent System | 316L stainless steel | 0.035 | 6 (up to 8 X 37 mm), 7 (up to 10 X 57 mm) | 6–10 (5 mm, biliary indication only) | 17, 25, 27, 37, 57 | 75, 135 | Iliac, biliary |
| Boston Scientific Corporation | Express SD Renal Monorail Premounted Stent System | 316L stainless steel | 0.018 | 5 (up to 6 X 18 mm), 6 (up to 7 X 19 mm) | 4, 5, 6, 7 | 14, 15, 18, 19 | 90, 150 | Renal, biliary |
Stents / Carotid Artery Stenting Systems
View Chart| Company Name | Product Name | Tapered Stent Diameters (Proximal/Distal) (mm) | Tapered Stent Lengths (mm) | Straight Stent Diameters (mm) | Straight Stent Lengths (mm) | Embolic Protection Device | Type | Position | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Carotid Wallstent Endoprosthesis | – | – | 6, 8, 10 (unconstrained) | 21, 22, 24, 29, 31, 36, 37 (unconstrained) | FilterWire EZ Embolic Protection System | Filter | Distal | Used in conjunction with the Boston Scientific EPS, is indicated for the treatment of patients at high risk for adverse events from carotid endarterectomy due to either anatomic or comorbid conditions who require carotid revascularization in the treatment of ipsilateral or bilateral carotid artery disease and meet the criteria outlined: patients with neurological symptoms and ≥ 50% stenosis of the common, internal carotid artery, and/or the bifurcation by ultrasound or angiography or patients without neurological symptoms and ≥ 80% stenosis of the common, internal carotid artery, and/or the bifurcation by ultrasound or angiogram, and patients with a reference vessel diameter within the range of 4–9 mm at the target lesion |
| Boston Scientific Corporation | Enroute Transcarotid Stent System | 8/6, 9/7, 10/8 | 30, 40 | 6, 7, 8, 9, 10 | 20 (6 mm only), 30, 40 | Enroute Transcarotid Neuroprotection System | Robust flow reversal | Proximal | Used in conjunction with the Enroute Transcarotid Neuroprotection System (NPS), is indicated for the treatment of patients at high risk and standard risk for adverse events from carotid endarterectomy, who require carotid revascularization and meet the criteria outlined below: High-risk patients with neurological symptoms and ≥ 50% stenosis of the common or internal carotid artery by ultrasound or angiogram or patients without neurological symptoms and ≥ 80% stenosis of the common or internal carotid artery by ultrasound or angiogram; standard risk patients with neurological symptoms and ≥ 70% stenosis of the common or internal carotid artery by ultrasound or ≥ 50% stenosis of the common or internal carotid artery by angiogram or patients without neurological symptoms and ≥ 70% stenosis of the common or internal carotid artery by ultrasound or ≥ 60% stenosis of the common or internal carotid artery by angiogram; all patients must have a vessel diameter of 4 to 9 mm at the target lesion, and carotid bifurcation must be located at minimum 5 cm above the clavicle to allow for placement of the Enroute Transcarotid NPS; please refer to instructions for use for indications, contraindications, warnings, and precautions |
Stents / Drug-Eluting Stents
View Chart| Company Name | Product Name | Drug Delivered | Material Used | Introducer Size (F) | Maximum Guidewire Size (inch) | Stent Diameter (mm) | Stent Length (mm) | Delivery System Length (cm) | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Eluvia Drug-Eluting Vascular Stent System | Paclitaxel | Nitinol | 6 | 0.035 | 6, 7 | 40, 60, 80, 100, 120, 150 | 130 | SFA/proximal popliteal |
Stents / Self-Expanding Stents
View Chart| Company Name | Product Name | Material Used | Introducer Size (F) | Guidewire Compatibility (inch) | Stent Diameter (mm) | Stent Length (mm) | Delivery System Length (cm) | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Epic Vascular Self-Expanding Stent System | Nitinol | 6 | 0.035 | 6, 7, 8, 9, 10, 12 | 20, 30, 40, 60, 80, 100, 120 | 75, 120 | Iliac |
| Boston Scientific Corporation | Innova Vascular Self-Expanding Stent System | Nitinol | 6 | 0.035 | 5, 6, 7, 8 | 20, 40, 60, 80, 100, 120, 150, 200 | 75, 130 | SFA/proximal popliteal |
| Boston Scientific Corporation | Venous Wallstent | Elgiloy | 7–9 | 0.035 | 10, 12, 14, 16, 18, 20 | 20, 40, 42, 55, 60, 68, 80, 90, 94 | 75 | Iliofemoral veins |
| Boston Scientific Corporation | WallFlex Biliary Transhepatic Stent System | Platinol wire braid, Permalume covering | 8, 8.5 | 0.035 | 8, 10 | 40, 60, 80, 100 | 75 | Biliary |
| Boston Scientific Corporation | Wallstent Endoprosthesis | Elgiloy | 6 | 0.035 | 6, 7, 8, 9, 10 | 18, 20, 23, 24, 34, 35, 36, 38, 39, 46, 47, 49, 52, 55, 59, 61, 66, 67, 69 | 75, 135 | Iliac |
| Boston Scientific Corporation | Wallstent Endoprosthesis | Elgiloy | 6–12 | 0.035 | 5, 6, 7, 8, 10, 12, 14, 16, 18, 20, 22, 24 | 20, 35, 40, 42, 45, 55, 60, 68, 70, 80, 90, 94 | 75, 135 (up to 12-mm diameter), 75 (14-mm diameter) | Tracheobronchial |
| Boston Scientific Corporation | Wallstent Endoprosthesis | Elgiloy | 6–9 | 0.035 | 8, 10, 12 | 20, 40, 42, 60, 68, 80, 90, 94 | 75 | Transhepatic biliary |
| Boston Scientific Corporation | Wallstent Endoprosthesis | Elgiloy | 7–9 | 0.035 | 10, 12 | 40, 42, 60, 68, 90, 94 | 75 | TIPS |
| Boston Scientific Corporation | Wallstent Endoprosthesis | Elgiloy | 6–10 | 0.035 | 10, 12, 14, 16 | 20, 40, 42, 60, 68, 90, 94 | 75 | Central venous |
Wires / Coiled Stainless Steel Guidewires
View Chart| Company Name | Product Name | Type | Diameter (inch) | Length (cm) | Tip Type | Antithrombogenic | Comments |
|---|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Amplatz Super Stiff Guidewire | Spring coil stainless steel | 0.035, 0.038 | 75, 145, 180, 260 | 3-mm J, straight, short taper | PTFE | Stiff, stainless steel core with flexible, highly radiopaque tip; intended to facilitate catheter placement and exchange during diagnostic or interventional procedures including AAA endovascular graft procedures |
| Boston Scientific Corporation | Meier | Spring coil stainless steel | 0.035, 0.038 | 185, 260, 300 | C, J | – | – |
| Boston Scientific Corporation | Peripheral RotaWire | Spring coil stainless steel core | 0.009/0.014 | 330 | Straight, extra support, or floppy taper | No | Designed for use with Peripheral RotaLink Plus |
| Boston Scientific Corporation | Platinum Plus Guidewire | Spring coil stainless steel core | 0.014, 0.018, 0.025 | 60, 145, 180, 260 | Straight; long and short taper | Available with Mediglide silicone coating or Glidex hydrophilic coating | Precoat technology produces an even coating of PTFE resulting in an ultra-smooth surface to facilitate independent coil movement |
| Boston Scientific Corporation | Starter Bentson | Fixed core | 0.035, 0.038 | 150, 180, 260 | Straight | With or without | 15-cm flexible tip |
| Boston Scientific Corporation | Starter J-Curve | Fixed core | 0.025, 0.035, 0.038 | 80, 125, 150, 180, 260 | J-tip | With or without | Available in 1.5-, 3-, 7.5-, 15-mm J-tip, finger straightenable |
| Boston Scientific Corporation | Starter J-Curve | Movable | 0.035, 0.038 | 125, 150, 260 | J-tip | With or without | Available in 3-, 15-mm J-tip, finger straightenable |
| Boston Scientific Corporation | Starter Newton | Fixed core | 0.035, 0.038 | 150 | Straight, J-tip | With or without | Available in straight 3-, 15-mm J-tip, finger straightenable |
| Boston Scientific Corporation | Starter Rosen | Fixed core | 0.035, 0.038 | 150, 180, 260 | J-tip | With or without | 1.5-mm J-tip |
| Boston Scientific Corporation | Starter Straight | Fixed core | 0.025, 0.035, 0.038 | 80, 150, 260 | Straight | With or without | Available in 1.5-, 3-, 7.5-, 15-mm J-tip, finger straightenable |
| Boston Scientific Corporation | Starter Straight | Movable | 0.035, 0.038 | 150 | Straight | No | Available in 3-, 15-mm J-tip, finger straightenable |
| Boston Scientific Corporation | Thruway | Spring coil stainless steel | 0.014, 0.018 | 130, 190, 300 | J-tip, straight, short, long, and extra long taper | Silicone | A larger inner core designed for added strength for access and stability during catheter placement and exchange, while a Teflon coating intended to facilitate entry allows smooth catheter tracking |
Wires / Hydrophilic Guidewires
View Chart| Company Name | Product Name | Type | Diameter (inch) | Length (cm) | Tip Type | Comments |
|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Fathom-14 Guidewire | Hybrid stainless steel and nitinol | 0.014 | 200, 300 | 10 cm with 2-cm shapeable or angled tip | Utilizes a unique slotted nitinol hypotube design to balance exceptional torquability with tip softness and proximal support |
| Boston Scientific Corporation | Fathom-16 Guidewire | Hybrid stainless steel and nitinol | 0.016 | 140, 180, 200, 215 | 10, 20 cm with 2-cm shapeable or angled tip | Utilizes a unique slotted nitinol hypotube design to balance exceptional torquability with tip softness and proximal support |
| Boston Scientific Corporation | Transend-14 Steerable Guidewire | Hydrophilic coating with scitanium core | 0.014 | 135, 165, 190 | 2-cm shapeable tip | Product features hydrophilic coating and good torque response |
| Boston Scientific Corporation | Transend-18 Steerable Guidewire | Hydrophilic coating with scitanium core | 0.018 | 135, 165 | 2-cm shapeable tip | Product features hydrophilic coating and good torque response |
| Boston Scientific Corporation | V-14 ControlWire Guidewire | Scitanium stainless steel core, polymer sleeve | 0.014 | 182, 300 | Straight, angled (shapeable) | Distal radiopaque section (distal 2 cm); single-piece core with torque jacket for 1:1 torque control; shapeable tip intended to facilitate accurate placement; proximal PTFE jacket intended to provide firm support and low friction surface |
| Boston Scientific Corporation | V-18 ControlWire Steerable Guidewire | Scitanium stainless steel core, polymer sleeve | 0.018 | 110, 150, 200, 300 | Straight (shapeable) | Hydrophilic performance and torque control designed for distal, peripheral access and contralateral approaches; single-piece core with torque jacket for 1:1 torque control; robust shapeable 3-cm tip intended to facilitate accurate placement; proximal PTFE jacket intended to provide firm support and low friction surface |
| Boston Scientific Corporation | Victory Guidewire | Stainless steel core, polymer sleeve | 0.014, 0.018 | 195, 300 | Straight (shapeable) | 12-g, 18-g, 25-g, and 30-g tip loads designed to cross highly resistant lesions; torque control designed for distal, peripheral access |
| Boston Scientific Corporation | Zipwire Hydrophilic Guidewire | Hydrophilic wire with nitinol core | 0.018, 0.025, 0.035, 0.038 | 80, 150, 180, 260 | Straight, angled, J-tip, long taper | Precise torque control, superior visibility, small vessel option (0.018 inch) diameter |
| Boston Scientific Corporation | Enroute 0.014-inch Guidewire | Stainless steel with hydrophilic coating | 0.014 | 95 | Shapeable, 5-cm radiopaque tip | Designed for navigating tortuous short vessel segments with its unique combination of short length, short taper, and a shapeable tip; excellent torque control and device deliverability |
Wires / Mandril/Specialty Guidewires
View Chart| Company Name | Product Name | Type | Diameter (inch) | Length (cm) | Tip Type | Coating Type | Comments |
|---|---|---|---|---|---|---|---|
| Boston Scientific Corporation | V-14 ControlWire Guidewire | Scitanium stainless steel core, polymer sleeve | 0.014 | 182, 300 | Straight, angled (shapeable) | ICE hydrophilic coating on distal end | Distal radiopaque section (distal: 2 cm); single-piece core with torque jacket for 1:1 torque control; shapeable tip intended to facilitate accurate placement; proximal PTFE jacket intended to provide firm support and low friction surface |
| Boston Scientific Corporation | V-18 ControlWire Steerable Guidewire | Scitanium stainless steel core, polymer sleeve | 0.018 | 110, 150, 200, 300 | Straight (shapeable) | ICE hydrophilic coating on distal end | Hydrophilic performance and excellent torque control designed for distal, peripheral access and contralateral approaches; single-piece core with torque jacket for 1:1 torque control; robust shapeable 3-cm tip intended to facilitate accurate placement; proximal PTFE jacket intended to provide firm support and low friction surface |
| Boston Scientific Corporation | Victory Guidewire | Stainless steel core, polymer sleeve | 0.014, 0.018 | 195, 300 | Straight (shapeable) | 35-cm hydrophilic coating on distal end | 12-, 18-, 25-, and 30-gauge tip loads designed to cross highly resistant lesions; excellent torque control designed for distal, peripheral access |
Other Devices / Ablation Devices
View Chart| Company Name | Product Name | Technology (RF, Microwave, Cryo, IRE) | Ex Vivo Ablation Zone | In Vivo Ablation Zone | Antenna/Electrode Length (cm) | Antenna Gauge | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|
| Boston Scientific Corporation | IceFORCE 2.1 CX 90° Cryoablation Needle | Cryo | – | 32- X 49-mm single needle; -20°C ablation zone (37°C gel model) | 17.5 | 14 | The needles are used with the Boston Scientific Cryoablation Systems and are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | IceFORCE 2.1 CX L 90° Cryoablation Needle | Cryo | – | 32- X 49-mm single needle; -20°C ablation zone (37°C gel model) | 23 | 14 | The needles are used with the Boston Scientific Cryoablation Systems and are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | IceFORCE 2.1 CX Straight Cryoablation Needle | Cryo | – | 32- X 49-mm single needle; -20°C ablation zone (37°C gel model) | 17.5 | 14 | The needles are used with the Boston Scientific Cryoablation Systems and are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | ICEfx Cryoablation System | Cryo | – | – | – | – | Indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology and urology; this system is designed to destroy tissue (including prostate and kidney tissue, liver metastases, tumors, skin lesions) by the application of extremely cold temperatures; a full list of specific indications can be found in the product's user manual |
| Boston Scientific Corporation | IcePearl 2.1 CX 90º Cryoablation Needle | Cryo | – | 27- X 32-mm single needle; -20°C ablation zone (37°C gel model) | 17.5 | 14 | The needles are used with the Boston Scientific Cryoablation Systems and are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | IcePearl 2.1 CX L 90° Cryoablation Needle | Cryo | – | 27- X 32-mm single needle; -20°C ablation zone (37°C gel model) | 23 | 14 | The needles are used with the Boston Scientific Cryoablation Systems and are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | IcePearl 2.1 CX Straight Cryoablation Needle | Cryo | – | 27- X 32-mm single needle; -20°C ablation zone (37°C gel model) | 17.5 | 14 | The needles are used with the Boston Scientific Cryoablation Systems and are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | IceRod 1.5 CX 90° Cryoablation Needle | Cryo | – | 26- X 45-mm single needle; -20°C ablation zone (37°C gel model) | 17.5 | 17 | The needles are used with the Boston Scientific Cryoablation Systems and are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | IceRod 1.5 MRI 90° Cryoablation Needle | Cryo | – | 28- X 49-mm single needle; -20°C ablation zone (21°C gel model) | 17.5 | 17 | The needles are intended for cryoablative destruction of tissue during surgical procedures; the 1.5 MRI Cryoablation Needles, used with a Boston Scientific MRI Cryoablation System, are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | IceRod 1.5 MRI Straight Cryoablation Needle | Cryo | – | 28- X 49-mm single needle; -20°C ablation zone (21°C gel model) | 17.5 | 17 | The needles are intended for cryoablative destruction of tissue during surgical procedures; the 1.5 MRI Cryoablation Needles, used with a Galil Medical MRI Cryoablation System, are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | IceRod 1.5 Straight Cryoablation Needle | Cryo | – | 25- X 45-mm single needle; -20°C ablation zone (37°C gel model) | 17.5 | 17 | The needles are used with the Boston Scientific Cryoablation Systems and are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | IceSeed 1.5 90° Cryoablation Needle | Cryo | – | 23- X 32-mm single needle; -20°C ablation zone (21°C gel model) | 17.5 | 17 | The needles are used with the Boston Scientific Cryoablation Systems and are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | IceSeed 1.5 CX Cryoablation Needle | Cryo | -- | 24 X 28 mm single needle; -20ºC ablation zone (37º C gel model) | 17.5 | 17 | The needles are used with the Boston Scientific Cryoablation Systems and are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | IceSeed 1.5 CX Short Cryoablation Needle | Cryo | -- | 21 X 26 mm single needle; -20ºC ablation zone (37ºC gel model) | 10 | 17 | The needles are used with the Boston Scientific Cryoablation Systems and are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | IceSeed 1.5 MRI 90° Cryoablation Needle | Cryo | – | 15- X 20-mm single needle; -20°C ablation zone (37°C gel model) | 17.5 | 17 | The needles are intended for cryoablative destruction of tissue during surgical procedures; the 1.5 MRI Cryoablation Needles, used with a Boston Scientific MRI Cryoablation System, are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | IceSeed 1.5 MRI Straight Cryoablation Needle | Cryo | – | 23- X 32-mm single needle; -20°C ablation zone (21°C gel model) | 17.5 | 17 | The needles are intended for cryoablative destruction of tissue during surgical procedures; the 1.5 MRI Cryoablation Needles, used with a Boston Scientific MRI Cryoablation System, are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | IceSeed 1.5 Straight Cryoablation Needle | Cryo | – | 15- X 20-mm single needle; -20°C ablation zone (37°C gel model) | 17.5 | 17 | The needles are used with the Boston Scientific Cryoablation Systems and are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | IceSphere 1.5 90° Cryoablation Needle | Cryo | - | 23- X 29-mm single needle; -20°C ablation zone (37°C gel model) | 17.5 | 17 | The needles are used with the Boston Scientific Cryoablation Systems and are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | IceSphere 1.5 CX 90° Cryoablation Needle | Cryo | – | 23- X 29-mm single needle; -20°C ablation zone (37°C gel model) | 17.5 | 17 | The needles are used with the Boston Scientific Cryoablation Systems and are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | IceSphere 1.5 S 90° Cryoablation Needle | Cryo | – | 23- X 29-mm single needle; -20°C ablation zone (37°C gel model) | 10 | 17 | The needles are used with the Boston Scientific Cryoablation Systems and are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | IceSphere 1.5 Straight Cryoablation Needle | Cryo | – | 23- X 29-mm single needle -20°C ablation zone (37°C gel model) | 17.5 | 17 | The needles are used with the Boston Scientific Cryoablation Systems and are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | LeVeen CoAccess Electrode System | RF | Individual probes offered with burn diameters of 3, 3.5, and 4 cm | 3, 3.5, 4 cm | 15, 25 | 15, 16.5 | Ablation of soft tissue |
| Boston Scientific Corporation | LeVeen Needle Electrode | RF | Individual probes offered with burn diameters of 3, 3.5, 4, and 5 cm | 3, 3.5, 4, 5 cm | 12, 15, 25 | 13, 14, 15 | Ablation of soft tissue |
| Boston Scientific Corporation | LeVeen Superslim Needle Electrode | RF | Individual probes offered with burn diameters of 2 and 3 cm | 2, 3 cm | 15, 25 | 17 | Ablation of soft tissue |
| Boston Scientific Corporation | Soloist Electrode | RF | Single needle, nonarray probe with burn diameter of 1 cm | 1 cm | 18 | 16.5 | Ablation of soft tissue |
| Boston Scientific Corporation | Visual ICE Cryoablation System | Cryo | – | – | – | – | Indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology; this system is designed to destroy tissue (including prostate and kidney tissue, liver metastases, tumors, skin lesions) by the application of extremely cold temperatures; a full list of specific indications can be found in the system's user manual |
| Boston Scientific Corporation | Visual ICE MRI Cryoablation System | Cryo | – | – | – | – | Indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology; this system is designed to destroy tissue (including prostate and kidney tissue, liver metastases, tumors, skin lesions) by the application of extremely cold temperatures; a full list of specific indications can be found in the system's user manual |
| Boston Scientific Corporation | IceRod 1.5 CX Straight Cryoablation Needle | Cryo | – | 26- X 45-mm single needle; -20ºC ablation zone (37ºC gel model) | 17.5 | 17 | The needles are used with the Boston Scientific Cryoablation Systems and are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | IceSeed 1.5 CX 90º Cryoablation Needle | Cryo | – | 20- X 26-mm single needle; -20ºC ablation zone (37ºC gel model) | 17.5 | 17 | The needles are used with the Boston Scientific Cryoablation Systems and are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | IceSeed 1.5 CX 90º S Cryoablation Needle | Cryo | – | 18- X 24-mm single needle; -20ºC ablation zone (37ºC gel model) | 17.5 | 17 | The needles are used with the Boston Scientific Cryoablation Systems and are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | IceSeed 1.5 CX Straight Cryoablation Needle | Cryo | – | 20- X 26-mm single needle; -20ºC ablation zone (37ºC gel model) | 17.5 | 17 | The needles are used with the Boston Scientific Cryoablation Systems and are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
| Boston Scientific Corporation | IceSphere 1.5 CX Straight Cryoablation Needle | Cryo | – | 23- X 29-mm single needle; -20ºC ablation zone (37ºC gel model) | 17.5 | 17 | The needles are used with the Boston Scientific Cryoablation Systems and are indicated for use as a cryosurgical tool in the fields of general surgery, dermatology, neurology (including cryoanalgesia), thoracic surgery (with the exception of cardiac tissue), ENT, gynecology, oncology, proctology, and urology |
Other Devices / Atherectomy Devices
View Chart| Company Name | Product Name | Minimum Vessel Diameter (mm) | Sheath Compatibility (F) | Crossing Profile (inch) | Working Length (cm) | Tip Length (cm) |
|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Jetstream SC 1.6 mm | 2.5 | 7 | 0.063 (1.6 mm) | 145 | – |
| Boston Scientific Corporation | Jetstream SC 1.85 mm | 2.75 | 7 | 0.073 (1.85 mm) | 145 | – |
| Boston Scientific Corporation | Jetstream XC 2.1/3.0 mm | Blades down: 3; blades up: 4 | 7 | Blades down: 0.083 (2.1 mm); blades up: 0.118 (3 mm) | 135 | – |
| Boston Scientific Corporation | Jetstream XC 2.4/3.4 mm | Blades down: 3.5; blades up: 4.5 | 7 | Blades down: 0.094 (2.4 mm); blades up: 0.134 (3.4 mm) | 120 | – |
| Boston Scientific Corporation | Peripheral RotaLink Plus, 1.25 mm | 1.5 | 5 | 0.049 | 135 | – |
| Boston Scientific Corporation | Peripheral RotaLink Plus, 1.50 mm | 1.8 | 5 | 0.059 | 135 | – |
| Boston Scientific Corporation | Peripheral RotaLink Plus, 1.75 mm | 2.1 | 6 | 0.069 | 135 | – |
| Boston Scientific Corporation | Peripheral RotaLink Plus, 2.00 mm | 2.4 | 7 | 0.079 | 135 | – |
| Boston Scientific Corporation | Peripheral RotaLink Plus, 2.25 mm | 2.7 | 7 | 0.089 | 135 | – |
| Boston Scientific Corporation | Peripheral RotaLink Plus, 2.50 mm | 3 | 8 | 0.098 | 135 | – |
| Boston Scientific Corporation | Peripheral Rotapro Pre-Connected Burr and Advancing Device, 1.25 mm | 1.5 | 4, 5 | 0.049 | 135 | – |
| Boston Scientific Corporation | Peripheral Rotapro Pre-Connected Burr and Advancing Device, 1.50 mm | 1.8 | 5 | 0.059 | 135 | – |
| Boston Scientific Corporation | Peripheral Rotapro Pre-Connected Burr and Advancing Device, 1.75 mm | 2.1 | 6 | 0.069 | 135 | – |
| Boston Scientific Corporation | Peripheral Rotapro Pre-Connected Burr and Advancing Device, 2.00 mm | 2.4 | 6, 7 | 0.079 | 135 | – |
| Boston Scientific Corporation | Peripheral Rotapro Pre-Connected Burr and Advancing Device, 2.25 mm | 2.7 | 7 | 0.089 | 135 | – |
| Boston Scientific Corporation | Peripheral Rotapro Pre-Connected Burr and Advancing Device, 2.50 mm | 3.0 | 7, 8 | 0.098 | 135 | – |
Other Devices / Embolic Protection Devices
View Chart| Company Name | Product Name | Type | Position | US FDA Indicated Use |
|---|---|---|---|---|
| Boston Scientific Corporation | FilterWire EZ Embolic Protection System | Filter | Distal | Indicated for use as a guidewire and EPS to contain and remove embolic material (thrombus/debris) while performing angioplasty and stenting procedures in coronary saphenous vein bypass grafts and carotid arteries; the diameter of the vessel at the site of filter loop placement should be between 2.25–5.5 mm for coronary saphenous vein bypass graft procedures and between 3.5–5.5 mm for carotid procedures |
| Boston Scientific Corporation | Enroute Transcarotid Neuroprotection System | Robust flow reversal | Proximal | Intended to provide transcarotid vascular access, introduction of diagnostic agents and therapeutic devices, and embolic protection during carotid artery angioplasty and stenting procedures for patients diagnosed with carotid artery stenosis and who have the appropriate anatomy described below: adequate femoral venous access, common carotid artery reference diameter of at least 6 mm, carotid bifurcation is a minimum of 5 cm above the clavicle as measured by duplex Doppler ultrasound or computerized axial tomography angiography or magnetic resonance angiography |
Other Devices / Endovenous Ablation
View Chart| Company Name | Product Name | Technology | Wavelength (nm) | Sheath Sizes (F) | Sheath Lengths (cm) | US FDA Indicated Use |
|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Varithena (Polidocanol Injectable Foam) 1% | Polidocanol injectable foam (endovenous chemical ablation) | – | – | – | Treatment of incompetent great saphenous veins, accessory saphenous veins, and visible varicosities of the great saphenous vein system above and below the knee; improves the symptoms of superficial venous incompetence and the appearance of visible varicosities; see https://www.bostonscientific.com/en-US/products/vein-ablation/varithena.html for important safety information |
Other Devices / Inflation Devices
View Chart| Company Name | Product Name | Color | Pressure Range (atm) | Barrel Volume (mL) | Luminescent Gauge (Yes/No) | Gauge | Latch Type | Threads |
|---|---|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Encore 26 Inflation Device | Teal, yellow | 0–26 | 20 | No | Angled/inline | Lock/squeeze | 13/inch, engaged |
| Boston Scientific Corporation | Encore 40 Inflation Device | Clear | 0–40 | 25 | Yes | Flat | Quick latch | – |
Other Devices / Intravascular Ultrasound
View Chart| Company Name | Product Name | Imaging Diameter (mm) | Catheter Usable Length (cm) | Maximum Guidewire (inch) | Minimum Guide Catheter ID (F) | Shaft Distal Section (F) | Minimum Sheath Diameter (F) | Comments |
|---|---|---|---|---|---|---|---|---|
| Boston Scientific Corporation | OptiCross18 | Up to 22 (when the catheter is centered to the vessel) | 135 | 0.018 | – | 3.6 | 2 | – |
| Boston Scientific Corporation | OptiCross35 | Up to 70 (when the catheter is centered to vessel) | 105 | 0.035 | 8 | 8 | 8 | – |
Other Devices / Mechanical Thrombectomy/Thrombolysis (Peripheral/Venous)
View Chart| Company Name | Product Name | Sheath Compatibility (F) | Guidewire Compatibility (inch) | Working Length (cm) | Mode of Operation | US FDA Indicated Use |
|---|---|---|---|---|---|---|
| Boston Scientific Corporation | AngioJet AVX Thrombectomy Catheter | 6 | 0.035 | 50 | High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal | Breaking apart and removing thrombus from AV access conduits ≥ 3 mm in diameter |
| Boston Scientific Corporation | AngioJet Solent Dista Thrombectomy Catheter | 4 | 0.014 | 145 | High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal | Breaking apart and removing thrombus from upper and lower extremity peripheral arteries ≥ 1.5 mm in diameter and for use with the AngioJet Ultra Power Pulse Kit for the control and selective infusion of physician specified fluids, including thrombolytic agents, into the peripheral vascular system |
| Boston Scientific Corporation | AngioJet Solent Omni Thrombectomy Catheter | 6 | 0.035 | 120 | High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal | Breaking apart and removing thrombus from upper and lower extremity peripheral arteries, upper extremity peripheral veins, iliofemoral and lower extremity peripheral veins ≥ 3 mm in diameter, and for use with the AngioJet Ultra Power Pulse Kit for the control and selective infusion of physician specified fluids, including thrombolytic agents, into the peripheral vascular system |
| Boston Scientific Corporation | AngioJet Solent Proxi Thrombectomy Catheter | 6 | 0.035 | 90 | High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal | Breaking apart and removing thrombus from upper and lower extremity peripheral arteries, upper extremity peripheral veins, iliofemoral and lower extremity peripheral veins ≥ 3 mm in diameter, and for use with the AngioJet Ultra Power Pulse Kit for the control and selective infusion of physician specified fluids, including thrombolytic agents, into the peripheral vascular system |
| Boston Scientific Corporation | AngioJet ZelanteDVT Thrombectomy Catheter | 8 | 0.035 | 105 | High-velocity water jets enclosed in catheter utilize the Bernoulli principle for capture, microfragmentation, and removal | The ZelanteDVT Thrombectomy System, which includes the ZelanteDVT Thrombectomy Set and the ClotHunter Helical Rotation Device, is intended for use with the AngioJet Ultra Console to break apart and remove thrombus, including deep vein thrombus (DVT), from (1) iliofemoral and lower extremity veins ≥ 6 mm in diameter and (2) upper extremity peripheral veins ≥ 6 mm in diameter; the ZelanteDVT Thrombectomy System is also intended for use with the AngioJet Ultra Power Pulse technique for the controlled and selective infusion of physician-specified fluids, including thrombolytic agents, into the peripheral vascular system |
| Boston Scientific Corporation | Ekos Endovascular System | 6 | 0.035 | 106 (treatment areas: 6, 12, 18, 24, 30, 40, 50); 135 (treatment areas: 12, 30, 40, 50) | The treatment offers a minimally invasive system for the acceleration of thrombus dissolution; the ultrasonic core generates a localized acoustic field that targets the entire thrombus; this greatly accelerates lytic dispersion by driving the drug deeper into the clot and unwinding the fibrin to expose plasminogen receptor sites | Indicated for the ultrasound-facilitated, controlled, and selective infusion of physician-specified fluids, including thrombolytics, into the vasculature for the treatment of pulmonary embolism and/or deep vein thrombosis; the controlled and selective infusion of physician-specified fluids, including thrombolytics, into the peripheral vasculature; and the infusion of solutions into the pulmonary arteries |
| Boston Scientific Corporation | Ekos+ Endovascular System | 8 | 0.035 | 106 (treatment areas: 8, 12, 16, 20); 135 (treatment areas: 8, 12, 16, 20) | The treatment offers a minimally invasive system for the acceleration of thrombus dissolution; the ultrasonic core generates a localized acoustic field that targets the entire thrombus; this greatly accelerates lytic dispersion by driving the drug deeper into the clot and unwinding the fibrin to expose plasminogen receptor sites | Indicated for the ultrasound-facilitated, controlled, and selective infusion of physician-specified fluids, including thrombolytics, into the vasculature for the treatment of pulmonary embolism and/or deep vein thrombosis; the controlled and selective infusion of physician-specified fluids, including thrombolytics, into the peripheral vasculature; and the infusion of solutions into the pulmonary arteries |
| Boston Scientific Corporation | SmartClawThrombectomy Catheter | 8 | 0.035 | 145 | An expandable basket loosens and removes thrombus | Indicated for the nonsurgical removal of thrombi and emboli from the peripheral vasculature |
Other Devices / Selective Internal Radiation Therapy
View Chart| Company Name | Product Name | Material | Radioactive Isotope | Microsphere Diameter (µm) | Specific Gravity (g/mL) | Microspheres Per Vial (million) | Activity per Vile (GBq) | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|---|
| Boston Scientific Corporation | TheraSphere Y-90 Glass Microspheres | Glass | Y-90 (integral to the glass matrix) | 25 ± 10 | 3.3 | Approximately 0.25 million per GBq at calibration (3 GBq vial contains approximately 0.75 million microspheres) | Standard dose sizes: 3, 5, 7, 10, 15, 20; custom dose sizes: available in 0.5 increments, between 3–20 (activity/microsphere at calibration is approximately 4,000 Bq) | Indicated for use in radiation treatment or as a neoadjuvant to surgery or transplantation in patients with unresectable hepatocellular carcinoma who can have placement of appropriately positioned hepatic arterial catheters; also indicated for hepatocellular carcinoma patients with partial or branch portal vein thrombosis/occlusion, when clinical evaluation warrants the treatment |
Embolization / Conformable Embolics
View Chart| Company Name | Product Name | Composition | Material Description | Volume (mL) | Minimum Catheter ID (inch) | Maximum Vessel Size (mm) | US FDA Indicated Use |
|---|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Obsidio Conformable Embolic | Premixed embolic agent consisting of prehydrated resorbable porcine gelatin, layered silicate, and tantalum powder (to provide contrast for visualization under fluoroscopy) | Obsidio syringe | 1 | 0.024 (0.62 mm) | 3 | Indicated for use in the embolization of hypervascular tumors and blood vessels to occlude flow for controlling bleeding/hemorrhaging in the peripheral vasculature |
Aortic (AAA) / Occlusion/Molding Balloons
View Chart| Company Name | Product Name | Size (F) | Recommended Introducer Size (F) | Guidewire Compatibility (inch) | Catheter Length (cm) | Maximum Inflated Balloon Diameter (mm) |
|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Berenstein Occlusion Balloon Catheter | 6 | 8 (2.7 mm) | 0.038 | 80 | 8.5, 11.5 |
| Boston Scientific Corporation | Equalizer Balloon Catheter | 7 | 14 (20–27 mm), 16 (33 mm), N/A (40 mm) | 0.038 | 65, 100 | 20, 27, 33, 40 |
| Boston Scientific Corporation | Standard Occlusion Balloon Catheter | 7 | 9 (3 mm) | 0.038 | 65, 100 | 11.5 |
Aortic (TAA) / Occlusion/Molding Balloons
View Chart| Company Name | Product Name | Size (F) | Recommended Introducer Size (F) | Guidewire Compatibility (inch) | Catheter Length (cm) | Maximum Inflated Balloon Diameter (mm) |
|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Equalizer Balloon Catheter | 7 | 14 (20–27 mm), 16 (33 mm), N/A (40 mm) | 0.038 | 65, 100 | 20, 27, 33, 40 |
Catheters / Microcatheters
View Chart| Company Name | Product Name | Type of Catheter Construction | Proximal Size (F) | Middle Size (F) | Distal Size (F) | Catheter Working Length (cm) | Catheter Endhole Diameter ID (inch) | Recommended Guidewire Size (inch) | Radiopaque Tip (Yes/No) | Hydrophilic Coating (Yes/No) |
|---|---|---|---|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Direxion Fathom-16 System Preloaded Torqueable Microcatheter | Steerable laser-cut nitinol shaft | 2.7 | – | 2.4 | 105, 130, 155 | 0.021 | Includes preloaded Fathom-16 guidewire | Yes | Yes |
| Boston Scientific Corporation | Direxion Hi-Flo Fathom-16 System Preloaded Torqueable Microcatheter | Steerable laser-cut nitinol shaft | 3 | – | 2.8 | 105, 130, 155 | 0.027 | Includes preloaded Fathom-16 guidewire | Yes | Yes |
| Boston Scientific Corporation | Direxion Hi-Flo Torqueable Microcatheter | Steerable laser-cut nitinol shaft | 3 | – | 2.8 | 105, 130, 155 | 0.027 | 0.021 (maximum) | Yes | Yes |
| Boston Scientific Corporation | Direxion Hi-Flo Transend-18 System Preloaded Torqueable Microcatheter | Steerable laser-cut nitinol shaft | 3 | – | 2.8 | 105, 130, 155 | 0.027 | Includes preloaded Transend-18 guidewire | Yes | Yes |
| Boston Scientific Corporation | Direxion Torqueable Microcatheter | Steerable laser-cut nitinol shaft | 2.7 | – | 2.4 | 105, 130, 155 | 0.021 | 0.018 (maximum) | Yes | Yes |
| Boston Scientific Corporation | Direxion Transend-14 System Preloaded Torqueable Microcatheter | Steerable laser-cut nitinol shaft | 2.7 | – | 2.4 | 105, 130, 155 | 0.021 | Includes preloaded Transend-14 guidewire | Yes | Yes |
| Boston Scientific Corporation | Renegade Hi-Flo Fathom Preloaded System | Vortec fiber and platinum braid | 3 | – | 2.8 | 105, 115, 135, 150 | 0.027 | Includes preloaded Fathom-16 guidewire | Yes | Yes |
| Boston Scientific Corporation | Renegade Hi-Flo Microcatheter | Vortec fiber and platinum braid | 3 | – | 2.8 | 105, 115, 135, 150 | 0.027 | 0.018 (maximum) | Yes | Yes |
| Boston Scientific Corporation | Renegade Hi-Flo Transend Kit | Vortec fiber and platinum braid | 3 | – | 2.8 | 105, 115, 135 | 0.027 | Includes Transend-18 guidewire | Yes | Yes |
| Boston Scientific Corporation | Renegade Microcatheter | Vortec fiber braid | 3 | – | 2.5 | 130, 150 | 0.021 | 0.018 (maximum) | Yes | Yes |
| Boston Scientific Corporation | Renegade STC 18 Microcatheter | Vortec fiber and stainless steel braid | 3 | – | 2.4 | 105, 130, 150 | 0.021 | 0.018 (maximum) | Yes | Yes |
| Boston Scientific Corporation | TruSelect Microcatheter | Tungsten wire braided layer | 2.8 | – | 2 | 105, 130, 155, 175 | 0.021 | 0.016 (maximum) | Yes | Yes |
Embolization / Embolic Particles/Beads
View Chart| Company Name | Product Name | Composition | Type | Sizes (µm) | Color Coding | US FDA Indicated Use |
|---|---|---|---|---|---|---|
| Boston Scientific Corporation | Contour Embolization Particles | PVA particles | Irregularly shaped flakes | 45–150, 150–250, 250–355, 355–500, 500–710, 710–1,000, 1,000–1,180 | Labels are color-coded by particle size | Embolization of peripheral hepatic vascular tumors, including leiomyoma, uteri, and peripheral AVMs |
| Boston Scientific Corporation | LC Bead | Biocompatible, sulphonate-modified, N-Fil hydrogel | Spherical shape | 100–300, 300–500 | Vial labels are color-coded by particle size | Embolization of hypervascular tumors and arteriovenous malformations (AVMs) |
| Boston Scientific Corporation | LC Bead LUMI | Biocompatible polyvinyl alcohol hydrogel beads containing a covalently bound radiopaque moiety | Spherical shape | 40–90, 70–150 | Vial labels are color-coded by particle size | Embolization of hypervascular tumors and arteriovenous malformations (AVMs) |
| Boston Scientific Corporation | LC Bead M1 | Biocompatible, sulphonate-modified, N-Fil hydrogel | Spherical shape | 70–150 | Vial labels are color-coded by particle size | Embolization of hypervascular tumors and arteriovenous malformations (AVMs) |
More Categories:
Aortic (AAA) Aortic (TAA) Balloons Catheters Embolization Sheaths Stents Wires Other Devices View AllAdvertisement